• Title/Summary/Keyword: Error level

Search Result 2,511, Processing Time 0.042 seconds

Development and Evaluation of Stitching Algorithm With five Degrees of Freedom for Three-dimensional High-precision Texture of Large Surface (대면적/고정밀 3차원 표면형상의 5자유도 정합법 개발 및 평가)

  • Lee, Dong-Hyeok;Ahn, Jung-Hwa;Cho, Nham Gyoo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.118-126
    • /
    • 2014
  • In this paper, a new method is proposed for the five-degree-of-freedom precision alignment and stitching of three-dimensional surface-profile data sets. The control parameters for correcting thealignment error are calculated from the surface profile data for overlapped areas among the adjacent measuring areas by using the "least squares method" and "maximum lag position of cross correlation function." To ensure the alignment and stitching reliability, the relationships betweenthe alignment uncertainty, overlapped area, and signal-to-noise level of the measured profile data are investigated. Based on the results of this uncertainty analysis, an appropriate size is proposed for the overlapped area according to the specimen's surface texture and noise level.

Reliability Estimation of Series-Parallel Systems Using Component Failure Data (부품의 고장자료를 이용하여 직병렬 시스템의 신뢰도를 추정하는 방법)

  • Kim, Kyung-Mee O.
    • IE interfaces
    • /
    • v.22 no.3
    • /
    • pp.214-222
    • /
    • 2009
  • In the early design stage, system reliability must be estimated from life testing data at the component level. Previously, a point estimate of system reliability was obtained from the unbiased estimate of the component reliability after assuming that the number of failed components for a given time followed a binomial distribution. For deriving the confidence interval of system reliability, either the lognormal distribution or the normal approximation of the binomial distribution was assumed for the estimator of system reliability. In this paper, a new estimator is used for the component level reliability, which is biased but has a smaller mean square error than the previous one. We propose to use the beta distribution rather than the lognormal or approximated normal distribution for developing the confidence interval of the system reliability. A numerical example based on Monte Carlo simulation illustrates advantages of the proposed approach over the previous approach.

Design of Rogowski coil to improve of current measurement sensitivity (전류측정감도 개선을 위한 로고우스키 코일의 설계)

  • Park, J.N.;Lee, C.;Jang, Y.M.;Kang, S.H.;Lim, K.J.;Na, D.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.609-612
    • /
    • 2001
  • Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents. and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore. geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error was examined as well. In the results, the source of error was associated with coil designs. i.e. shape and uniformity of coil and a geometrical location of current source inside and outside of the Rogowski coil.

  • PDF

Limit of the maximum Signal Levels from other Radio Noise and interference of the Reciving Signal (외부잡음의 수신신호에 미치는 영향과 최악조건의 한계)

  • 김원후
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.5 no.1
    • /
    • pp.34-39
    • /
    • 1980
  • This paper discribes a effect of Radio signals in Noise and Interference for the Communication systems and Generation of diffusion Noise from the Solid state Devices, and in Jection it to the Radio Reciving systems for probability of Signal Detection. The error performance depends on level of the Noise spectral density by Random processes between average signal energy. This experimental result are given by the performance of the correlation receiver for detecting Completely known signals in additive white Gaussian Noise.

  • PDF

A determination of economic control limits considering process deterioration (공정의 열화를 고려한 경제적 관리한계 결정)

  • 심윤보;김성집
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.45
    • /
    • pp.237-246
    • /
    • 1998
  • In most statistical process control(SPC), control charts are used in which samples are taken and a suitable statistic is determined and plotted. In these control charts, control limits, ${\mu}{\pm}textsc{k{\sigma}}$, from which a decision is made are mostly ${\mu}{\pm}3{\sigma}$ and current literature in control charts are mainly concerned with detecting a shift in the mean. Therefore, when $\sigma$ is increased considerably after a long time, using control limits set at the first time causes a great deal of economic loss. In this paper the solutions to determine new control limits which maximizes the profit per unit produced and reduce $\sigma$ to economically optimal level for a certain cost when $\sigma$ is increased due to process deterioration are proposed. By applying new control limits, $\alpha$ error decreases considerably compared to apply initial control limits when $\sigma$ is increased due to process deterioration. Therefore, false alarm investigation cost drops down to the level of initial a error. And also this solution provides useful information regarding replacement of a process when the process is reviewed regularly.

  • PDF

Design of Rogowski coil to improve of current measurement sensitivity (전류측정감도 개선을 위한 로고우스키 코일의 설계)

  • Park, J. N.;Lee, C.;Jang, Y. M.;Kang, S. H.;Lim, K. J.;Na, D. H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.609-612
    • /
    • 2001
  • Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents, and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore, geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error wa examined as well. n the results, the source of error was associated with coil designs, i.e. shape and uniformity of coil and a geometrical location of current source inside and outside of the Rogowski coil.

  • PDF

Development of Single-phase Fuzzy TPR for temperature control (온도제어를 위한 단상용 Fuzzy TPR 개발에 관한 연구)

  • Hong, Sung-Hun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1053-1055
    • /
    • 1996
  • This paper proposes a Fuzzy TPR having the control function to a TPR used for the conversion of electricity in industrial field. The Fuzzy TPR based on the Fuzzy Logic Control technique is composed of the parts to calculate the low-level value and the high-level value. These values are calculated by error and change in error which are refer to the look-up table. To show the usefulness of the proposed Fuzzy TPR, it is applied to industrial temperature control system. In the results of experiment, we see that the system is able to fast reach steady-state, and for our approach to be robust to external disturbance than the method using the conventional TPR.

  • PDF

Verification of Logic Gate Interconnection (논리회로 상호간의 연결도 검증)

  • Jung, Ja Choon;Kyung, Chong Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.338-346
    • /
    • 1987
  • This paper describes a method for verifying whether a given geometrical layout correcdtly reflects the original logic level description. The logic description extracted from layout data was directly compadred with the original logic diagram generated at logic level design stage where the logic diagram is represented as a weighted multi-place graph. The comparison is based on graph isomorphism and error messages(error categories and locations)are invoked if any difference is found between the two logic descriptions. An efficient partitioning algorithm which consists of two steps, candidate selection and equal weight partitioning procedure, enables the entire verification process to occur in O(n log n) time.

  • PDF

Prediction of Water Level at Downstream Site by Using Water Level Data at Upstream Gaging Station (상류 수위관측소 자료를 활용한 하류 지점 수위 예측)

  • Hong, Won Pyo;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, the overseas construction market has been actively promoted for about 10 years, and overseas dam construction has been continuously performed. For the economic and safe construction of the dam, it is important to prepare the main dam construction plan considering the design frequency of the diversion tunnel and the cofferdam. In this respect, the prediction of river level during the rainy season is significant. Since most of the overseas dam construction sites are located in areas with poor infrastructure, the most efficient and economic method to predict the water level in dam construction is to use the upstream water level. In this study, a linear regression model, which is one of the simplest statistical methods, was proposed and examined to predict the downstream level from the upstream level. The Pyeongchang River basin, which has the characteristics of the upper stream (mountain stream), was selected as the target site and the observed water level in Pyeongchang and Panwoon gaging station were used. A regression equation was developed using the water level data set from August 22th to 27th, 2017, and its applicability was tested using the water level data set from August 28th to September 1st, 2018. The dependent variable was selected as the "level difference between two stations," and the independent variable was selected as "the level of water level in Pyeongchang station two hours ago" and the "water level change rate in Pyeongchang station (m/hr)". In addition, the accuracy of the developed equation was checked by using the regression statistics of Root Mean Square Error (RMSE), Adjusted Coefficient of Determination (ACD), and Nach Sutcliffe efficiency Coefficient (NSEC). As a result, the statistical value of the linear regression model was very high, so the downstream water level prediction using the upstream water level was examined in a highly reliable way. In addition, the results of the application of the water level change rate (m/hr) to the regression equation show that although the increase of the statistical value is not large, it is effective to reduce the water level error in the rapid level rise section. Accordingly, this is a significant advantage in estimating the evacuation water level during main dam construction to secure safety in construction site.

A Small Area Estimation for Monthly Wage Using Mean Squared Percentage Error (MSPE를 이용한 임금총액 소지역 추정)

  • Hwang, Hee-Jin;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.2
    • /
    • pp.403-414
    • /
    • 2009
  • Many researches have been devoted to the small area estimation related with the area level statistics. Almost all of the small area estimation methods are derived based on minimization of mean squared error(MSE). Recently Hwang and Shin (2008) suggested an alternative small area estimation method by minimizing mean squared percentage error. In this paper we apply this small area estimation method to the labor statistics, especially monthly wages by a branch area of labor department. The Monthly Labor Survey data (2007) is used for analysis and comparison of these methods.