• Title/Summary/Keyword: Equivalent Dose

Search Result 535, Processing Time 0.027 seconds

Antioxidant, Alcohol Metabolizing Enzyme, and Hepatoprotective Activities of Dendropanax morbifera Water Extract (황칠나무 물 추출물의 항산화, 알코올 대사 효소 및 간 보호 활성)

  • Jung, Kyung Im;Jung, Han Nah;Choi, Young Ju
    • Journal of Life Science
    • /
    • v.32 no.5
    • /
    • pp.348-354
    • /
    • 2022
  • The leaves, stems, seeds, and roots of Dendropanax morbifera have been used since ancient times as folk medicines for the treatment of headaches, skin diseases, infectious diseases, and other ailments. This study investigated the antioxidant, alcohol metabolism, and hepatoprotective effects of D. morbifera leaf and stem water extracts. The total polyphenol content of the D. morbifera leaf and stem water extracts was 49.56 mg tannic acid equivalent (TAE)/g, and the 1,1-diphenyl-2-picrylhydrazy (DPPH) radical scavenging activity of the D. morbifera leaf and stem water extracts was 84.09% at 1,000 ㎍/ml concentration. The effects of D. morbifera leaf and stem water extracts on alcohol metabolism were determined by measuring the generation of reduced nicotinamide adenine dinucleotide (NADH) by alcohol dehydrogenase (ADH) and acetaldehyde dehydrogenase (ALDH). The ADH and ALDH activities of D. morbifera leaf and stem water extracts were increased in a dose-dependent manner at 37.68% and 41.67%, respectively, at a 1,000 ㎍/ml concentration. The D. morbifera leaf and stem water extracts showed significant protective effects against tacrine-induced cytotoxicity in HepG2 cells at 50 ㎍/ml. Based on our results, we concluded that D. morbifera leaf and stem water extracts may be used as major pharmacological agents, such as antioxidants, alcohol metabolism, and anti-hepatitis remedies.

Non-clinical Trials using 14C-Acetaminophen to Validate Biomedical Accelerator Mass Spectrometry System (14C-아세트아미노펜 비임상시험을 통한 생체시료 분석용 가속질량분석기의 검증)

  • Jinho Song;Jae Hoon Shim;Jung Bae Park;Chang Su Yeo;Soo Hyeon Bae;Min Sun Choi;Mi Hye Kwon;Kyeong Min Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2023
  • Pharmacokinetic (PK) data provide pivotal information in drug development, and they are usually first studied in the preclinical stage using various animals. However, quite often, animal PK data may not match with human PK, especially in metabolites. Thus, most regulatory agencies in the world make it mandatory to obtain metabolite information using 14C radiolabeled drug in human for small molecule drug candidates. However, such studies are expensive and time consuming and they are usually done at the end of Phase II trials using ~3.7 MBq of 14C labeled drug in a limited number of human subjects. Introduction of accelerator mass spectrometry (AMS) in this kind of study has revolutionized it. Since AMS can measure 14C level as close as natural abundance, it can quantify the amounts of 14C labeled drugs and their metabolites produced in human body that consumes less than the amount of 0.0037 MBq of 14C labeled drug, a very safe level of radioactive dose in human. Therefore, it is now possible to conduct human 14C studies safely in early clinical trials without spending hefty amount of money and time. Korea Radioisotope Center for Pharmaceuticals(KRICP) at Korea Institute of Biological and Medical Sciences(KIRAMS) has established an AMS facility in 2018, housing a 0.5MV AMS manufactured at the US National Electrostatics Corps (NEC). The AMS instrument has been validated using various standard samples that have been prepared at Lawrence Livermore National Laboratory in the US, a worldly reputable provider of AMS standards. In this paper, we present a mass balance study for acetaminophen in rats using AMS and prove that the study results are equivalent with those of literature, which shows the AMS facilities at KRICP has successfully installed and be ready to be used in the various PK studies using 14C labelled compounds for new drug development.

Assessment of natural radioactivity in soil and olive mill pomace utilizing nal (TI) gamma-ray spectrometry and low background alpha/beta counting system

  • Amani Kraishan;Mohammad Abu Shayeb;Hafedh Belmabrouk;Ahmad Ali Husein Qwasmeh;Muzahir Ali Baloch
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1925-1931
    • /
    • 2024
  • The study conducted in the northwest region of Jordan aimed to assess the levels of natural radioactivity in soil and olive mill pomace (OMP) samples. The researchers used Nal (TI) gamma-ray spectrometry to measure the activity concentrations of 226Ra, 232Th, 40K, and 137Cs in the samples. The average activity concentrations of 226Ra, 232Th, 40K, and 137Cs in the soil samples were found to be 18.624 ± 5.82, 12.276 ± 5.728, 518.33 ± 212.57, and 0.140 ± 0.09 (Bq, kg-1), respectively. In the OMP samples, the average activity concentrations of 226Ra, 232Th, and 40K were 7.272 ± 4.386, 3.454 ± 1.503, and 169.997 ± 81.873 (Bq kg-1), respectively, and no 137Cs was detected. The study also investigated fundamental parameters associated with radon, specifically the radon emanation coefficient (RnEC) and radon mass exhalation rate (Ex). The RnEC values ranged from 0.621 to 0.78 (Bq kg-1), with an average value of 0.71 ± 0.06 (Bq kg-1). The estimated Ex from the soil samples ranged from 65.83 to 124.86 (mBq kg-1h-1), with an average value of 99.74 ± 21.73 (mBq kg-1h-1). Regarding radiological hazards, the study examined various parameters, including radium equivalent activity, external and internal hazard indices, gamma and alpha indices, absorbed gamma dose rate, and excess lifetime cancer risk. All of these assessed values were found to be below the worldwide recommended limits for radiological safety. Additionally, the study analyzed the concentrations of gross alpha and gross beta radioactivities in soil and OMP samples. The soil samples had an average gross alpha activity of 4.642 ± 1.04 (Bq kg-1) and an average gross beta activity of 48.13 ± 14.50 (Bq kg-1). The OMP samples showed an average gross alpha activity of 0.32 ± 0.27 (Bq kg-1) and an average gross beta activity of 59.19 ± 12.94 (Bq kg-1). Overall, the obtained results are crucial for evaluating the radiological risks associated with natural radioactivity in the northwest region of Jordan. The findings establish baseline data for comparison and reference for radioactivity levels in the environment.

Development of finasteride polymer microspheres for systemic application in androgenic alopecia

  • Ju Hee Kim;Jungtae Na;Dong-Ho Bak;Byung Chul Lee;Esther Lee;Mi Ji Choi Choong;Ho Ryu;Sangno Lee;Seog-Kyun Mun;Byung Cheol Park;Beom Joon Kim;Hyun-Shik Lee
    • International Journal of Molecular Medicine
    • /
    • v.43 no.6
    • /
    • pp.2409-2419
    • /
    • 2019
  • The use of finasteride for alleviating hair loss has been investigated, and it has been applied as an oral dose medication. However, due to the inconvenience of daily drug administration over long period of time, novel controllable finasteride delivery has been actively investigated. As a novel method of finasteride delivery, the development of finasteride-loaded microspheres for subcutaneous administration is becoming increasingly pharmaceutically important. Therefore, the present study aimed to use finasteride-loaded microspheres in a controlled manner in an attempt to overcome the limitations of the oral administration of finasteride and to cause fewer adverse effects. Finasteride-loaded microspheres containing poly(lactic-co-glycolic acid) and finasteride at a ratio of 4:1 were prepared, and a testosterone-induced androgenic alopecia mouse model was used. Following observation for 10 weeks, the percentage hair growth was 86.7% (total hair growth 60%, partial hair growth 26.7%) in the orally-applied finasteride-treated group as a positive control, and 93.3% (total hair growth 60%, partial hair growth 33.3%) in the finasteride-loaded microspheres-treated group. Serum dihydrotestosterone levels began to decrease at week 6 in the orally-applied finasteride- and finasteride-loaded microsphere-treated groups. In addition, the finasteride-loaded microspheres-treated group exhibited similar follicular number, follicular length, anagen/telogen ratio and hair bulb diameter values to those of the orally-applied finasteride-treated group. Furthermore, the finasteride-loaded microspheres increased the activities of phosphoinositide 3-kinase/protein kinase B and Wnt/β-catenin in relation to hair follicle cell growth signaling in mouse skin, and suppressed the apoptosis of hair follicle cells by reducing the expression of transforming growth factor-β2 and caspase-3, which are indicators of apoptosis. In conclusion, the administration of a single injection of finasteride-loaded microspheres was effective in treating testosterone-induced alopecia. Furthermore, it led to equivalent hair growth effects when compared with orally-applied finasteride, thus revealing the possibility of effective treatment via different routes of administration.

Antioxidant Activities of Dianthus chinensis L. Extract and Its Inhibitory Activities against Nitric Oxide Production and Cancer Cell Growth and Adhesion (패랭이꽃 추출물의 항산화, Nitric Oxide 생성저해, 암세포 성장 및 부착 억제 활성)

  • Lee, Jungjae;Seo, Younggeo;Lee, Junho;Ju, Jihyeung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.1
    • /
    • pp.44-51
    • /
    • 2016
  • The aim of the study was to investigate the antioxidant content and activities of ethanol extract of the edible flower Dianthus chinensis L. (DCE) as well as its inhibitory activities against nitric oxide (NO) production in macrophages and growth and adhesion of human cancer cells. The total polyphenol, flavonoid, and carotenoid levels of DCE were 19.0 mg gallic acid equivalent/g, 65.7 mg quercetin equivalent/g, and $95.0{\mu}g/g$, respectively. The 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity and ferric reducing antioxidant power of DCE at a concentration of $1,000{\mu}g/mL$ were 44% and 51%, respectively. In lipopolysaccharide-treated RAW 264.7 macrophages, treatment with DCE at concentrations of 500 and $1,000{\mu}g/mL$ resulted in significantly reduced NO levels (to 7~23% of the control). In H1299 human lung carcinoma cells and HCT116 human colorectal carcinoma cells, treatment with DCE at concentrations of 250, 500, and $1,000{\mu}g/mL$ resulted in dose-dependent growth inhibition. DCE was also effective in inhibiting adhesion of both H1299 cells (to 55% of the control at concentration of $1,000{\mu}g/mL$) and HCT116 (to 26~40% of the control at concentrations of 250, 500, and $1,000{\mu}g/mL$). These results suggest that DCE exerts antioxidant, anti-inflammatory, and anti-cancer activities in vitro.

Physiological Activity and Physicochemical Properties of Condensed Prunus mume Juice Prepared with Pectinase (Pectinase처리를 한 매실 농축액의 이화학적 특성 및 생리활성)

  • Kim, Jeong-Ho;Cho, Hyun-Dong;Won, Yeong-Seon;Park, Wool-Lim;Lee, Kwan-Woo;Kim, Hyuk-Joo;Seo, Kwon-Il
    • Journal of Life Science
    • /
    • v.28 no.11
    • /
    • pp.1369-1378
    • /
    • 2018
  • Prunus mume Siebold & Zucc., a member of the Rosaceae family (called Maesil in Korea), has been widely distributed in East Asia, e.g. Korea, Japan and China, and its fruit has been used as a traditional drug and health food. In this study, we evaluated physicochemical properties and physiological activities of condensed Prunus mume juice treated with pectinase (PJ). The values of total acidity, pH, sugar contents, turbidity moisture content of the PJ were 35.81%, 2.73, $54.36^{\circ}Brix$, 2.75 and 51.32%, respectively. The PJ had effective DPPH radical scavenging activity, reducing power effect, $H_2O_2$ scavenging activity and ${\beta}$-carotene bleaching effect. DPPH radical scavenging activities of PJ was 46.31%; their reducing power ($OD_{700}$) was 1.80; $H_2O_2$ scavenging activity of PJ was 91.62%; and ${\beta}$-carotene bleaching effect of PJ was 73.02%. Also, PJ showed effective levels of ${\alpha}$-glucosidase inhibition activity. The cell viability was measured by SRB assay. The PJ significantly decreased the cell viability of mouse melanoma cells (B16) and human melanoma cells (SK-MEL-2 and SK-MEL-28) in a dose-dependent manner, however, there was no effect on human keratinocyte HaCaT. In morphological study, PJ-treated SK-MEL-2 cells showed distorted and shrunken cell masses. Total polyphenol contents and total flavonoid contents of PJ were 588.31 mg% (gallic acid equivalent) and 860.45 mg% (rutin equivalent). The antiproliferative effect of PJ seems to be associated with the antioxidant activity of its flavonoid and polyphenol contents. In conclusion, PJ may be beneficial in development of a functional food material.

Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology (방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구)

  • Jang, Young-Ill;Song, Jong-Nam;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.303-308
    • /
    • 2011
  • Background/Aims : The increasing use of diagnostic and therapeutic interventional radiology calls for greater consideration of radiation exposure risk to radiologist and radiological technician, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a protective grass shield. Methods : A protective grass was following data depth, 0.8 cm; width, 100 cm; length, 100 cm, lead equivalent, 1.6 mmPb. The protective shield was located between the patient and the radiologist. Thirty patients (13 male and 17 female) undergoing interventional radiology between September 2010 and December 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective grass shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source. Results : The mean patient age was 69 years. The mean patient height and weight was $159.7{\pm}6.7$ cm and $60.3{\pm}5.9$ kg, respectively. The mean body mass index (BMI) was $20.5{\pm}3.0$ kg/m2. radiologists received $1530.2{\pm}550.0$ mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to $50.3{\pm}85.2$ mR/hr with the protective lead shield (p-value<0.0001). The radiation exposure to radiologist and radiological technician was significantly reduced by the use of a protective lead shield (p value <0.0001). The amount of radiation exposure during interventional radiology was related to the patient' BMI (r=0.749, p=0.001). Conclusions : This protective shield grass is effective in protecting radiologist and radiological technician from radiation exposure.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.