• Title/Summary/Keyword: Equalization system

Search Result 376, Processing Time 0.021 seconds

Design of discriminant function for thick and thin coating from the white coating (백태 중 후태 및 박태 분류 판별함수 설계)

  • Choi, Eun-Ji;Kim, Keun-Ho;Ryu, Hyun-Hee;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2007
  • Introduction: In Oriental medicine, the status of tongue is the important indicator to diagnose one's health, because it represents physiological and clinicopathological changes of inner parts of the body. The method of tongue diagnosis is not only convenient but also non-invasive, so tongue diagnosis is most widely used in Oriental medicine. By the way, since tongue diagnosis is affected by examination circumstances a lot, its performance depends on a light source, degrees of an angle, a medical doctor's condition etc. Therefore, it is not easy to make an objective and standardized tongue diagnosis. In order to solve this problem, in this study, we tried to design a discriminant function for thick and thin coating with color vectors of preprocessed image. Method: 52 subjects, who were diagnosed as white-coated tongue, were involved. Among them, 45 subjects diagnosed as thin coating and 7 subjects diagnosed as thick coating by oriental medical doctors, and then their tongue images were obtained from a digital tongue diagnosis system. Using those acquired tongue images, we implemented two steps: Preprocessing and image analyzing. The preprocessing part of this method includes histogram equalization and histogram stretching at each color component, especially, intensity and saturation. It makes the difference between tongue substance and tongue coating was more visible, so that we can separate tongue coating easily. Next part, we analyzed the characteristic of color values and found the threshold to divide tongue area into coating area. Then, from tongue coating image, it is possible to extract the variables that were important to classify thick and thin coating. Result : By statistical analysis, two significant vectors, associated with G, were found, which were able to describe the difference between thick and thin coating very well. Using these two variables, we designed the discriminant function for coating classification and examined its performance. As a result, the overall accuracy of thick and thin coating classification was 92.3%. Discussion : From the result, we can expect that the discriminant function is applicable to other coatings in a similar way. Also, it can be used to make an objective and standardized diagnosis.

  • PDF

A Comparison of Symbol Error Performance for SC-FDE and OFDM Transmission Systems in Modeled Underwater Acoustic Communication Channel (모델링된 수중음향 채널환경에서 SC-FDE와 OFDM 전송방식의 심볼오율 비교)

  • Hwang, Ho-Seon;Park, Gyu-Tae;Joo, Jae-Hoon;Shin, Kee-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.139-146
    • /
    • 2018
  • Underwater acoustic communication can be applied to various area such as scientific, commercial and military survey using Autonomous Underwater Vehicles and Unmanned Underwater Vehicles. Underwater communication is studying very actively by advanced country like United States. But differ from wireless communication in the air, underwater acoustic communication has some difficult problems, ISI(Inter Symbol Interference) due to multipath and limit of transmission bandwidth due to slow propagation of sound wave. In this paper, SC-FDE and OFDM transmission system for the cancellation of ISI in conjunction with underwater acoustic channel modeling are applied to the underwater simulation of communication. The performance of these methods in the simulation guide to possibility of adopting in underwater acoustic communication algorithm. For this purpose, we compare SER performance of SC-FDE with that of OFDM for modelled underwater channel. Underwater channel is generated by Bellhop model. Simulation results show above 5dB SNR gain at 10-3 SER. And it demonstrate SC-FDE is efficient method for underwater acoustic communication.

Convergence Speed Improvement in MMA Algorithm by Serial Connection of Two Stage Adaptive Equalizer (2단 적응 등화기의 직렬 연결에 의한 MMA 알고리즘의 수렴 속도 개선)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2015
  • This paper deals with the mMMA (modified MMA) which possible to improving the convergence speed that employing the serial connecting form of two stage digital filter instead of signal filter of MMA adaptive equalizer without applying the variable step size for compensates the intersymbol interference by channel distortion in the nonconstant modulus signal. The adaptive equalizer can be implemented by signal digital filter using the finite order tap delay line. In this paper, the equalizer is implemented by the two stage serial form and the filter coefficient are updated by the error signal using the same algorithm of MMA in each stage. The fast convergence speed is determined in the first stage, and the residual isi left at the output of first stage output is minimized in the second stage filter. The same digital filter length was considered in single stage and two stage system and the performance of these systems were compared. The performance index includes the output signal constellation, the residual isi and maximum distortion, MSE that is measure of the convergence characteristics, the SER. As a result of computer simulation, mMMA that has a FIR structure of two stage, has more good performance in every performance index except the constellation diagram due to equalization noise and improves the convergence speed about 1.5~1.8 time than the present MMA that has a FIR structure of single stage.

Performance Analysis of the Channel Equalizers for Partial Response Channels (부분 응답 채널을 위한 채널 등화기들의 성능 분석에 관한 연구)

  • Lee, Sang-Kyung;Lee, Jae-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.8A
    • /
    • pp.739-752
    • /
    • 2002
  • Recently, to utilize the limited bandwidth effectively, the concept of partial response (PR) signaling has widely been adopted in both the high-speed data transmission and high-density digital recording/playback systems such as digital microwave, digital subscriber loops, hard disk drives, digital VCR's and digital versatile recordable disks and so on. This paper is concerned with adaptive equalization of partial response channels particularly for the magnetic recording channels. Specifically we study how the PR channel equalizers work for different choices of desired or reference signals used for adjusting the equalizer weights. In doing so, we consider three different configurations that are actually implemented in the commercial products mentioned above. First of all, we show how to compute the theoretical values of the optimum Wiener solutions derived by minimizing the mean-squared error (MSE) at the equalizer output. Noting that this equalizer MSE measure cannot be used to fairly compare the three configurations, we propose to use the data MSE that is computer just before the final detector for the underlying PR system. We also express the data MSE in terms of the channel impulse response values, source data power and additive noise power, thereby making it possible to compare the performance of the configurations under study. The results of extensive computer simulation indicate that our theoretical derivation is correct with high precision. Comparing the three configurations, it also turns out that one of the three configurations needs to be further improved in performance although it has an apparent advantage over the others in terms of memory size when implemented using RAM's for the decision feedback part.

An Analysis of Nursing Behavior and Unit of Treatment Cost of Non- Insurance Patients (종합병원의 비보험환자 처치행위 양상과 수가분석에 관한 연구)

  • 오세영
    • Journal of Korean Academy of Nursing
    • /
    • v.10 no.1
    • /
    • pp.41-55
    • /
    • 1980
  • The medical care insurance system, being put into practice nearly for three years, seem to have brought about some considerable problems as serious for the government as to consider a revision of that system. As one of the most serious problems of present system, the treatment cost of insurance patients is so remarkably low in comparison with than of non-insurance cases that normal operation of hospitals is threatened and care services of low quality are induced. The researcher carried out this survey to analyze and bring to light several aspects of treatment cost of non-insurance patients as a material for a re-assessment of the cost of insurance cases which shows a a considerable difference in amount at the standpoint of hospitals with than of non-insurance cases and further, hoping the significant blind spot of present insurance system(that is, the absence of regulations' for cost assessment by patterns or types of health care treatment) will be mended in near future. The survey was carried out with the treatment invoice sheets of total 902 in-hospital Patients of a general hospital in Seoul during the period of the 2 nd quarter of the year(1979). Among total 902 patients, 694 cases were used for analysis, because those disease or syndromes shared by less than 10% of the patients were put aside before procession. The data were analyzed by kinds or types of diseases, demographic characteristics of patients, hospitalization patterns, types of nursing treatment, etc. The result of analysis was as follows 1. Among all the non-insurance cases, those who received one or more kinds of nursing treatment mounted up to 96. 7 %. The invoice issue frequency per person was 7.2 times, while that frequency per day for a person was 0.8, : the treatment cosr per person was ₩22,650 while its daily average was ₩2,430, due to the average 9.3 in-hospital days per person. 2. As to the nursing treatment types by the demographic characteristics of patients and hospitalization patterns. a. The unit cost female patients was generally more expensive them that of males, and independent nursing service was more given than other types of treatment. As to age, higher age groups received independent nursing service most, while the youngest group received instrumental and integrated nursing services. b. As to room grade, the unit cost of I.C.U. cases was the highest : and the cast of private room patients was higher than that of public room patients. By in-hospital days, the curve of function showed L. type : that is, the longer stay, the lower function. 3. State of treatment types by kinds of disease were ; a. Dependent nursing service showed comparatively high availability in surgical and neurologic disease and independent nursing service was most received by medical, obstetrical and urological patients, while instrumental and integrated services were most available for respiratory disease and obstetrical and neurologic diseases next. b. The invoice issue frequency per day for a patient was highest in obstetrical disease 3.8 times, and the unit cost(per one invoice sheet) was also highest in obstertrical disease(₩10,880) and next in neurologic cases(₩ 4,690 ). 4. As to the pertained departments. a. Cost amount per person was highest in department of Psychiatries daily cost was highest in obstetrical cases : while the invoice issue frequency was highest in obstetrics and next in pediatrics. b. In departments in need of surgical operation, dependent nursing care was highly availabl : while in internal medicine and obstetrics, independent service was higher. Psychiatrics showed the highest the of integrate nursing while pediatrics and obstetrics higher of instrumental services. The variation co-efficien of treatment cost came out to be relatively in high in special surgery, opthalmology and internal medicine. 5. State of treatment cost by types of nursing behavior was. a. The average frequency of invoice issue was 3.5 (times). Among the type four types of treatment, instrumetal service (4.3) and independent nursing behavior(3.9) showed higher frequency than average respectively. But as to unit cost (per invoice). dependent (₩5,200) and integrated (₩5,340) nursing care services were higher than average and considerably higher than the other two types. b. In repect patient distribution. independent nursing behavior(80.3% ) was the highest and depend ent nursing (31.7% ) the lowest. The variation co-efficient of treatment cost appeared highest in dependent nursing be havior as a whole, and among that, doctor's diagnosis showed the highest coefficient value (100.7). In conclusion, the variaty of treatment cost(treatment itself ) by various characteristics and treatment types pro- that treatment various sort of patients and treatment cost of various types of nursing behavior cannot be uniform. Therefore, to attain the equalization of health care service and its cost both for insurant and non-insurant patients, a more specific provision for assessment of cost should be added to the present medical care insurance system and, in addition, the cost of nursing treatment is desired to be inserted into the treatment invoice.

  • PDF

Wavelet Transform-based Face Detection for Real-time Applications (실시간 응용을 위한 웨이블릿 변환 기반의 얼굴 검출)

  • 송해진;고병철;변혜란
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.9
    • /
    • pp.829-842
    • /
    • 2003
  • In this Paper, we propose the new face detection and tracking method based on template matching for real-time applications such as, teleconference, telecommunication, front stage of surveillance system using face recognition, and video-phone applications. Since the main purpose of paper is to track a face regardless of various environments, we use template-based face tracking method. To generate robust face templates, we apply wavelet transform to the average face image and extract three types of wavelet template from transformed low-resolution average face. However template matching is generally sensitive to the change of illumination conditions, we apply Min-max normalization with histogram equalization according to the variation of intensity. Tracking method is also applied to reduce the computation time and predict precise face candidate region. Finally, facial components are also detected and from the relative distance of two eyes, we estimate the size of facial ellipse.