• Title/Summary/Keyword: Error Counter

Search Result 124, Processing Time 0.025 seconds

Development of Automatic Welding Machine and Weld-Quality Improvement for Automobile Parts (자동차부품 용접자동화장치 개발 및 용접품질 개선에 관한 연구)

  • Kim, Kyo-Hyoung;Lee, Ki-Sul;Lee, Taik-Soon;Joo, Hae-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.1
    • /
    • pp.63-73
    • /
    • 1990
  • Low cost automatic welding machine is developed for the purpose of welding process automation of automobile parts with two dimensional welding joints. Developed gantry type machine is equipped with X, Y and roll axis stepping motors, and dirive units units are designed by two phase on drive scheme using shift registers. Control system is constructed by single board microcomputer of Z80A CPU, and also it is equipped with parallel input output ports and counter-timer chips. Linear and circular interpolation of welding head movement is accomplished by employing software digital differential analyzers. It has been shown that contour error of develped system is withi ${\pm}1.0mm$, meaning that the machine is suitable for CO2 arc welding process of automoble parts and is expected it's application to industry.

  • PDF

Heat and Mass Transfer Analysis of Phosphoric Acid Fuel Cell According to Variation of gas Flow passage (인산형 연료전지의 가스유로방향 변화에 따른 열 및 물질전달해석)

  • 전동협;정영식;채재우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1338-1346
    • /
    • 1994
  • The objective of this study is to investigate the effect of various parameters, such as temperature, mean current density and voltage on the performance of phosphoric acid fuel cell (PAFC) by numerical analysis. Two types of flow passages, which are Z-parallel type and Z-counter type, are evaluated to obtain the best current density and temperature distribution. Parametric studies and sensitivity analysis of the PAFC system's operation in single cell are accomplished. A steady state simulation of the entire system is developed using nonlinear ordinary differential equations. The finite difference method and trial and error procedures are used to obtain a solution.

A Study on the Construction of LDV System for a Measurement of the Fluid Velocity (유체속도 측정을 위한 레이저 도플러 유속계의 구성에 관한 연구)

  • 최종원;조재흥;정명세
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.5
    • /
    • pp.361-369
    • /
    • 1991
  • The optics and the signal processor of dual beam laser Doppler velocimeter(LDV) was fabricated. By using the dual beam and the forward scattering, the optics part of LDV was fabricated. And the signal processor of LDV was designed by the frequency counter type using new 11:6 period timing device in order to remove error signals, and was made of the reference clock of a 500 MHz ECL oscillator. Doppler frequencies from 10KHz to 70MHz can be measured using the signal processor. In the accuracy of the period counting part, from 1.81x10**-4% to 1.27% is estimated, and in the accuracy of the validation logic part, from 0.78% to 14.78% is estimated.

  • PDF

Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone (접선유입식과 축상유입식 사이클론의 집진효율 비교)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2011
  • This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

A 0.5-2.0 GHz Dual-Loop SAR-controlled Duty-Cycle Corrector Using a Mixed Search Algorithm

  • Han, Sangwoo;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.2
    • /
    • pp.152-156
    • /
    • 2013
  • This paper presents a fast-lock dual-loop successive approximation register-controlled duty-cycle corrector (SARDCC) circuit using a mixed (binary+sequential) search algorithm. A wider duty-cycle correction range, higher operating frequency, and higher duty-cycle correction accuracy have been achieved by utilizing the dual-loop architecture and the binary search SAR that achieves the fast duty-cycle correcting property. By transforming the binary search SAR into a sequential search counter after the first DCC lock-in, the proposed dual-loop SARDCC keeps the closed-loop characteristic and tracks variations in process, voltage, and temperature (PVT). The measured duty cycle error is less than ${\pm}0.86%$ for a wide input duty-cycle range of 15-85 % over a wide frequency range of 0.5-2.0 GHz. The proposed dual-loop SARDCC is fabricated in a 0.18-${\mu}m$, 1.8-V CMOS process and occupies an active area of $0.075mm^2$.

A Study on the Reaction Time Reduction Method for the ECM System by using the Feed-back Tracking-gate Filtering (귀환 추적게이트 필터링에 의한 ECM 체계 반응시간 단축 방법에 관한 연구)

  • Kim, So-Yeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.77-86
    • /
    • 2006
  • Usually, a tracking-gate of the tracker is used to track the target radar signal in the active ECM system. In this paper, we propose the feed-back tracking-gate filtering method. The designed method applies a tracking-gate of the tacker to the ECM system's receiver as a rejection or pass filter selected by the receiver's purpose, and the specific target signals can be passed or rejected though this tracking-gate filter. Thus, the number of input signals within the receiver's search band is minimized owing to this filter except the target signals. In conclusion, the EW equipment's reaction time can be reduced and the error value about the target signals can be lower than the previous methods'.

Analog-to-Digital Conveter Using Synchronized Clock with Digital Conversion Signal (디지털 변환신호와 동기화된 클록을 사용하는 아날로그-디지털 변환기)

  • Choi, Jin-Ho;Jang, Yun-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.522-523
    • /
    • 2017
  • Analog-to-Digital converter is designed using a current conveyor circuit and a time-to-digital converter. The analog voltage is sampled using the current conveyor circuit and then the voltage is converted to time information by the discharge of the sampling voltage. The time information is converted to digital value by the counter-type time-to-digital converter. In order to reduce the converted error the clock is synchronized with the time information pulse.

  • PDF

Robust technique using magnetohydrodynamics for safety improvement in sodium-cooled fast reactor

  • Lee, Jong Hui;Park, Il Seouk
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.565-578
    • /
    • 2022
  • Among Generation IV reactors, the sodium-cooled fast reactor (SFR) is attracting attention as a system having great potential for commercial use. Gas entrainment is a thermal-hydraulic issue related to the safety problem of the reactor core in the SFR. Typically, a dipped plate or baffles are installed under the free surface to suppress gas entrainment. However, these approaches can cause gas entrainment in other locations and require many trial-and-error and verifications. In this study, a new strategy using magnetohydrodynamics to suppress gas entrainment in the SFR is proposed. In a counter-flow model, a judgment criterion of gas entrainment occurrence was developed for both water and liquid metal. Moreover, the gas entrainment can be completely suppressed by applying a magnetic field.

Proprioception and the Sense of Ownership (고유수용성 감각과 신체 소유감)

  • Sharon Yoon
    • Korean Journal of Cognitive Science
    • /
    • v.34 no.3
    • /
    • pp.243-257
    • /
    • 2023
  • This paper aims to examine how proprioception provides a sense of ownership over one's body and physical actions. Proprioception is a sense that relies on somatic interoceptors rather than exteroceptors that receive external stimuli and has epistemic importance of knowing the presence, location, and movement of bodily parts. In this paper, I will argue that Shoemaker's principle, "Immunity to Error through Misidentification (IEM)" can be applied to proprioception by focusing on one of the intrinsic features of proprioception: First-Person Perspective. I will advocate the following two arguments by defeating each of Marcel's pathological counter-examples in turn. Proprioception is infallible in that it provides a sense of ownership over one's body and physical actions. Second, proprioception is indispensable for the sense of ownership of one's body and physical actions.

Rainfall Prediction of Seoul Area by the State-Vector Model (상태벡터 모형에 의한 서울지역의 강우예측)

  • Chu, Chul
    • Water for future
    • /
    • v.28 no.5
    • /
    • pp.219-233
    • /
    • 1995
  • A non-stationary multivariate model is selected in which the mean and variance of rainfall are not temporally or spatially constant. And the rainfall prediction system is constructed which uses the recursive estimation algorithm, Kalman filter, to estimate system states and parameters of rainfall model simulataneously. The on-line, real-time, multivariate short-term, rainfall prediction for multi-stations and lead-times is carried out through the estimation of non-stationary mean and variance by the storm counter method, the normalized residual covariance and rainfall speed. The results of rainfall prediction system model agree with those generated by non-stationary multivariate model. The longer the lead time is, the larger the root mean square error becomes and the further the model efficiency decreases form 1. Thus, the accuracy of the rainfall prediction decreases as the lead time gets longer. Also it shows that the mean obtained by storm counter method constitutes the most significant part of the rainfall structure.

  • PDF