The Application of Equivalent Area to the Volume Velocity for Using the Vibro-acoustical Reciprocity (진동-음향 상반 원리에 이용되는 음원의 유효 면적 측정)

  • 고강호
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.943-948
    • /
    • 1999
  • This paper proposes a feasible and effective method for measuring the mechanical-acoustic transfer function by the application of equivalent area and velocity transfer function, a manifestation of the vibro-acoustical reciprocity principle. On the contrary to the volume velocity used in traditional method, the equivalent area is a peculiar raidation characteristics of sound sources and not influenced by any input signal for driving sound source. This invariant property of equivalent area can get rid of boresome works to measure the volume velocity of a sound source every time the driving signal is changed. Moreover, this method has a remarkable advantage to use a general loudspeaker as an accoustic exciter without the assumption of point source and can be applied to all kinds of sound sources even if they are not omni-directional sources.

  • PDF

Contact Stress Evaluations for the Ball Groove of Weiss Type Constant velocity joint (Weiss형 등속조인트 볼 홈의 접촉응력평가)

  • 김완두;이순복
    • Tribology and Lubricants
    • /
    • v.5 no.2
    • /
    • pp.60-67
    • /
    • 1989
  • For the life prediction and fatigue failure prevention of the constant velocity joint, the maximum equivalent stress and its location in depth from the contact area are essential. These values give the fundamental information to determine the depth of the surface hardening treatment at the contact area. Contact stresses are evaluated at the surface and subsurface of the ball groove of the Weiss type constant velocity joint. The maximum contact pressure and the maximum equivalent stress are obtained. The effects of various parameters such as the radius of ball groove, friction coefficient, and residual stress are studied. The maximum equivalent stress and the maximum contact pressure increase as the radius of the ball grove increases. The location of the maximum equivalent stress moves toward surface as the friction coefficient increases. It was also found that the maximum equivalent stress becomes minimum when the compressire residual stress is about 0.16 times of the maximum contact pressure.

Correlation of elastic input energy equivalent velocity spectral values

  • Cheng, Yin;Lucchini, Andrea;Mollaioli, Fabrizio
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.957-976
    • /
    • 2015
  • Recently, two energy-based response parameters, i.e., the absolute and the relative elastic input energy equivalent velocity, have been receiving a lot of research attention. Several studies, in fact, have demonstrated the potential of these intensity measures in the prediction of the seismic structural response. Although some ground motion prediction equations have been developed for these parameters, they only provide marginal distributions without information about the joint occurrence of the spectral values at different periods. In order to build new prediction models for the two equivalent velocities, a large set of ground motion records is used to calculate the correlation coefficients between the response spectral values corresponding to different periods and components of the ground motion. Then, functional forms adopted in models from the literature are calibrated to fit the obtained data. A new functional form is proposed to improve the predictions of the considered models from the literature. The components of the ground motion considered in this study are the two horizontal ones only. Potential uses of the proposed equations in addition to the prediction of the correlation coefficients of the equivalent velocity spectral values are shown, such as the prediction of derived intensity measures and the development of conditional mean spectra.

A Study on Minimising the Errors on the Boundary Conditions when Using an Equivalent Source Technique for a Modelling of Sound Field inside an Enclosure (등가소스법을 이용한 공간 내의 음장 모델링에서 경계면 조건 오차의 최소화에 관한 연구)

  • Baek, Kwang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.581-586
    • /
    • 2000
  • The equivalent source method is used to calculate the internal pressure field for an enclosure which can have arbitrary boundary conditions and may include internal objects which scatter the sound. Some of the equivalent positions are chosen to be the same as the first order images of the source inside the enclosure, some are positioned on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. The convergence of this method is checked by evaluating the velocity error at a larger number of monitoring positions. Example results are presented for various numbers of sources and evaluation points. The results showed that in general the more equivalent sources increased the accuracy of the sound field predictions but the accuracy is not too much sensitive to the numbers of evaluation points.

  • PDF

Optimization of the Number and Position of Far Field Sources in Using the Equivalent Source Method (등가음원법에서의 원거리음원의 위치와 개수의 최적화 연구)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.743-750
    • /
    • 2003
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and nay include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. Typical ESM modeling uses two groups of equivalent source positions. One group includes the first order images of the source inside the enclosure. The Positions of the other group are usually on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal far field sources positions when using the equivalent source method. In general, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study. optimal far field source locations are searched using simulated annealing method for various radii of spheres where far field sources are located. Simulation results showed that optimally located sources with adequate distance away from the enclosure center gave better result than sources with even distribution even with a smaller number of far field sources.

A study on the Optimal Far field Source locations in the Acoustic Modelling using Equivalent Source Method (등가소스법을 이용한 실내 음장 모델링에서의 원방 소스 최적화 연구)

  • Baek, Kwang-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.216-221
    • /
    • 2001
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and may include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. In the ESM modelling, some of the equivalent positions are chosen to be the same as the first order images of the source inside the enclosure, some are positioned on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal equivalent source positions, the far field sources. Typically, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study, optimal far field source locations are searched using simulated annealing method and simulation results showed that optimally located sources gave better accuracy even with a smaller number of far field sources.

  • PDF

Studying the Park-Ang damage index of reinforced concrete structures based on equivalent sinusoidal waves

  • Mazloom, Moosa;Pourhaji, Pardis;Shahveisi, Masoud;Jafari, Seyed Hassan
    • Structural Engineering and Mechanics
    • /
    • v.72 no.1
    • /
    • pp.83-97
    • /
    • 2019
  • In this research, the vulnerability of some reinforced concrete frames with different stories are studied based on the Park-Ang Damage Index. The damages of the frames are investigated under various earthquakes with nonlinear dynamic analysis in IDARC software. By examining the most important characteristics of earthquake parameters, the damage index and vulnerability of these frames are investigated in this software. The intensity of Erias, velocity spectral intensity (VSI) and peak ground velocity (PGV) had the highest correlation, and root mean square of displacement ($D_{rms}$) had the lowest correlation coefficient among the parameters. Then, the particle swarm optimization (PSO) algorithm was used, and the sinusoidal waves were equivalent to the used earthquakes according to the most influential parameters above. The damage index equivalent to these waves is estimated using nonlinear dynamics analysis. The comparison between the damages caused by earthquakes and equivalent sinusoidal waves is done too. The generations of sinusoidal waves equivalent to different earthquakes are generalized in some reinforced concrete frames. The equivalent sinusoidal wave method was exact enough because the greatest difference between the results of the main and artificial accelerator damage index was about 5 percent. Also sinusoidal waves were more consistent with the damage indices of the structures compared to the earthquake parameters.

The Effect of the Wind Direction and Velocity on the Salt Contamination of the Distribution Facilities (풍향 및 풍속이 배전설비의 염분오손에 미치는 영향)

  • Kim, Chan-Young;Kim, Dong-Myung;Kwon, Tae-Ho;Chun, Sung-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.499-500
    • /
    • 2006
  • The salt contamination on the distribution facilities was investigated with the wind direction and velocity. Most previous researches were concentrated on the measurement of The Equivalent Salt Deposit Density(ESDD) without environmental consideration. The wind direction and velocity of the many environmental conditions are the most important factors to analyze salt contamination. Pohang area which is located on the south and east of the Korean Peninsula was chosen to do this research. This research will present the result of ESDD depending on the wind direction and velocity.

  • PDF

지표 물리탐사법을 이용한 염/담수 영역의 고분해능 영상화

  • 박권규;신제현;박윤성;황세호
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.446-449
    • /
    • 2004
  • High resolution geophysical imaging to delineate costal aquifer and seawater- freshwater interface has been applied in Baesu-eup, Yeonggwang-gun, Jeolla province Electrical resistivity information from vertical electrical sounding and 2-D electrical resistivity survey is key parameter to map equivalent Nacl concentration map over the survey area. Seismic velocity from refraction tomographic survey, on the other hand, gives more reliable information on the subsurface stratagraphy than electrical resistivity methods which frequently suffer from low resolution due to masking effect. We imaged high-resolution 3-D structure of costal aquifer by correlating the electrical resistivity with seismic velocity, and mapped equivalent NaCl concentration map using resistivity and hydro-geological information from well logging.

  • PDF

A Comparison of the Trainees' Evacuation Characteristics according to the Indoor Smoke-fullfill during the Safety Training on Ship (선상안전교육 시 선내 연기충진 여부에 따른 실습생의 피난이동특성 비교)

  • Hwang, Kwang-Il;Cho, Ik-Soon;Yun, Gwi-Ho;Kim, Byeol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.422-429
    • /
    • 2018
  • To make students recognize the danger of fire smoke that may occur in ships and to improve the response capability, spaces for safety educ ation were built inside the training ship, and scenarios were developed. This study is an analysis of the movement characteristics of the students acquire d under each scenario. Followings are the summary of the analysis results. In the non-smoke environments, there was no difference in the velocity of escape movement between the case of without block on the familiar route and the case of with unexpected block. However, when the indoor was filled with smoke, the visibility became very low because of the smoke density and the average velocity was 62.5 % slower than the case where it was not. Regardless of the scenarios, the average equivalent velocity on the complex path was faster than the simple straight path, and the standard deviation was smaller. Under the smoke-fullfilled environment, although the relative velocity probability distributions of the complex passage and the entire passag e are very similar, the inter-individual fluctuation of the relative velocity ratio of the complex passage to that of the entire passage was very large. On the other hand, equivalent velocity could be expressed by the logarithmic function of the visibility. Also, as the tension of the students increased, the equivalent velocities were accelerated on all scenarios.