• Title/Summary/Keyword: Environmental standard

Search Result 4,709, Processing Time 0.032 seconds

A study on Investigation of Fecal Contamination Indicator Bacteria for Management of Source Water Quality (상수원 수질관리를 위한 분변오염 지표세균에 관한 연구)

  • 장현정;이용욱
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • Coliforms is currently being used as the standard of environmental water qualify to evaluate the level of source water quality especially condition of fecal contamination. However, not properly applied to water quality management. So in this study, in addition to Coliforms, fecal contamination indicator bacteria turk at Feral Coliforms(FC), E. coli, Fecal streptococci(FS), Clostridium and environmental parameters related with it's distribution were investigated on a monthly basis in 6 water intakes of Han River. The mean of BOD, DO, SS and pH, benchmarks of source water management were maintained the second grade of environmental water quality standard applied to Han River but Coliforms exceeded it. Distribution of Coliforms ranged from 1.0×10¹ to 2.7 10/sup 5/ CFU/ml, FC ranged from ND to 5.3×10¹ CFU/ml, E. coli ranged from ND to 9.2×10¹ CFU/ml, FS ranged from ND to 2.5×10¹CFU/ml, they were steepy rise on July and August in common when rainfalls was heavy and water temperature was high, but Clostridium perfringens ranged from 1.7×10¹to 1.7×10¹CFU/ml not fluctuate by month. Statistical analysis of sampling data showed that most significant correlations occurred among FC and Coliforms(r = 0.840), E. coli(r = 0.792), FS(r = 0.687) and environmental parameters(temperature, turbidity, SS, rotor were all r > 0.60) while no significant correlation was observed between ammonia generally recognized fecal contamination indicator and bacteria. Identification of the coliforms showed that Enterobacter, Klebsiella, Citrobacter were comprised of 32%, 24%, 16% respectively, and E. coli were 7% of it. while E. coli was made up 85.9% of FC. The mean value of FC/Coliforms ratio, 5.2(0.1-42) were higher in Amsa, Guui than Jayang. Fecal coliforms, as those are able to reflect more particularly the extent of the fecal contamination, were considered useful in deciding the level of water treatment while monitoring the fecal contamination from the source of water supply. Therefore, it is expected that the water quality is going to be managed more efficiently by using fecal coliforms supplementarily to total coliforms which are current standard item of water-quality environment.

The Economic Analysis of Notional and Global Interest Politics for International Environmental Standards

  • Hwang, Uk
    • Journal of Environmental Policy
    • /
    • v.6 no.4
    • /
    • pp.103-127
    • /
    • 2007
  • This study presents the political economics models to explore the political landscape of special interest groups influencing the government's decision making process for implementing international environmental standard. Starting with the popular menu-auction types of lobbying frameworks in the literature, the study extends its scope of research to multi-principal and multi-agency based international interest group politics and its hybrid case in order to bring the interaction of the relevant interest politics to the fore. Within a specific factor model of international trade between 2 small open economies, we compare the political equilibrium environmental standards in different institutional frameworks which can be feasible in the sense of recently growing role of environmental interest group. Although the conventional finding suggests that cooperative bargaining between the two countries can attain the globally optimal level of the standard, the paper rather explains that the cooperation between the national interest groups and the hybrid case also generate the stricter standard then national interest politics usually do.

  • PDF

Construction of Long-term Load Duration Curve Using MOVE.2 Extension Method and Assessment of Impaired Waterbody by Flow Conditions (MOVE.2 확장기법 적용을 통한 장기 부하지속곡선 구축 및 유황조건별 수체손상평가)

  • Kim, Gyeonghoon;Kwon, Heongak;Im, Taehyo;Lee, Gyudong;Shin, Dongseok;Na, Seungmin
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.51-62
    • /
    • 2017
  • The purpose of this study is to evaluate on the applicability of Load Duration Curve (LDC) method using Maintenance of Variance Extension types 2 method and sampling data for efficient total maximum daily loads at the Nakbon-A unit watershed in Korea. The LDC method allows for characterizing water quality data such as BOD, TOC, T-N and T-P in this study at different flow regimes(or quarters). BOD usually exceeded the standard value (exceedance probability 50%) at low flow zone. On the other hand, TOC, T-N, T-P usually exceeded the standard value at dry and low flow zone. Seasonally all water quality variables usually exceeded the standard value at Q1(Jan-Mar) and Q2(Apr-Jun) zones. Improvement of effluent control from wastewater treatment plants are effective to improve BOD and T-P.

Analytical Method of Polycyclic Aromatic Hydrocarbons (PAHs) in Petroleum Contaminated Soils - Focused on the 16 US EPA Priority PAHs (유류오염토양 중 다환방향족탄화수소류(PAHs) 분석방법 연구 - US EPA 16종 PAHs를 중심으로)

  • Kim, Ji Young;Kim, Dongho;Kim, Tae Seung;Han, Jin-Suk;Lee, Jai-Young;Noh, Hoe-Jung
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.5
    • /
    • pp.20-30
    • /
    • 2012
  • In case of analyzing PAHs (EPA 16 compounds) in oil-contaminated soils, the lump of peaks may occur because of the aliphatic and polar compounds in oil. This phenomenon is due to the lower accuracy of the analysis. To solve this problem, evaluation of application of silicagel-alumina multi-layer fraction was performed using standard substances and oil-contaminated soils. As a result of application of silicagel-alumina multi-layer fraction cleanup method using standard substances, recovery rates of surrogate standards (5 compounds including Naphthalene-d8) were 83~100% and those of target standards were 75~129%. These were to meet the target values (60~130%) in this study. When used 4% water-silicagel column analyze PAHs in oil-contaminated soils, Some problems were generated for quantitative analysis of PAHs; concentration of PAHs was underestimated due to an upward baseline of internal standard (recovery rate: less than 60%) and overestimated by the lump of peaks which were not purified (the biggest recovery rate: more than 400%). On the other hand, in case of silicagel-alumina multi-layer fraction cleanup method, recovery rate of surrogate standards were 61~101.6%. Therefore this cleanup method was considered a valid method to improve accuracy of analysis of PAHs in oil-contaminated soils.

A Study on the ISO 14000' Trend and its Application Effect (ISO 14000의 동향과 효과에 관한 연구)

  • Myung, Chang-Sig
    • Korean Business Review
    • /
    • v.14
    • /
    • pp.77-93
    • /
    • 2001
  • The ISO issued the first standard for environmental management standard(EMS) in 1993. This standard provide for elements of an effective environmental management system and can also help companies ingrain effective environmental management practice into their overall business operations. ISO 14001 is predicted to become the leading voluntary environmental management system standard. Companies selling products and services internationally and domestically will also be affected by publication of this standard. Especially, this new environmental management standards are fast becoming a condition for doing global business because it can be acted with trade barriers. Actually, an automobile companies of America including Ford and GM require their subcontracting companies to gain the recognition of ISO 14001. The purpose of this paper is to investigate the ISO 14000 and its application of Korean firms focusing on environmental management system(EMS). This paper proceeds to present the effective alternatives through analysing the existing Korean firms which has established EMS. Korean firms should adopt EMS not for the enhancement of corporate image but for the purpose of strategic competitive advantage.

  • PDF

A Microbiological Study on the Tap Water in Seoul (서울시 수도수 중의 위생물학적 조사연구)

  • 조영채
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.33-41
    • /
    • 1981
  • This study was carried out to investigate Water Temperature, Residual Chlorine, Coliform Groups, and the Standard Plate Counts of Water Supply Areas provided by 7 Water Purification Plant (W.P.P) in Seoul from September 20, 1979 through October 20, 1979. The results were summarized below: 1) The mean water temperature of the 63 Water Samples was 19.8$\circ$C, the mean pH 7.18, and the mean residual chlorine concentration 0.52 ppm by each Water Supply Areas. There is no statistically significant differences between the WPP Areas, but there is significant differences between water supply areas. 2) 30(47.6%) out of the 63 Water Samples were Standard Plate Counts free and 33 Samples (52.4%) were contaminated by Standard Plate Counts. 30 (47.6%) out of 33 samples showed the existence of Standard Plate Counts less than 15 and the other 3 samples 15-30. 3) 2 (3.2%) out of the 63 Samples had the coliform. Those 2 Samples had 2 and 6 coliform group counts per 50ml respectively both of them were 0.1ppm in residual chlorine. 4) There is correlation among Water Temperature, pH, Residual Chlorine, Standard Plate Counts, and Coliform Groups. The Coefficient of Correlation(r) between Water Temperature & Residual Chlorine was 0.147, 0.240 between Water Temperature & Standard plate Counts and 0.215 between pH & Standard Plate Counts. These correlations are statistically no significant, But the correlation of coefficient between pH & Residual Chlorine was -0.291 which is showed significant correlation at p<0.05. The coefficient of correlation between Residual Chlorine & Standard Plate Counts was -0.441 which is showed Negative Correlation Statistically Significant difference at p<0.01.

  • PDF

A Study on the Measures to Improve the Assessment Method for Loss Compensation of Landscape Plants (조경수의 손실보상 감정평가 개선에 관한 연구)

  • Park, Yool-Jin;Lim, Yoen-Hong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.3
    • /
    • pp.19-31
    • /
    • 2017
  • Plants are the basis for sustainable green growth, and the value of existence and importance of trees including landscape Plants can't be emphasized enough. Therefore, they are precious living things thriving in all sorts of public services, and continuous civil complaints for justifiable compensation of landscape Plants are filed. First, the standard formula of planting intervals according to production target specifications is calculated using root-collar caliper and diameter at breast height, and apply (1) standard medium sized trees which have not yet reached commercialization [deciduous tree production goal (R(B) less than 6cm]= (target standard)= [target standard $R(cm){\times}15{\times}0.7$]. (2) In case of commercialization(R6~R10)= [target standard $R(cm){\times}15{\pm}5%$], (3) In case of more than R12= [target standard $R(cm){\times}15{\times}130%$] shall be applied. In case of using diameter at breast height (4) In case of commercialization(B6~B10)= [target standard $B(cm){\times}20{\times}15{\pm}5%$], (5) In case of more than B12= [target standard $B(cm){\times}20{\times}130%$] shall be applied. Second, appraisal methods based on tree classification of compensation for loss are classified according to planted locations. (1) landscape trees within a house=[price of arrival at the site+planting cost], (2) landscape trees in places such as arboretum=[management technology of tress + relocation expenses considering scarcity of the trees (3) landscape trees in a place of loads= [landscape tree production cost + work out added price. In case of producted landscape threes (4) landscape trees ready to be commercialized as sales loss.

Development of Enhanced Analytical Method for Perchlorate in Food by IC-MS/MS with an Internal Standard (IC-MS/MS와 내부표준물질을 이용한 식품 중 perchlorate 분석법 개선)

  • Yang, Min-June;Kim, Jong-Sung;Han, Jong-Hun;Her, Nam-Guk
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.532-536
    • /
    • 2011
  • The internal standard method using ion chromatography combined with tandem mass spectrometry (IC-MS/MS) for quantifying perchlorate in different types of food was established. Because the presence of ions and other biomolecules in matrices usually interrupts accurate determination of perchlorate, it is necessary to develop efficient, reproducible method to determine perchlorate concentrations in food. In this study, the internal standard method was compared with the external standard method to determine perchlorate concentrations in standard samples. The obtained method detection limit (MDL) for perchlorate was 0.005 ${\mu}g/L$ for bottled water, 0.12 ${\mu}g/L$ for milk, 0.27 ${\mu}g/kg$ for rice, 0.16 ${\mu}g/kg$ for vegetables, and 0.07 ${\mu}g/kg$ for seaweed, respectively. The limit of quantitation (LOQ) was calculated by multiplying the MDL by 7. The recoveries of perchlorate from food samples spiked with perchlorate ranged from 98 to 105% and their percent relative standard deviation (%RSD) levels were <20%. This method was successfully applied for the quantitative determination of perchlorate in various kinds of food.

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

Applicability of Huff Model & ABM Method for Discharge Capacity of Sewer Pipe (하수관거 통수능 해석을 위한 Huff 모형과 ABM 법의 적용성 분석)

  • Hyun, Inhwan;Jeon, SeungHui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.229-237
    • /
    • 2022
  • The sewer capacity design have been based on the Huff model or the rational equation in South Korea and often failed to determine optimal capacity, resulting in frequent urban flooding or over-sizing. A time distribution of rainfall (i.e., Huff or ABM method) could be used instead of a rainfall hyetograph obtained from statistical analysis of previous rainfalls. In this study, the Huff method and the ABM method, which predict the time distribution of rain intensity, which are widely used to calculate sewage pipe drainage capacity using the SWMM, were compared with the standard rainfall intensity hyetograph of Seoul. If the rainfall duration was 30 minutes to 180 minutes, the rainfall intensity value calculated by the Huff model tended to be less than the rainfall intensity value of the standard rainfall intensity in the initial 5-10 minutes. As a result, more than 10% to 30% of under-design would be made. In addition, the rainfall intensity value calculated by the Huff model from the section excluding the initial 5-10 minutes of rainfall to the rainfall duration was calculated larger than the value using the standard rainfall intensity equation, which would result in an over-design of 10% to 30%. In the case of a relatively long rainfall duration of 360 minutes (6 hours) to 1,440 minutes (24 hours), it showed an lower rainfall intensity of 60 to 90% in the early stages of rainfall, but the problem of under-design had been solved as the rainfall duration time had elapsed. On the other hand, in the alternating block method (ABM) method, it was found that the rainfall intensity at the entire period at each assumed rainfall duration accurately matched the standard rainfall intensity hyetograph of Seoul.