• Title/Summary/Keyword: Equivalent Load

Search Result 1,188, Processing Time 0.024 seconds

Calculation of the Earthquake Vulnerability of the Bridge Foundation Considering the Characteristics of the Ground (지반의 특성을 고려한 교량기초의 지진취약도 산정)

  • Lee, Donggun;Song, Kiil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.2
    • /
    • pp.13-23
    • /
    • 2022
  • The ground-structure interaction of the bridge foundation has been pointed out as a major factor influencing the behavior of the bridge during earthquakes. In this study, the effect of characteristics of ground and bridge foundation on the earthquake vulnerability is investigated. From the pseudo-static analysis, it is confirmed that non-linearity becomes lesser and horizontal load becomes greater when surcharge is considered. It is also found that as the ground worsens and the size of foundation decreases, horizontal load reduces. To derive reasonable structural model for bridge foundation, fragility curve is obtained considering four conditions (fixed condition, equivalent linear condition, non-linear without surchage condition, non-linear with surcharge condition) and compared. Seismic analysis is performed on single pier with Opensees. From the earthquake vulnerability analysis, it is found that shallow foundation can be assumed as fixed condition. In conservative approach, stiffness of spring can be obtained based on Korean highway bridge design code for pile foundation which can consider the ground condition.

Evaluation of Deformation Capacity of Various Steel Springs Subjected to Tensile Loading or Uniaxial Cyclic Loading (인장하중 및 반복하중을 받는 강재 스프링의 변형 성능 평가)

  • Kwon, Hee-Yong;Hwang, Seung-Hyeon;Yang, Keun-Hyeok;Kim, Sanghee;Choi, Yong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, to evaluate the possibility of using a steel spring as a displacement-dependent damping device, tensile loading and cyclic loading tests were performed. The main experimental variables were the type of steel (SAE9254 and SS275), the spring constant (700 N/mm, 1,000 N/mm, and 1,400 N/mm), and the presence or absence of heat treatment for SAE9254. As a result of the tensile test, the ratios of the measured spring constant to the design spring constant of the steel springs made with SAE9254 ranged from 1.08 to 1.13, while the ratios of the design spring constant and the measured spring constant of the steel springs made with SS275 ranged from 0.86 to 0.97. After yielding, the slope values of the load-displacement curve of the SAE9254 with/without heat treatment were about 240~251 N/mm and 92 N/mm, respectively, but the slope values of the load-displacement response of SS275 were almost zero. According to the uniaxial cyclic loading test results, all specimens were satisfied with three conditions for a displacement-dependent damping device in KDS 41 17 00 (2019): the maximum force and minimum force at zero displacement, the maximum force and minimum force at the maximum displacement, and the energy dissipation capacity. In addition, the equivalent damping ratios of steel springs made with SAE9254(non-heat treatment) and SS275 were approximately 2.8 times and 1.9 times greater, respectively, than that of steel springs made with SAE9254.

Experimental and analytical study of squat walls with alternative detailing

  • Leonardo M. Massone;Cristhofer N. Letelier;Cristobal F. Soto;Felipe A. Yanez;Fabian R. Rojas
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.497-507
    • /
    • 2024
  • In squat reinforced concrete walls, the displacement capacity for lateral deformation is low and the ability to resist the axial load can quickly be lost, generating collapse. This work consists of testing two squat reinforced concrete walls. One of the specimens is built with conventional detailing of reinforced concrete walls, while the second specimen is built applying an alternative design, including stirrups along the diagonal of the wall to improve its ductility. This solution differs from the detailing of beams or coupling elements that suggest building elements equivalent to columns located diagonally in the element. The dimensions of both specimens correspond to a wall with a low aspect ratio (1:1), where the height and length of the specimen are 1.4 m, with a thickness of 120 mm. The alternative wall included stirrups placed diagonally covering approximately 25% of the diagonal strut of the wall with alternative detailing. The walls were tested under a constant axial load of 0.1f'cAg and a cyclic lateral displacement was applied in the upper part of the wall. The results indicate that the lateral strength is almost identical between both specimens. On the other hand, the lateral displacement capacity increased by 25% with the alternative detailing, but it was also able to maintain the 3 complete hysteretic cycles up to a drift of 2.5%, reaching longitudinal reinforcement fracture, while the base specimen only reached the first cycle of 2% with rapid degradation due to failure of the diagonal compression strut. The alternative design also allows 46% more energy dissipation than the conventional design. A model was used to capture the global response, correctly representing the observed behavior. A parametric study with the model, varying the reinforcement amount and aspect ratio, was performed, indicating that the effectiveness of the alternative detailing can double de drift capacity for the case with a low aspect ratio (1.1) and a large longitudinal steel amount (1% in the web, 5% in the boundary), which decreases with lower amounts of longitudinal reinforcement and with the increment of aspect ratio, indicating that the alternative detailing approach is reasonable for walls with an aspect ratio up to 2, especially if the amount of longitudinal reinforcement is high.

Lateral Drift Control of High-rise Buildings using Partial Reanalysis Algorithm (부분재해석 기법을 이용한 고층건물 횡변위제어)

  • Lee, Jae-Cheol;Kim, Chee-Kyeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.81-88
    • /
    • 2009
  • This paper alined at the development of a lateral drift control method that is able to quantitatively control the lateral drift of global node. For this, we applied an efficient partial reanalysis algorithm. By using this algorithm, we could recalculate the displacement and member force of the specific node without reanalyzing the entire structure when member stiffness changes partially. The theoretical concepts of the algorithm are so simple that it is not necessary to solve the complicate differential equation or to repeat the analysis of entire structure. The proposed method calculates the drift contribution of each member for the global displacement according to the variation of section sizes by using the algorithm. Then by changing the member sizes as the order of drift contribution, we could control the lateral drift of global node with a minimum quantity of materials. 20 story braced frame structure system is presented to illustrate the usefulness of proposed method. It is shown that the proposed method is very effective in lateral drift control and the results obtained by proposed method are consistent with those of commercial analysis program.

A Study on the Characteristics of SM570TMC Plates in Compression Members (SM570TMC 강재의 압축재 특성에 관한 연구)

  • Im, Sung Woo;Kim, Yo Suk;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.357-363
    • /
    • 2005
  • There is a great need for high-strength steel especially for the high-rise steel building structure. High-strength steels, however, may have mechanical properties that are significantly different from those of the conventional steels. The application of high-strength steels to building structures should be reviewed as to whether the inelastic behavior equivalent to that of conventional steels can be attained or not. In this study, SM570TMC steel was tested to evaluate buckling strength under axial compressive force. The comparison tests for local buckling strength evaluation of box-type and H-shaped welded columns were performed with variable width-thickness ratios. As for the experimental check, the maximum strength of stub column was determined by local buckling as far as the limit of width-to-thickness ratio was satisfied with current design codes. Also, the strength of the stub column did not decrease suddenly by local buckling before maximum strength even when the ratio is not satisfied. The buckling strength of SM570TMC steel was higher than both ASD (Allowable Stress Design) and LRFD (Load and Resistance Factor Design) specifications.

Design & Fabrication of an InGaP/GaAs HBT MMIC Power Amplifier for IMT-2000 Handsets (IMT-2000 단말기용 InGaP/GaAs HBT MMIC 전력증폭기 설계 및 제작)

  • 채규성;김성일;이경호;김창우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11A
    • /
    • pp.902-911
    • /
    • 2003
  • Using InGaP/GaAs HBT power cells with a 2.0${\times}$20$\mu\textrm{m}$$^2$ emitter area of a unit HBT, a two stage MMIC power amplifier has been developed for IMT-2000 handsets. An active-bias circuit has been used for temperature compensation and reduction in the idling current. Fitting on measured S-parameters of the HBT cells, circuit elements of HBT's nonlinear equivalent model have been extracted. The matching circuits have been designed basically with the extracted model. A two stage HBT MMIC power amplifier fabricated using ETRI's HBT process. The power amplifier produces an 1-㏈ compressed output power(P$\_$l-㏈/) of 28.4 ㏈m with 31% power added efficiency(PAE) and 23-㏈ power gain at 1.95 GHz in on-wafer measurement. Also, the power amplifier produces a 26 ㏈m output power, 28% PAE and a 22.3-㏈ power gain with a -40 ㏈c ACPR at a 3.84 ㎒ off-center frequency in COB measurement.quency in COB measurement.

The Effect of Dilution on Porticle Deposition in The Entry Deposit of The Ferrogroms (Ferrography에서 샘풀희석률이 마모입자 정량분석에 미치는 영향)

  • 권오관
    • Tribology and Lubricants
    • /
    • v.1 no.1
    • /
    • pp.38-45
    • /
    • 1985
  • Ferrograms prepared from off samples collected during testing in the transition region were originally diluted at 20:1. To obtain some information about the effect of dilution on the analysis procedures, a series of measurements were made on ferrograms prepared to different dilutions in the range 6 to 30:1 from oil samples collected after testing in the four ball machine at the 51 kg and 55 kg load, respectively, Fig. 1. The variations in area covered, perimeter, intercept and particle count were then plotted as a function of dilution level and appropriate mathematical expressions established such that the results obtained at any dilution level specified within the range can then be corrected back to an equivalent undiluted value. The effect of dilution on the variance of the particle size distribution was also investigated. The main results are tabulated, Tables 1-5 and also plotted as a function of dilution, level Figs. 2-9.

Micro-mechanical Failure Prediction and Verification for Fiber Reinforced Composite Materials by Multi-scale Modeling Method (멀티스케일 모델링 기법을 이용한 섬유강화 복합재료의 미시역학적 파손예측 및 검증)

  • Kim, Myung-Jun;Park, Sung-Ho;Park, Jung-Sun;Lee, Woo-Il;Kim, Min-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.17-24
    • /
    • 2013
  • In this paper, a micro-mechanical failure prediction program is developed based on SIFT (Strain Invariant Failure Theory) by using the multi-scale modeling method for fiber-reinforced composite materials. And the failure analysis are performed for open-hole composite laminate specimen in order to verify the developed program. First of all, the critical strain invariants are obtained through the tensile tests for three types of specimens. Also, the matrices of strain amplification factors are determined through the finite element analysis for micro-mechanical model, RVE (Representative Volume Element). Finally, the microscopic failure analysis is performed for the open-hole composite laminate specimen model by applying a failure load obtained from tensile test, and the predicted failure indices are evaluated for verification of the developed program.

Nonlinear Analysis of Reinforced Concrete Shells(II) (철근(鐵筋)콘크리트 쉘구조(構造)의 비선형(非線型) 해석(解析)(II))

  • Kim, Woon Hak;Shin, Hyun Mock;Shin, Hyun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.79-87
    • /
    • 1991
  • An efficient numerical procedure for material and geometric nonlinear analysis of reinforced concrete shells under monotonically increasing loads through their elastic, inelastic and ultimate load ranges is developed by using the finite element method. The 8-node Serendipity isoparametric element developed by the degeneration approach including the transverse shear deformation is used. A layered approach is used to represent the steel reinforcement and to discretize the concrete behavior through the thickness. The total Lagrangian formulation based upon the simplified Von Karman strain expressions is used to take into account the geometric nonlinearity of the structure. The material nonlinearities are taken into account by comprising the tension, compression, and shear models of cracked concrete and a model for reinforcement in the concrete; and also a so-called smeared crack model is incorporated. The steel reinforcement is assumed to be in a uniaxial stress state and is modelled as a smeared layer of equivalent thickness. This method will be verified a useful tool to account for geometric and material nonlinearities in detailed analysis of reinforced concrete concrete shells of general form through numerical examples of the sequential paper( ).

  • PDF

A High-Voltage Compliant Neural Stimulation IC for Implant Devices Using Standard CMOS Process (체내 이식 기기용 표준 CMOS 고전압 신경 자극 집적 회로)

  • Abdi, Alfian;Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.58-65
    • /
    • 2015
  • This paper presents the design of an implantable stimulation IC intended for neural prosthetic devices using $0.18-{\mu}m$ standard CMOS technology. The proposed single-channel biphasic current stimulator prototype is designed to deliver up to 1 mA of current to the tissue-equivalent $10-k{\Omega}$ load using 12.8-V supply voltage. To utilize only low-voltage standard CMOS transistors in the design, transistor stacking with dynamic gate biasing technique is used for reliable operation at high-voltage. In addition, active charge balancing circuit is used to maintain zero net charge at the stimulation site over the complete stimulation cycle. The area of the total stimulator IC consisting of DAC, current stimulation output driver, level-shifters, digital logic, and active charge balancer is $0.13mm^2$ and is suitable to be applied for multi-channel neural prosthetic devices.