• Title/Summary/Keyword: Equivalent R-C circuit

Search Result 68, Processing Time 0.024 seconds

A Study on the Performance of Automatic Thermostatic Valves for Hot Water Heating System in Residential Buildings (공동주택 난방용 자동온도조절기의 성능해석 연구)

  • Ahn, Byung-Cheon;Lee, Tae-Won;Kim, Yong-Ki;Song, Jae-Yeob
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.457-462
    • /
    • 2005
  • In this study, the performance of automatic thermostatic valves according to each heating method of a large scale residential building were researched by simulation. The flow characteristics of the entire pipe networks of the hot water radiant heating system is analized by using linear analysis method. For the analysis of unsteady heat transfer phenomena in each household, the method of using electric equivalent R-C circuit is applied.

  • PDF

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

A Distance Relaying Algorithm Based on the Integral Approximation of a Differential Equation (적분근사를 이용한 거리 계전 알고리즘)

  • Jung, B.T.;Seo, J.C.;Cho, K.R.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.180-182
    • /
    • 1993
  • A distance protection algorithm for detecting faults at power transmission lines is presented in this paper. The algorithm is based on the differential equation related to the voltage and the current at an equivalent circuit of a transmission line which is composed of the lumped resistance and inductance. The presented integration method has high performance at though the fault voltage and the current are heavily distorted with the DC offset and harmonics which occurred at transient states after faults.

  • PDF

The Analysis on Vector Control Characteristics of IM Using Finite Element Method (FEM을 이용한 유도 전동기의 벡터제어 특성 해석 연구)

  • Im, D.H.;Kwon, B.I.;Lee, J.H.;Woo, K.I.;Kim, C.E.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.56-58
    • /
    • 1995
  • Dynamic characteristics of the vector controlled induction motor has been analysed using d-q equivalent circuit. However, for the design of the induction motor, the analysis of an accurate response characteristic are needed. In this paper, dynamic characteristic analysis method using 2-D Finite Element Method (FEM), which takes the motion equation of the rotor into account and considers the physical motion of the rotor by an automatic subdivision of mesh, are explained.

  • PDF

Modeling of pentacene MIS capacitors with admittance measurements and the effects of dispersive charge transport

  • Jung, Keum-Dong;Lee, Cheon-An;Park, Dong-Wook;Park, Byung-Gook;Shin, Hyung-Cheol;Lee, Jong-Duk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.67-69
    • /
    • 2006
  • Capacitance and loss values of pentacene MIS capacitors with different thicknesses are measured as a function of frequency for the modeling of the devices. The equivalent circuit for the ideal MIS capacitor is adopted to model the obtained admittance, so the values of $C_i,\;C_d,\;C_b$, and $R_b$ are determined for each pentacene thickness. In the loss curve, broader loss peaks are observed in measurement than the modeling results regardless of the pentacene thickness. By considering the effects of dispersive charge transport in bulk semiconductor, more accurate modeling results are obtained.

  • PDF

0.6 mAh All-Solid-State Thin Fim Battery Fabricated on Alumina Substrate (알루미나 기판상에 구현된 0.6mAh급 전고상 박막전지)

  • Park, H.Y.;Nam, S.C.;Lim, Y.C.;Choi, K.G.;Lee, K.C.;Park, G.B.;Cho, S.B.
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.181-185
    • /
    • 2005
  • Lithium cobalt oxide thin film cathode, having thickness of $2.9{\mu}m$ with area of $4cm^2$, was deposited on platinum patterned alumina substrate by radio frequency magnetron sputtering. Li/Co molar ratio, which is an important factor for battery performance, was measured as a function of argon working pressure and applied R.F. power. Constant current charge and discharge performances were characterized with high rate discharge and cycling behavior. Using AC impedance analysis, internal resistance of the thin film battery was measured and simulated by proposed equivalent circuit model.

Monitoring of Corrosion Rates of Carbon Steel in Mortar under a Wet-Dry Cyclic Condition

  • Kim, Je-Kyoung;Kang, Tae-Young;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.179-183
    • /
    • 2007
  • The corrosion behavior of metal covered with mortar under a wet-dry cyclic condition were investigated to apply for the measurement of corrosion rates of reinforcing steel in concrete structure. The carbon steel in mortar having t=3 mm cover thickness was exposed to the alternate condition of 6 h immersion in chloride containing solution and 18 h drying at $25^{\circ}C$ and 50%RH. The electrochemical phenomena of a carbon steel and mortar interface was explained by an equivalent circuit consisting of a solution resistance, a charge transfer resistance and a CPE(Constant Phase Element). The corrosion rates were monitored continuously during exposure using an AC impedance technique. Simultaneously, the current distribution over the working electrode during impedance measurement was analyzed from the phase shift, $\theta$, in an intermediate frequency. The result showed that corrosion rate monitoring using an AC impedance method is suitable under the given exposure conditions even during the drying period when the metal is covered with the wetted mortar.

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

Impedance spectroscopy analysis of organic light emitting diodes with the $CF_4$ anode plasma treatment ($CF_4$ 플라즈마 처리된 ITO박막을 이용한 유기 EL 소자의 성능향상에 관한 임피던스 분석)

  • Park, Hyung-June;Kim, Hyun-Min;Lee, Jun-Sin;Sohn, Sun-Young;Jung, Dong-Geun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.320-321
    • /
    • 2006
  • In this work, impedance Spectroscopic analysis was applied to study the effect of plasma treatment on the surface of indium-tin oxide (ITO) anodes using $CF_4g$ as and to model the equivalent circuit for organic light emitting diodes (OLEDs) with the $CF_4$ plasma treatment of ITO surface at the anodes. This device with ITO/TPD/$Alq_3$/LiF/Al structure can be modeled as a simple combination of a resistor and a capacitor. The $CF_4$ plasma treatment on the surface of ITO shifts the vacuum level of the ITO as a result of which the barrier height for hole injection at the ITO/organic interface is reduced. The Impedance spectroscopy measurement of the devices with the $CF_4$ plasma treatment on the surface of ITO anodes shows change of values in parallel resistance ($R_p$) and parallel capacitance ($C_p$).

  • PDF

Parameter and Brightness Characteristic of Antena according to Coil turns on Electrodeless Fluorescent Lamp (무전극 램프 안테나의 권선수에 따른 휘도와 파라미터 특성)

  • Yang, Jong-Kyung;Choi, Gi-Seung;Pack, Gwang-Hyeon;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.281-284
    • /
    • 2004
  • In Recent, it became necessary to envelope the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electrodeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter So it is of the utmost importance to design antena and inverter. Therefore, this paper used a transformer principle for efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, used an impedance analyzer in order to confirm a performance enhancement of lamp along design of antenna, and confirmed parameter characteristic of R, L, C, Z, Phase, Q-factor along a change of magnetic flux density. Also, this paper confirmed a luminance characteristic of electrodeless lamp along parameter change with measuring optical characteristic along a change of magnetic flux density.

  • PDF