• Title/Summary/Keyword: Equivalent scattering size

검색결과 11건 처리시간 0.023초

어류 부레의 형태학적 차이에 따른 음향산란강도의 자세 및 주파수 의존성의 변화 (Changes in the Orientation and Frequency Dependence of Target Strength due to Morphological Differences in the Fish Swim Bladder)

  • 이대재
    • 한국수산과학회지
    • /
    • 제48권2호
    • /
    • pp.233-243
    • /
    • 2015
  • Controlled broadband acoustic scattering laboratory experiments were conducted using a linear chirp signal (95-220 kHz), and x-ray images of live and model fish with an artificial swim bladder were analyzed to investigate the changes in orientation and frequency dependence of target strength (TS) due to morphological differences in fish swim bladders. The broadband echoes from live and model fish were measured over an orientation angle range of ${\pm}45^{\circ}$ in the dorsal plane and in approximately $1^{\circ}$ increments. The location of nulls in the simulated echo response of the SINC [sinc function] model was overlaid on the TS map, showing the orientation and frequency dependence of fish TS, and they matched very well. It was possible to infer the equivalent fish scattering size (or swim bladder) using the null spacing in the experimentally obtained broadband TS map. Good agreement was observed for inferring the equivalent scattering size between the SINC model and the broadband echoes measured for the three fish species (black scraper Thamnaconus modestus; goldeye rockfish Sebastes thompsoni; and whitesaddled reef fish Chromis notatus). Some results of this inference are discussed.

Advantage of the Intensive Light Scattering by Plasmonic Nanoparticles in Velocimetry

  • Rong, Tengda;Li, Quanshui
    • Current Optics and Photonics
    • /
    • 제6권1호
    • /
    • pp.79-85
    • /
    • 2022
  • Tracers are one of the critical factors for improving the performance of velocimetry. Silver and gold nanoparticles as tracers with localized surface-plasmon resonance are analyzed for their scattering properties. The scattering cross sections, angular distribution of the scattering, and equivalent scattering cross sections from 53° and 1.5° half-angle cones at 532 nm are calculated, with particle sizes in the nanoscale range. The 53° and 1.5° half-angle cones used as examples correspond respectively to the collection cones for microscope objectives in microscopic measurements and camera lenses in macroscopic measurements. We find that there is a transitional size near 35 nm when comparing the equivalent scattering cross sections between silver and gold nanoparticles in water at 532 nm. The equivalent scattering cross section of silver nanoparticles is greater or smaller than that of gold nanoparticles when the particle radius is greater or smaller than 35 nm respectively. When the radius of the plasmonic nanoparticles is smaller than about 44 nm, their equivalent scattering cross sections are at least ten times that of TiO2 nanoparticles. Plasmonic nanoparticles are promising for velocimetry applications.

비이온성 미셀용액과 수중유형 마이크로에멀젼계의 특성 및 수단 IV의 가용화 (Characteristics of Non-ionic Micellar and O/W Microemulsion Systems and Solubilization of Sudan IV)

  • 지웅길;황성주;장은옥;현종목
    • 약학회지
    • /
    • 제39권5호
    • /
    • pp.495-505
    • /
    • 1995
  • The O/W microemulsion systems were made from 2 or 4% (w/w) oil (soybean oil, olive oil or isopropyl myristate) and 10, 15 or 20% (w/w) Brij 96. They were compared with micellar solution of equivalent surfactant concentration m therms of physicochemical properties, and the solubilization of sudan IV. They were characterized by dynamic light scattering, stability, surface tension, viscosity and rheogram. The mean diameters of O/W microemulsion systems were 10-15nm, and those of Brij 96 micellar solutions were 18-19 nm. Both of them were monodisperse systems. The O/W microemulsion systems showed Newtonian flow and their apparent viscosities were lower than those of micellar solutions. The surface tensions of O/W microemulsion systems were increased or decreased depending on the types of oil used, when compared with those of micellar solutions. The O/W microemulsion systems were very stable, and did not show any flocculation or aggregation. Their mean diameters were not changed after three months. But oxidation was observed in microemulsions without nitrogen gas at high temperature. There was a significant improvement in the sudan IV solubffimtion in micromulsion compared with that m the micellar solution containing equivalent concentration of surfactant. The size distribution and mean diameters of O/W micromulsions were not changed when sudan IV was solubilized.

  • PDF

화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어 (Control of Size and Morphology of Particles Using CO2 Laser in a Flame)

  • 이동근;이선재;최만수
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

$BaTiO_3$의 입도와 분체특성과의 상관 관계 연구 (Characterization of relationship between particle size and powder properties for $BaTiO_3$)

  • 전명표;조정호;김병익
    • 한국결정성장학회지
    • /
    • 제15권6호
    • /
    • pp.244-251
    • /
    • 2005
  • 수열합성법에 의해 제조된 티탄산바륨 (BT01, BT02, BT03, BT04, BT05)의 입자크기와 분체특성과의 상관관계를 비표면적, 제타전위, XPS, XRD 및 SEM에 의해 조사하였다. 레이져광산법에 의해 측정된 입자의 크기는 비표면적과 XRD를 통해 결정된 격자이방성과 밀접한 관계가 있음을 보였다. 분말의 비표면적은 입자의 크기가 증가함에 따라 감소하였으며, BT03 시료는 동일한 입자크기의 BT04에 비하여 큰 비표면적을 보였으며, 이는 입자들의 응집에 기인하는 것으로 SEM사진 및 XRD 분석을 통하여 밝혀졌다. 입자의 크기가 증가함에 따라 제타전위는 증가하는 경향을 보였으며, BT02와 BT03 분말은 다른 분말에 비하여 제타전위가 큰 음의 값을 나타내었다. XPS 분석결과 분쇄시 티탄산바륨과 물 사이의 반응에 의한 $Ba^{2+}$ 이온의 용출과 관련이 있는 것으로 분석되었다.

플루비프로펜 및 플루비프로펜 악세틸이 함유된 마이크로에멀젼의 제조 및 평가 (Preparation and Evaluation of Flurbiprofen- and Flurbiprofen Axetil-loaded Microemulsion)

  • 신광현;황성주;박경미;김종국
    • 약학회지
    • /
    • 제41권5호
    • /
    • pp.607-614
    • /
    • 1997
  • Flurbiprofen- and flurbiprofen axetil-loaded microemulsions composed of soybean oil, poloxamer 407, glycerine and water were prepared by generator-type homgenizer and ultrasoni c probe system. The particle size of microemulsions was measured by the dynamic light scattering method. The pharmacokinetics and organ distribution of flurbiprofen were investigated after intravenous injection of flurbiprofen solution, flurbiprofen-loaded microemulsion and flurbiprofen axetil-loaded microemulsions equivalent to 10mg/kg of flurbiprofen to rats. Blood samples were collected from the anterior ciliary artery of rats for 24hr, and flurbiprofen in plasma and organs was analyzed by HPLC. Stable microemulsions were prepared. Even though there is a little change in droplet size just after the preparation, no creaming and no separation were occured during the storage period for 6 months at 4, 21, 37 and 45$^{\circ}C$. Pharmacokinetic parameters and organ distribution of flurbiprofen after intravenous injection of flurbiprofen- and flurbiprofen axetil-loaded microemulsions emulsified with poloxamer 407 were not significantly different from those of commercial lipid microemulsion emulsified with lecithin. Therefore, it is concluded that flurbiprofen- and flurbiprofen axetil-loaded microemulsion prepared with poloxamer 407 could be used as a parenteral formulation.

  • PDF

Physicochemical Properties of Corn Starch-derived Branched Dextrin Produced by a Branching Enzyme

  • Song, Eun-Bum;Min, Byoung-Cheol;Hwang, Eun-Sun;Lee, Hyong-Joo
    • Food Science and Biotechnology
    • /
    • 제17권2호
    • /
    • pp.234-240
    • /
    • 2008
  • The optimal conditions for the production of branched dextrin from com starch (CSBD) using branching enzyme (BE) were established by investigating the degree of retrogradation of the gelatinized starch. The physicochemical properties of CSBD prepared using the established process were evaluated. It was found that physicochemical properties of com starch were greatly modified by BE treatment. CSBD had a higher dextrose-equivalent value and water solubility than the corresponding control. On the other hand, the viscosities in gelatinized solution and amylose contents of CSBD were lower than those of the control. A high-performance size-exclusion chromatography/multiangle laser light scattering/retractive index (HPSEC/MALLS/RI) system showed that the average molecular weight of CSBD was lower than that of the control. The pasting viscosities of CSBD were stable during the entire temperature cycle. In general, the BE treatment resulted in the retrogradation during storage being lower for CSBD than for the control.

철도객차용 크로스 빔의 경량화 설계에 관한 연구 (A Study on the Lightweight Design of a Cross Beam for Railway Passenger Coach)

  • 장득열;전형용
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.126-133
    • /
    • 2017
  • This report investigates the stress distribution according to the location and shape change of the circular hole for the lightweight design of the cross beam of a railway passenger car and studies the lightweight design. To design a lightweight cross beam with a circular hole, we selected the non-circular crossbeam as a basic model, examined the stress distribution and displacement by position and determined the location, shape, size and quantity of the hole for light weight. We analyzed the effects of the position and shape of the hole on the maximum equivalent stress and displacement. The influencing factors were set as the design parameters, and the stress value was examined according to the variation of each variable. By considering the stress value according to the change of each variable and selecting the design parameter with the narrowest scattering value of the stress at each position of the hollow cross beam with various hole positions and shapes, we studied a cross beam with a circle hole under identical load condition to have an equal stress distribution to that of a non-circular cross beam.

비균질 팬텀에서 소조사면에 대한 필름측정, 회선/중첩 모델과 몬테 카를로 모사의 비교 연구 (Comparison of Film Measurements, Convolution$^{}$erposition Model and Monte Carlo Simulations for Small fields in Heterogeneous Phantoms)

  • 김상노;제이슨손;서태석
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.89-95
    • /
    • 2004
  • 세기조절방사선치료(IMRT)에서는 일반적인 방사선 치료에서 사용되는 조사면에 비해 비교적 작은 크기의 빔조각(beamlet)을 사용하여 방사선의 세기를 조절하는 새로운 치료법으로 이에 대한 비균질 효과는 많은 연구가 필요하다. 우리는 기하학적으로 일정한 비균질 팬텀들에서 몬테카를로 시뮬레이션에 의한 선량값을 라디오크로믹 필름에 의한 선량값과 회선/중첩 방법에 의한 선량 계산 값과 서로 비교하였다. 몬테 카를로 모사를 위하여 EGS4 코드 기반의 BEAM 코드를 사용하였으며 이를 이용하여 Varian 2300C/D 선형가속기의 두부를 호사하였다. 측정과 모사에 사용된 조사면은 1${\times}$1$\textrm{cm}^2$, 2${\times}$2$\textrm{cm}^2$, 그리고 5${\times}$5$\textrm{cm}^2$이었다. 또한 팬텀의 물질은 솔리드 워터, 폐 등가 물질, 뼈 등가 물질을 사용하여 세 경우의 비극질 팬텀들을 설정하여 방사선을 조사하였다. 회선/중첩 방법과 몬테 카를로 방법에 의한 선량 계산치는 광자 측면선량의 경우 $\pm$1 mm, 깊이선량의 경우 $\pm$2% 이내로 선량측정치와 잘 일치함을 볼 수 있었다. 결론적으로 회선/중첩 방법과 몬테 카를로 방법이 소조사면에서도 필름 측정 데이터와 잘 일치함을 확인할 수 있었다.

Performance Analysis of Low-level Radiation Shielding Sheet with Diamagnetic Nanoparticles

  • Cho, Jae-Hwan;Kim, Myung-Sam
    • Journal of Magnetics
    • /
    • 제20권2호
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, the authors attempted to produce a medical radiation shielding fiber that can be produced at a nanosize scale and that is, unlike lead, harmless to the human body. The performance of the proposed medical radiation shielding fiber was then evaluated. First, diamagnetic bismuth oxide, an element which, among elements that have a high atomic number and density, is harmless to the human body, was selected as the shielding material. Next, 10-100 nm sized nanoparticles in powder form were prepared by ball milling the bismuth oxide ($Bi_2O_3$), the average particle size of which is $1-500{\mu}m$, for approximately 10 minutes. The manufactured bismuth oxide was formed into a colloidal solution, and the radiation shielding fabric was fabricated by curing after coating the solution on one side or both sides of the fabric. The thicknesses of the shielding sheets prepared with bismuth oxide were 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, and 1.0 mm. An experimental method was used to measure the absorbed dose and irradiation dose by using the lead equivalent test method of X-ray protection goods presented by Korean Industrial Standards; the resultant shielding rate was then calculated. From the results of this study, the X-ray shielding effect of the shielding sheet with 0.1 mm thickness was about 55.37% against 50 keV X-ray, and the X-ray shielding effect in the case of 1.0 mm thickness showed shielding characteristics of about 99.36% against 50 keV X-ray. In conclusion, it is considered that nanosized-bismuth radiation shielding fiber developed in this research will contribute to reducing the effects of primary X-ray and secondary X-ray such as when using a scattering beam at a low level exposure.