• Title/Summary/Keyword: Equivalent 2D Model

Search Result 203, Processing Time 0.028 seconds

Speed Sensorless Vector Control of Induction Motor Using MATLAB/SIMULINK and dSPACE DS1104 (MATLAB/SIMULINK와 dSPACE DS1104를 이용한 유도 전동기의 속도 센서리스 벡터제어)

  • Lee, Dong-Min;Lee, Yong-Suk;Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.212-218
    • /
    • 2007
  • This paper presents a implementation of speed sensorless vector control of induction motor using MATLAB/SIMULINK and dSPACE DS1104. Proposed flux estimation algorithm, which utilize the combination of the voltage model based on stator equivalent model and the current model based on rotor equivalent model, enables stable estimation of rotor flux. Proposed rotor speed estimation algorithm utilizes the estimated flux. And the estimated rotor speed is used to speed control of induction motor. Overall system consists of speed controller, current controller, and flux controller using the most general PI controller. Speed sensorless vector control algorithm is implemented as block diagrams using MATLAB/SIMULINK. And realtime control is performed by dSPACE DS1104 control board and Real-Time-Interface(RTI).

  • PDF

Effective Equivalent Finite Element Model for Impact Limiter of Nuclear Spent Fuel Shipping Cask made of Sandwich Composites Panels (사용후 핵연료 수송용기 샌드위치 복합재 충격완충체의 유효등가 유한요소 모델 제시)

  • Kang, Seung-Gu;Im, Jae-Moon;Shin, Kwang-Bok;Choi, Woo-Suk
    • Composites Research
    • /
    • v.28 no.2
    • /
    • pp.58-64
    • /
    • 2015
  • The purpose of this paper is to suggest the effective equivalent finite element model for the impact limiter of a nuclear spent fuel shipping cask made of sandwich composite panels. The sandwich composite panels were composed of a metallic facesheet and a core material made of urethane foam, balsa wood and red wood, respectively. The effective equivalent finite element model for the impact limiter was proposed by comparing the results of low-velocity impact test of sandwich panels. An explicit finite element analysis based on LS-DYNA 3D was done in this study. The results showed that the solid elements were recommended to model the facesheet and core of sandwich panels for impact limiter compared to combination modeling method, in which the layered shell element for facesheet and solid element for core material are used. In particular, the solid element for balsa and red wood core materials should be modeled by the element elimination approach.

Analysis of refraction status on the Presbyopia in Korea (한국인 노안 굴절상태 분석)

  • Kim, Douk-Hoon;Lee, Min-Ho
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.2
    • /
    • pp.1337-1344
    • /
    • 2019
  • Purpose. This study was the analyze the refractive status of presbyopia in Korea. Methods. The subjects was from November 2018 to October 2019, two hundred thirty four subjects( 117 male subjects, 117 female subjects; from 40-year old to 88-year old ) were performed in refraction test using the Auto-Refraction(Speed -K model, Japan). The myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)≤-0.50 diopters, SE ≥+1.00 D, cylinder error ≥0.75 D and SE difference≥1.00 D between binocular eyes, respectively. Results. The refractive status by spherical equivalent among all subjects was myopia 61.43%, astigmatism 86.86%, emmetropia 19.18%, anisometropia 12.07%, and hyperopia 18.54. The prevalence of myopia and astigmatism were much more common in male. However, The hyperopia and astigmatism were much more common in female. The prevalence of spherical equivalent was much common from -0.50 diopter to -5.00 diopter. On the other hand, the prevalence of astigmatism and myopia was much more than hyperopia in all subjects. There was a statistical significance between OD and OS of the female and male in the spherical equivalent power(p<.000). However, there was not statical significant between female and male of OD and OS in the spherical equivalent power(p<.070). On the other hand, The prevalence of againest axis in astigmatism was more common in all subjects. In ADD power for the near vision correction, the female was much more diopter than male. Conclusions. These results suggested that the analysis of the refractive status on the presbyopia in Korea can give the useful diagnosis data for the correction of visual acuity at near distance.

Analysis of Optical Pickup Actuator by 3-D EMCN method (3-D EMCN법을 이용한 광 픽업 액츄에이터의 해석)

  • Kim, Gin-A;Chung, Tea-Kyung;Choi, In-Ho;Hong, Sam-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.771-773
    • /
    • 2001
  • In this paper, three dimensional Equivalent Magnetic Circuit Method(3-D EMCN method) a numerical analysis method which supplements to magnetic equivalent circuit adding numerical technique, is proposed for analysis Optical Pickup Actuator. (3) This method provides better characteristics both in precision of the analysis and in computation time than other analysis method such as three-dimensional Finite Element Method. We choose the simple 2-magnet moving coil type pickup actuator model and verify upper yoke effect using this method.

  • PDF

2-dimensional analytical method of RC column considering nonlinearity of strain distribution in out-of-plane direction (면외 변형률 분포의 비선형성을 고려한 RC 기둥의 2차원 해석에 관한 연구)

  • 김익현;이종석;정혁창
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.621-624
    • /
    • 2003
  • The columns with large widths in out-of-plane direction fail showing the high nonlinearity of strain distribution. In order to predict the nonlinear behavior with reasonable accuracy in 2 dimensional analysis the material models taking this characteristic into account are indispensible. In this study equivalent softening model is developed which releases the same amount of energy at failure as that of 3-D analysis. Its validity is confirmed by comparing the analysis result with that of 3-D.

  • PDF

Structural analysis of a thick composite rotor hub system by using equivalent properties (등가 물성을 이용한 두꺼운 복합재 로터 허브 시스템의 구조 해석)

  • ;Yanti Rachmadini
    • Composites Research
    • /
    • v.16 no.5
    • /
    • pp.7-14
    • /
    • 2003
  • Modeling of thick composite structures for finite element analysis is relatively complicated. 2-D plane elements may cause inaccurate result since the plane stress condition cannot be applicable in these structures. Therefore a 3-D modeling should be used. However, the difficulty to model all the layers with different material properties and ply orientation arise in this case. In this paper, an equivalent modeling is proposed and numerically tested for analysis of thick composite structures. By grouping layers with same material and ply orientation, number of elements through the thickness is remarkably reduced and still the result is close enough to the one from a detail finite element model. MSC/NASTRAN and PATRAN are used for the analysis. The proposed modeling technique has been applied for analysis of composite rotor hub system designed by Korea Aerospace Research Institute(KARI). Using the proposed equivalent modeling technique, we could conduct stress analysis for the hub system and check the safety factor of each part.

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

Design of Tapped Coupled-Line Filters Using a New Equivalent Circuit Model of Tapped lines (탭 선로의 등가회로를 이용한 여파기 설계)

  • Han, Sung-Jin;Kim, Kang-Wook
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.371-375
    • /
    • 2003
  • In this paper, a new design method for coupled-line filters with tapped input/output has been developed. The design equations for this tapped filter have been obtained using a new equivalent circuit model of tapped lines. From an edge coupled-line filter, tapped lines replaces the input/output coupled lines which tend to have very narrow gaps (few mils). Therefore, tapped coupled-line filters tend to be less sensitive to filter fabrication tolerances and to be easily fabricated using milling tools. The new filter design algorithm allows very accurate filter design for frequencies less than 20 GHz and bandwidth less than 20%. Above 20 GHz, the filter performance can be optimized starting from the filter design algorithm in this paper. Simulation problems with 2-D EM tools to characterize filter performance at high frequencies have shown to be solved by providing a channel for the filter to eliminate higher order modes.

  • PDF

Analysis of Parameters Influence on the Characteristics of Thomson Coil Type Actuator of Arc Eliminator Using Adaptive Segmentation Equivalent Circuit Method

  • Li, Wei;Jeong, Young-Woo;Yoon, Hee-Sung;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.282-289
    • /
    • 2010
  • A Thomson coil type actuator is applied as the driving unit in an arc eliminator system. To eliminate the arc efficiently, the speed of the actuator is required as fast as possible with certain limit of the exciting current. Therefore, the dynamic characteristics of the Thomson coil type actuator should be analyzed in an effective way. In this paper, a novel solving technique has been developed based on the equivalent circuit model which is set up by dividing the conducting plate into multi segments. To guarantee the calculation accuracy and improve the calculation efficiency, an adaptive refinement algorithm is suggested based on the field continues condition. The proposed method has been verified by the FEM calculation and experiment. The influence of circuit and plate parameters to the performance of the actuator is also investigated, from which a reasonable set of parameters can be found.

A Rigorous 2D Approximation Technique for 3D Waveguide Structures for BPM Calculations

  • Han, Young-Tak;Shin, Jung-Uk;Kim, Duk-Jun;Park, Sang-Ho;Park, Yoon-Jung;Sung, Hee-Kyung
    • ETRI Journal
    • /
    • v.25 no.6
    • /
    • pp.535-537
    • /
    • 2003
  • We propose a rigorous 2D approximation technique for the 3D waveguide structures; it can minimize the well-known approximation errors of the commonly used effective index method. The main concept of the proposed technique is to compensate for the effective cladding index in the equivalent slab model of the original channel waveguide from the modal effective index calculated by the nonuniform 2D finite difference method. With simulations, we used the proposed technique to calculate the coupling characteristics of a directional coupler by the 2D beam propagation method, and the results were almost exactly the same as the results calculated by the 3D beam propagation method.

  • PDF