• Title/Summary/Keyword: Environmental tests

Search Result 4,276, Processing Time 0.04 seconds

The Study on the Atmospheric Corrosion Tests of Materials in Northeast Asia (동북 아시아 지역에서의 대기중 재료부식 시험에 관한 연구)

  • 김선태;임봉빈
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.361-368
    • /
    • 1998
  • The structure such as building and cultural properties was composed of various materials like wood, metal and stone that have been utilized and exposed to air, wind and rain far a long time. However, because of their special characteristics as structure, collecting of samples that may involve their destruction cannot be permitted, ever for material analysis. Therefore, h order to study the Influence of atmospheric pollution on structure, atmospheric corrosion tests were achieved by making use of materials(bronze. ancient copper, copper, steel and marble) in field exposure tests. Atmospheric exposure sites are selected from places which are characterized by urban, rural, Industrial and marine enoronments In Northeast Asia. According to the results of atmospheric corrosion tests: The corrosion rates of Industrial states In china were more serious than other sampling sites. In the correlation of meteorological factors. wet hours was defiled as Intogeacted hours under that atmospheric temperature is above $0^{\circ}C$ and relative humidity in above 80% that has a great influence on corrosion tests of materials in case of a short time. The relative humidity was above about 75% that resulted in great increase of corrosion rates. In the esimation of corrosion rates between materials, corrosion rates of steel was about thirty times and decuple larger than that of other materials excluding marble in unshelterd exposure and In sheltered exposure.

  • PDF

Direct and Indirect Membrane Integrity Tests for Monitoring Microbial Removal by Microfiltration (정밀여과(MF)막 미생물 제거율 모니터링을 위한 막 완전성시험)

  • Hong, Seungkwan;Miller, Frank;Taylor, James
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.801-806
    • /
    • 2004
  • The pilot study was conducted to (i) investigate the ability of various membrane integrity monitoring methods to detect changes in membrane integrity during operation, and (ii) determine the impact of membrane damage on microbial removal by microfiltration. Two variations of air pressure hold tests were investigated for direct integrity monitoring: pressure decay (PD) and diffusive air flow (DAF) tests which are most commonly used integrity tests for microfiltration (MF) membranes. Both PD and DAF tests were sensitive enough to detect one damaged fiber out of 66,000 under field operaing conditions. Indirect integrity monitoring such as turbidity and particle counting, however, responded poorly to defects in membrane systems. Microbial challenge study was performed using both new and deliberately damaged membranes, as well as varying the state of fouling of the membrane. This study demonstrated that MF membrane with nominal pore size $0.2{\mu}m$ was capable of removing various pathogens including coliform, spore, and cryptosporidium, at the level required by drinking water regulations, even when high operating pressures were applied. A sharp decrease in average log reduction value (LRV) was observed when one fiber was damaged, emphasizing the importance of membrane integrity in control of microbial contamination.

An Environmental Test in Consideration of Cumulative Stresses of Supply Chain (Supply Chain 상의 중첩스트레스를 고려한 환경시험)

  • Lee, Dong-Hyuk;Jang, Joongsoon
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.118-124
    • /
    • 2016
  • Purpose: The purpose of this paper is to suggest an environmental test plan for reducing early failure. Methods: We study the preferred test design and tests that are performed substantially in the company. We investigate the environmental profile on the actual supply chain and identify the effectiveness for this test design. Results: Proposed sequential test designed to implement the supply chain on the environment profile showed more effective results compared to existing tests. Conclusion: Suggested sequential test in this paper will be an effective guidance for the given environment test.

Improvement of Cooling Water Quality by Corrosion and Scale Inhibitor (부식 및 스케일 억제제에 의한 냉각수 수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi
    • Journal of Environmental Science International
    • /
    • v.18 no.2
    • /
    • pp.187-195
    • /
    • 2009
  • This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of $80^{\circ}C$. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.

Environmental Tests of Kick Motor Safety and Arming Device (킥모터 점화안전장치 환경시험)

  • Koh, Hyeon-Seok;Kil, Gyoung-Sub;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.703-704
    • /
    • 2010
  • The environmental tests simulating the flight condition have been performed to manufacture the high reliable safety and arming device(SAD). A motor assay in preliminary design was reinforced with the structure to resist severe vibration and shock environment, and the design change had been verified by conducting the principal environmental test again.

  • PDF

A comparative study of three different viability tests for chemically or thermally inactivated Escherichia coli

  • Park, Seon Yeong;Kim, Chang Gyun
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.282-287
    • /
    • 2018
  • Three different methods of bacterial viability monitoring were compared to detect chemically or thermally inactivated Escherichia coli. Direct colony enumeration, live/dead bacterial cell staining with a fluorescent dye, and the dehydrogenase activity assay were compared with respect to their ease of use and time required to perform the three different tests. The green (live cell)/red (dead cell) ratio obtained from the fluorescent bacterial cell staining approach showed a linear relationship with the colony forming units; the result obtained with dehydrogenase was similar to those. The sensitivity of the monitoring methods to detect bacterial deactivation varied with different disinfection conditions. After thermal treatment, the sensitivity of the staining approach was lower, while that of the dehydrogenase activity assay was the highest. After chemical treatment, the sensitivity of detection for both methods was similar.

Determining the reuse of metal mine wastes based on leaching test and human health risk assessment

  • Ju, Won Jung;Hwang, Sun Kyung;Jho, Eun Hea;Nam, Kyoungphile
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.82-90
    • /
    • 2019
  • Meeting the regulations based on the short-term leaching tests may not necessarily assure the environmental and human health safety of reusing mine wastes. This study investigated heavy metal leachability of four metal mine waste samples (e.g., Z, Y, H, and M) and human health risk of reusing them as construction materials. The heavy metal leachability did not depend on the total heavy metal contents. For example, the Z sample contained greater amounts of As and Fe than Zn, but the leachates contained only Zn at a detectable level. This can be attributed to the crystalline structure and heavy metal fractions of the mine wastes. The leaching test results suggested that the four mine waste samples are potentially reusable. But the Z and M samples reused in industrial areas imposed carcinogenic risks. This was largely attributed to As that is exposed via dermal contact. The Y and H samples reused in residential areas imposed carcinogenic risk. The major exposure route was the ingestion of crops grown on the mine wastes and Cr was the major concern. The two-stage assessment involving leaching tests and risk assessment can be used to promote safe reuse of mine wastes.

Design and Tests of an Airship Pressurization System (비행선 여압장치 설계 및 시험)

  • Lee, Yung-Gyo;Kim, Dong-Min;Lee, Jin-Woo;Yeom, Chan-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1709-1714
    • /
    • 2004
  • Pressurization system of a 50m unmanned airship was manufactured according to the detailed design. In this paper. the whole procedures including system design. simulation and fabrication were described. The fabricated part were ground tested to check compliances with design requirements. Ground tests include operational tests, leakage tests, endurace tests and low temperature environmental tests. Results shows pressurization system of a 50m unmanned airship meets design requirements. Currently. pressurization system is installed to the KARI airship, Via 50m and performance verification through the flight tests are being conducted.

  • PDF

Development of Miniature Cone and Characteristics of Cone Tip Resistance in Centrifuge Model Tests (원심모형실험용 소형 콘 개발 및 콘 선단저항치 특성에 관한 연구)

  • Kim, Jae Hyun;Kim, Dong Joon;Kim, Dong Soo;Choo, Yun Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.631-642
    • /
    • 2013
  • The standard CPT(Cone Penetration Test), which can be easily performed to investigate in-situ soil engineering properties, has been widely used. CPT are also widely being utilized in centrifuge model tests. In this study, a miniature cone with 10mm diameter was developed and its applicability in the centrifuge was evaluated. The developed miniature cone was equipped with a four degree-of-freedom in-flight robot. A series of cone penetration tests was performed under four centrifuge acceleration levels. As results, the cone resistances measured at the same confining stress within shallow penetration depth were affected by the centrifugal accelerations. The critical depth was proportional to the cone diameter and relative density. Cone resistances results below the critical depth and soil parameters obtained from the laboratory tests were compared with those by previously proposed empirical relations.

Assessment of Korean Water Quality Standards for Effluent Discharged from the Dye Industry Based on Acute Aquatic Toxicity Tests Using Microbes and Macroinvertebrates (염색폐수의 수질독성시험을 이용한 한국의 수질배출허용기준 평가연구)

  • Kim, Young-Hee;Lee, Min-Jung;Choi, Kyung-Ho;Eo, Soo-Mi;Lee, Hong-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2004
  • Acute aquatic toxicity of effluents discharged from five dyeing plants in Gyeong-gi province were evaluated to assess whether the current Korean water quality standards(KWQS) could protect aquatic life. Chemical analyses of all parameters regulated under KWQS, except for E-coli, were also carried out to determine regulation compliance of the samples. All the effluent samples were satisfied with KWQS except for the color in only one sample. In acute Daphnia magna toxicity tests, significant mortality was observed in one of five samples and EC50 was 12.1%(95% confidence interval 9.1-16.2), which was in compliance with KWQS. The result of the Microtox assay indicated that acute microbial toxicity existed in effluents from three out of five plants, two of which were in compliance with KWQS. The agreement between regulation compliance of chemical concentrations of effluent and observed toxicity from various biological toxicity tests was very poor to fair (kappa = 0.194~0.250). The data presented suggest that exposure to dyeing wastewater which were in compliance with Korean water quality standards may not be safe to aquatic biota, and multiple tropical levels should be considered in aquatic toxicity monitoring of dyeing industry.