• Title/Summary/Keyword: Equivalent ratio

Search Result 1,266, Processing Time 0.028 seconds

Analysis of multi leaf spring based on contact mechanics - a novel approach

  • Kumaravelan, R.;Ramesh, S.;Gandhi, V.C. Sathish;Agu, M. Joemax;Thanmanaselvi, M.
    • Structural Engineering and Mechanics
    • /
    • v.47 no.3
    • /
    • pp.443-454
    • /
    • 2013
  • A leaf spring, especially the longitudinal type is liable and persistent element in automotive suspension system. In the present scenario the composite materials are widely used in the automobile industries has shown a great interest in the replacement of steel spring due to high strength by weight ratio. Previous investigations focused on stresses and displacement analysis of single leaf spring for different materials. The present work aims to design and analysis of leaf spring for two different cases by considering the Young's modulus to yield strength ratio. In the first case the analysis deals with the design and analysis of a single cantilever solid triangle beam which is an equivalent beam of a spring with three leaves having uniform strength. In the second case a 3-beams of rectangular cross section has been considered which is equivalent to a spring with three leaves. The analysis was carried out based on contact mechanics approach. The results were compared, that the fiberglass composite leaf spring is suitable for high loading capacity, reliability and efficiency.

The efficiency and robustness of a uni-directional tuned liquid damper and modelling with an equivalent TMD

  • Tait, M.J.;Isyumov, N.;El Damatty, A.A.
    • Wind and Structures
    • /
    • v.7 no.4
    • /
    • pp.235-250
    • /
    • 2004
  • The current study reports the results of an experimental program conducted on a structure fitted with a liquid damper (TLD) and subjected to harmonic excitation. Screens were placed inside the TLD to achieve the required inherent damping. In the first part of the study, reduced scale models of the building-TLD systems were tested under two levels of excitation. The efficiency of the damper was assessed by evaluating the effective damping provided to the structure and comparing it to the optimum effective damping value, provided by a linear tuned mass damper (TMD). An extensive parametric study was then conducted for one of the three models by varying both the excitation amplitude and the tuning ratio, defined as the ratio of the TLD sloshing frequency to the natural frequency of the structure. The effectiveness and robustness of a TLD with screens were assessed. Results indicate that the TLD can be tuned to achieve a robust performance and that its efficiency is not significantly affected by the level of excitation. Finally, the equivalent amplitude dependent TMD model, developed in the companion paper is validated using the system test results.

Studies on T-Shaped composite columns consist of multi separate concrete-filled square tubular steel sections under eccentric axial load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Feng, Changxi;Liu, Rui
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.217-234
    • /
    • 2016
  • In order to investigate mechanical properties and load-bearing capacity of T-shaped Concrete-Filled Square Steel Tubular (TCFST) composite columns under eccentric axial load, three T-shaped composite columns were tested under eccentric compression. Experimental results show that failure mode of the columns under eccentric compression was bending buckling of the whole specimen, and mono column performs flexural buckling. Specimens behaved good ductility and load-bearing capacity. Nonlinear finite element analysis was also employed in this investigation. The failure mode, the load-displacement curve and the ultimate bearing capacity of the finite element analysis are in good agreement with the experimental ones. Based on eccentric compression test and parametric finite element analysis, the calculation formula for the equivalent slenderness ratio was proposed and the bearing capacity of TCFST composite columns under eccentric compression was calculated. Results of theoretical calculation, parametric finite element analysis and eccentric compression experiment accord well with each other, which indicates that the theoretical calculation method of the bearing capacity is advisable.

Effects of Magnetite added with Metallic Oxide on the Decomposition Reaction of Carbon Dioxide (CO$_2$ 분해 반응에서 금속 산화물이 첨가된 $Fe_2O_4$의 영향)

  • Kim, Seung-Ho;Park, Young-Goo
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.32-37
    • /
    • 1998
  • The Carbon Dioxide is the gas, which causes green house effects, unusual changes in the weather, destruction of the life. Almost every nation in the world is trying to search the countermeasure to this poisonous gas. I synthesized $Fe_3O_4$ and NaOH, in order to decompose the Carbon Dioxide. Among the particles synthesizing $Fe_3O_4$, I chose the equivalent ratio 1.00 which can decompose the Carbon Dioxide best, and fixed that equivalent ratio and added the 0.005-3.00 mole percentage of NiCl$_2$ and synthesized $Fe_3O_4$. I studied the decomposition of the Carbon Dioxide and methanized reaction, by measuring its crystal structure, thermochemistrical character and specific surface area. In decomposing the Carbon Dioxide, I used oxygen-deficit Magnetite which I produced by injecting the hydrogen gas into the synthesized sample. I observed the methanization reaction by raising the temperature of sample up to 650$\circ$C and having it reacted with the hydrogen gas. The decomposition of the Carbon Dioxide was added 0.005, 0.03, 0.05 mole percentage of NiCl$_2$ was more effective than pure $Fe_3O_4$. All sample in which the decomposition of the Carbon Dioxide took place produced the methane gas.

  • PDF

Formation and Chemical Characteristics of Dewfall in 2005 at Busan (2005년 부산지역 이슬의 생성과 화학적 특성)

  • Jeon, Byung-Il;Hwang, Yong-Sik;Park, Gwang-Soon
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.847-853
    • /
    • 2006
  • In order to understand chemical characteristics and formation of dewfall in Busan, we analysed monthly distribution of dewfall, and investigated its chemical composition of dewfall. This study used the modified teflon plate $(1m{\times}1m)$ at Jangyongsil science high school from June 2005 to October 2005. In order to estimate qualitatively water soluble components, IC, ICP and UV methods for water soluble ions are also used respectively. Dewfall amount of sampling periods (26 day) collected 1.29 mm. Distribution of water soluble ions in dewfall founded the highest concentration $(81.3{\mu}eq/{\ell}\;for\;NO_3^-,\;146.6{\mu}eq/{\ell}\;for\;SO_4^{2-},\;and\;114.3{\mu}eq/{\ell}\;for\;nss-SO_4^{2-})$ during the June. pH was the lowest by 5.12 June, and October (pH 6.68) by most high and average pH was 5.46. Monthly equivalent ratio of $[SO_4^{2-}]/[NO_3^-]$ showed the highest value (2.94) during the September, the lowest value (1.77) during the July, and the mean value was 3.45.

Influences of Exposures on Dry Matter Yields and Nutrient Contents of Grasses II. Comparative studies of south and north exposure on nutrient contents of temperate grasses (경사방향이 목초의 수량 및 양분함량에 미치는 영향 II. 주요 목초에 대한남북향사면의 양분함량비교)

  • 박근제;이필상;신재순;정연규
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.7 no.2
    • /
    • pp.97-102
    • /
    • 1987
  • To find out the nutrient contents of temperate grasses on the south and north slope, a field experiment was conducted with five forage species of Dactylis glomerata, Festuca arundinacea, Phleum pratense, Agrostis gigantea and Trifolium repens. It was treated by randomized block design with 4 replications and lasted from September, 1983 to October, 1986 in Suweon. The results obtained are summarized as follows: 1. Mean chemical compositions except NFE and crude fiber of the forage species on the south slope were a little more contented than that of north. But all crude components were significant difference among the species on the south and north exposure. 2. Production of TDN (total digestible nutrient), StE (starch equivalent) ME (metabolizable energy) and NEL (net energy lactation) of different grass species on the north slope were much more increased by 5-30% per ha (Dactylis glomerata by 5-876, Festuca arundinacea by 5%, Phleum pratense by 24-26% and Agrostis gigantea by 25-30%) than that of same grasses on the south, however, those of Trifolium repens were much more increased by 4 1-42% per ha in the south. 3. Mineral contents, Ca/P ratio and K/ (Ca + Mg) equivalent ratio of the species were slightly different between the exposures. But considering the factors of occuring grass tetany, those of the forage species on the north slope were better than that of same species on the south.

  • PDF

LEFM Analysis of Patch Repaired Steel Plates by p-Version Layer Model (p-Version 적층모델을 통한 팻취 보강된 강판의 선형탄성파괴역학 해석)

  • Han, Sang-Hyun;Shin, Young-Shik;Woo, Kwang-Sung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.487-492
    • /
    • 2007
  • The enhancement of the service life of damaged or cracked structures is a major issue for researchers and engineers. The hierarchical void element with the integrals of Legend polynomials is used to characterize the fracture behavior of unpatched crack as well as repaired crack with bonded composite patches by computing the stress intensity factors and stress contours at the crack tip. The numerical approach is based on the v-version degenerate shell element including the theory of anisotropic laminated composites. Since the equivalent single layer approach is adopted in this study, the proposed element is necessary to represent a discontinuous crack part as a continuum body with zero stiffness of materials. Thus the aspect ratio of this element to represent the crack should be extremely slender. The sensitivity of numerical solution with respect to energy release rate, displacement and stress has been tested to show the robustness of hierarchical void element as the aspect ratio is increased up to 2000. The stiffness derivative method and displacement extrapolation method have been applied to calculate the stress intensity factors of Mode I problem.

  • PDF

An Adaptive Connection Admission Control Method Based on the Measurement in ATM Networks (ATM망에서 측정 기반 적응적 연결 수락 제어)

  • 윤지영;김순자
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.8
    • /
    • pp.1907-1914
    • /
    • 1998
  • This paper proposes the adaptive connection admission cotrol using the variale MRR(measurement reflection ratio) and the distribution of the number of cells arriving during the fixed interval. This distribution is estimated from the measured number of cells arriving at the output buffer during the fixed interval and traffic parameters specified by user. MRR is varied by the difference of estimated distribution and measurement distribution. As MRR is adaptively varied by estimated distribution error of accepted connections, it quickly reduces estimation error. Also, the scheduling scheme is proposed for multiplexed traffic with various traffic characteristics. For each traffic class, this scheme estimates adaptively equivalent bandwidth and schedules according to equivalent bandwidth ratio of each traffic class, so it improves cell loss rate and link utilization.

  • PDF

Permanent Magnet Overhang Effect on the Characteristics in Brushless DC Motor (브러시리스 직류전동기 특성에 대한 영구자석 오버행 효과)

  • 전연도;약미진치;이주
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.229-236
    • /
    • 2004
  • In this paper, the effect of permanent magnet overhang structure on the characteristics in Brushless DC motor has analyzed quantitatively. We classified the overhang structure as symmetric and asymmetric. 3D equivalent magnetic circuit network (EMCN) method which uses the permeance as the distributive variable is used for the efficient analysis of magnetic field. The overhang effect which increases the linkage flux at the stator is verified by comparison between overhang and no overhang structure. In addition, it is known that no load back electro motive force (EMF) is also increased due to the overhang effect. In case of asymmetric overhang structure, the ratio effect of the upper to lower overhang length on the magnetic forces is analyzed. Form the analysis results, the variation of the asymmetric overhang ratio has a significant effect on the axial magnetic force except the radial and tangential magnetic forces. The validity of the analysis results is also clarified by comparison between calculated results and measured ones such as back EMF and cogging torque.

Compound damping cable system for vibration control of high-rise structures

  • Yu, Jianda;Feng, Zhouquan;Zhang, Xiangqi;Sun, Hongxin;Peng, Jian
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.641-652
    • /
    • 2022
  • High-rise structures prone to large vibrations under the action of strong winds, resulting in fatigue damage of the structural components and the foundation. A novel compound damping cable system (CDCS) is proposed to suppress the excessive vibrations. CDCS uses tailored double cable system with increased tensile stiffness as the connecting device, and makes use of the relative motion between the high-rise structure and the ground to drive the damper to move back-and-forth, dissipating the vibration mechanical energy of the high-rise structure so as to decaying the excessive vibration. Firstly, a third-order differential equation for the free vibration of high-rise structure with CDCS is established, and its closed form solution is obtained by the root formulas of cubic equation (Shengjin's formulas). Secondly, the analytical solution is validated by a laboratory model experiment. Thirdly, parametric analysis is conducted to investigate how the parameters affect the vibration control performance. Finally, the dynamic responses of the high-rise structure with CDCS under harmonic and stochastic excitations are calculated and its vibration mitigation performance is further evaluated. The results show that the CDCS can provide a large equivalent additional damping ratio for the vibrating structures, thus suppressing the excessive vibration effectively. It is anticipated that the CDCS can be used as a good alternative energy dissipation system for vibration control of high-rise structures.