• Title/Summary/Keyword: Er,Cr: YSGG Laser

Search Result 25, Processing Time 0.022 seconds

EFFECTS ON ER,CR:YSGG LASER ON PERI-IMPLANTITIS (임프란트 주위염에 대한 Er,Cr:YSGG 레이저 조사가 미치는 영향)

  • Choi, Sung-Lim;Kim, Jin-Hwan;Hwang, Dong-Hyeon;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.428-436
    • /
    • 2008
  • For Longevity of implant, considerations of biomechanical and microbiological aspects must be done. Recently, due to the remarkable development of bone grafting procedure. Implant has been implanted into the more favorable sites but peri-implantitis resulted from periodontal bacteria may obscure the long-term prognosis. Although many different modalities have been introduced to treat the failed implant. Implant's surface and irreversible bony destruction around the implant prevents good result. After Er,Cr:YSGG (waterlase) laser using the wave-length of 2780nm has been introduced to dental field, good results have been reported. Because waterlase uses the hydrokinetic force of water. It is excellent device to detoxify the implant surface mechanically without the heat generation and damage to the implant surface. We designed to evaluate waterlase effect on the peri-implantitis has been occurred after implantation. Four beagle dogs were involved. We have made four premolar extraction in each right and left side of the lower jaw and placed two implants in the anterior of the jaw as a control and six implant were placed posterior in each socket after extraction immediately as an experimental group. We tied floss-silk in each implant to make peri-implantitis intentionally. After three months, we explored peri-implant sites on each experimental fixtures. Using waterlase laser irradiation was performed on that implantitis sites under 3W, air 30% and water 20% intensity for 2 minutes. In control group, we repositioned the flap to cover the exposed fixture without any supportive care. Three months later, we sacrificed experimental animals and extracted and preparated bone blocks with Donath and Breuner (982), Donath (988)'s methods and examined under microscope. We have obtained good re-osseointegration around fixtures after treating with waterlaser irradiation. But it was shown fibroosseointegration in the control group.

Effect of Laser Pre-Drilling on Insertion Torque of Orthodontic Miniscrews: A Preliminary Study

  • Kim, Keun-Hwa;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.66-73
    • /
    • 2017
  • Purpose: To evaluate the effect of different-sized drill tips and laser irradiation times on the initial stability of orthodontic miniscrews placed in Er,Cr:YSGG-laser pre-drilled holes in an animal model. Materials and Methods: Laser pre-drilled holes were made in dog mandibular bone with an Er,Cr:YSGG laser using irradiation times of 5, 7, 9, 11, and 13 seconds, and tip diameters of 0.4 and 0.6 mm. The maximum diameter and depth of the pre-drilled holes was measured with micro computed tomography. The maximum insertion torque was measured during placement the miniscrew. Result: Laser pre-drilled holes were conical shaped. The maximum diameter of pre-drilled holes increased with longer laser irradiation times (P>0.05) and larger tip diameters (P<0.05). The depth of pre-drilled holes increased with longer laser irradiation times and larger tip diameters (P<0.05). When the 0.4 mm tip, but not the 0.6 mm tip, was used, the insertion torque decreased significantly with longer laser irradiation times (P<0.05). Conclusion: Tip diameter impacted insertion torque more than irradiation time. It takes at least 9 seconds using a 0.6 mm tip to create a 0.8 mm diameter and 1.0 mm depth hole in thick cortical bone.

Modified laser etching technique of enamel for bracket bonding (브라켓 부착을 위한 변형된 레이저 부식법)

  • Yun, Min-Sung;Lee, Sang-Min;Yang, Byung-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.87-94
    • /
    • 2010
  • Objective: Many studies have carried out research on comparisons between laser etching and conventional etching systems to investigate methods of reinforcing shear bond strength. The purposes of this study were to assess the efficiency of bonding with erbium, chromium doped: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser etching combined with the conventional etching technique. Methods: Sixty-four sound premolars, extracted for orthodontic purposes, were randomly divided into 4 groups and treated in the following manner. First group, conventional etching of 37% phosphoric acid for 15 seconds (control); second group, 1.5 W laser etching for 10 seconds followed by conventional etching; third group, conventional etching followed by 1.5 W laser etching; fourth group, 1.5 W laser etching for 15 seconds only. We assessed the shear bond strength, the surface characteristics, and the adhesive remnant index scores between all groups. Results: Experimental groups showed higher shear bond strength than the control group. But no statistically significant differences were found between the second and third groups. Adhesive remnant scores were compared with the Kruskal-Wallis test, and no statistically significant differences were found between all groups. Conclusions: To obtain maximum shear bonding strength, a combined technique of Er,Cr:YSGG and 37% phosphoric acid is useful even though it may be inconvenient.

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

Influence of access cavity design on calcium hydroxide removal using different cleaning protocols: a confocal laser scanning microscopy study

  • Seda Falakaloglu;Merve Yeniceri Ozata;Betul Gunes;Emmanuel Joao Nogueira Leal Silva;Mustafa Gundogar;Burcu Gucyetmez Topal
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.25.1-25.13
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of endodontic access cavities design on the removal of calcium hydroxide medication of the apical third of mandibular incisor root canal walls and dentinal tubules with different cleaning protocols: EDDY sonic activation, Er,Cr:YSGG laser-activated irrigation, or conventional irrigation with IrriFlex. Materials and Methods: Seventy-eight extracted human mandibular incisors were assigned to 6 experimental groups (n = 13) according to the endodontic access cavity and cleaning protocol for calcium hydroxide removal: traditional access cavity (TradAC)/EDDY; ultraconservative access cavity performed in the incisal edge (UltraAC.Inc)/EDDY; TradAC/Er,Cr:YSGG; UltraAC. Inc/Er,Cr:YSGG; TradAC/IrriFlex; or UltraAC.Inc/IrriFlex. Confocal laser scanning microscopy images were used to measure the non-penetration percentage, maximum residual calcium hydroxide penetration depth, and penetration area at 2 and 4 mm from the apex. Data were statistically analyzed using Shapiro-Wilk and WRS2 package for 2-way comparison of non-normally distributed parameters (depth of penetration, area of penetration, and percentage of non-penetration) according to cavity and cleaning protocol with the significance level set at 5%. Results: The effect of cavity and cleaning protocol interactions on penetration depth, penetration area and non-penetration percentage was not found statistically significant at 2 and 4 mm levels (p > 0.05). Conclusions: The present study demonstrated that TradAC or UltraAC.Inc preparations with different cleaning protocols in extracted mandibular incisors did not influence the remaining calcium hydroxide at 2 and 4 mm from the apex.

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.

Clinical applcation of water laser (Er,Cr:YSGG) (물방울 레이저의 다양한 임상 적용)

  • Park, Jung-Hyun
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.385-390
    • /
    • 2018
  • Laser means "Light amplification by stimulated emission of radiation". Laser have unique characteristics according to wavelength. Wavelenth of Waterlase is 2780nm and it can be absorbed to water and hydroxyapatite. When laser is applied to some material, its temperature goes up due to laser's energy. But in dental treatment high temperature is not good for teeth. High temperature can make dental pulp and bone necrosis. Waterlase can be absorbed to water droplet, so when it burst, it can cut soft and hard tissue without raising temperature. so it is so proper to dental treatment.

  • PDF

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.