• Title/Summary/Keyword: Environmental Sample

Search Result 2,584, Processing Time 0.027 seconds

Cross Correlations between Probability Weighted Moments at Each Sites Using Monte Carlo Simulation (Monte Carlo 모의를 이용한 지점 간 확률가중모멘트의 교차상관관계)

  • Shin, Hong-Joon;Jung, Young-Hun;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.3
    • /
    • pp.227-234
    • /
    • 2009
  • In this study, cross correlations among sample data at each site are calculated to obtain the asymptotic cross correlations among probability weighted moments at each site using Monte Carlo simulation. As a result, the relations between the asymptotic cross correlations among probability weighted moments and the inter-site dependence among sample data at each site are nearly a linear relation with slope 1. The smaller ratio of concurrent data size to entire sample size is, the weaker the relationship grows. Simple power function which the correction term in power function accounts for the differences of the sample size between two sites was fitted to each case to estimate the parameter. It is noted that this result can be used in the various researches which include the estimation of the variance of quantile considering cross correlations.

A Case Study about Counting Uncertainty of Radioactive Iodine (131I) in Public Waters by Using Gamma Spectrometry (감마분광분석을 이용한 환경 중 방사성요오드(131I)의 측정 불확도에 관한 사례 연구)

  • Cho, Yoonhae;Seol, Bitna;Min, Kyoung Ok;Kim, Wan Suk;Lee, Junbae;Lee, Soohyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • The radioactive iodine ($^{131}I$) presents in the environment through the excrete process of nuclear medicine patients. In the detecting of low level of $^{131}I$ in the public water, the counting uncertainty has an effect on the accuracy and reliability of detecting $^{131}I$ radioactivity concentration. In this study, the contribution of sample amount, radioactivity concentration and counting time to the uncertainty was investigated in the case of public water sample. Sampling points are public water and the effluents of a sewage treatment plant at Sapkyocheon stream, Geumgang river. In each point, 1, 10 and 20 L of liquid samples were collected and prepared by evaporation method. The HPGe (High Purity Germanium) detector was used to detect and analyze emitted gamma-ray from samples. The radioactivity concentration of $^{131}I$ were in the range of 0.03 to 1.8 Bq/L. The comparison of the counting uncertainty of the sample amount, 1 L sample is unable to verify the existence of the $^{131}I$ under 0.5 Bq/L radioactivity concentration. Considering the short half-life of $^{131}I$ (8.03 days), a method for measuring 1 L sample was used. However comparing the detecting and preparing time of 1, 10 L respectively, detecting 10 L sample would be an appropriate method to distinguish $^{131}I$ concentration in the public water.

The Characteristic of Te Recovery in Gold Concentrate Using Electrolysis (전기분해법을 이용한 금정광내 Te 회수 특성)

  • Kim, Bong-Ju;Cho, Kang-Hee;Jo, Ji-Yu;Choi, Nag-Choul;Park, Cheon-Young
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.645-655
    • /
    • 2014
  • In order to obtain pure metallic Te from gold concentrate, roasting treatment, hypochlorite leaching, Fe removal and electrolysis experiments were carried out. The contents of Au, Ag and Te from the concentrate sample and roasted sample were much more soluble in the hypochlorite solution than in aqua regia digestion, whereas the metals Pb, Zn, Fe and Cu were easier to leach with the aqua regia than the hypochlorite. With the addition of NaOH in the hypochlorite leaching solution prior to electrolysis, the Fe removal rate achieved was only 96% in the concentrate sample, while it reached 98% in the roasted sample. The results of electrolysis for 240 min, 98% of the metallic copper was recovered from the concentrate sample, while 99% was obtained from the roasted sample due to the removal of S by roasting. The amount of anode slime was also greater in the electrolytic solution with the roasted sample than with the concentrate sample. The results on the anode slime after the magnetic separation process showed the amount of metallic pure native tellurium recovered was greater in the roasted sample than in the concentrate sample.

Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos (공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교)

  • Jang, Bong-Ki;Tak, Hyun-Wook;Song, Su-Jin;Jo, Bong-Hyun;Kim, Yeong-Ji;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

Establishing of a rapid analytical method on uranium isotopic ratios for the environmental monitoring around nuclear facilities (원자력 시설 주변 환경 감시를 위한 토양 중 우라늄 동위원소 신속 분석법 확립)

  • Park, Ji-Young;Lim, Jong-Myoung;Lee, Hyun-Woo;Lee, Wanno
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.134-142
    • /
    • 2018
  • The uranium isotopic ratio in environmental samples around nuclear facilities is important because it reveals information regarding illegal activities or anthropogenic pollution. Determination of uranium isotopes, however, is a challenging task requiring much labor and time because of the complex separation procedures and lengthy process. In this study, a rapid determination method for uranium isotopes in environmental samples was developed using. The sample was completely decomposed using the alkali fusion method. The separation procedure using extraction chromatography (UTEVA) was simplified in a single step without any further removal process for Si and major matrix elements. The established method can be completed within 3 h from sample dissolution to ICP-MS measurement. Most matrix elements and uranium isotopes in the soil samples were well separated and purified. Five types of were used to assess the method's accuracy and precision for a rapid uranium analysis method. The analytical accuracy for all CRM samples ranged from 95.1 % to 97.8 %, and the relative standard deviation was below 3.9 %. From the analytical results, one may draw conclusions that the evaluated method for uranium isotopes using alkali-fusion, the extraction chromatography process, and ICP-MS measurements is fast and fairly reliable owing to its recovering efficiencies. Thus, it is expected that the evaluated method can contribute to the improvement of environmental monitoring ability.

Analytical Methodology of Stable Isotopes Ratios: Sample Pretreatment, Analysis and Application (안정동위원소비 분석 기법의 이해: 시료의 전처리, 분석 및 자료의 해석과 적용)

  • Kim, Min-Seob;Hwang, Jong-Yeon;Kwon, Oh-Sang;Lee, Won-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.4
    • /
    • pp.471-487
    • /
    • 2013
  • This review paper was written to provide background information as well as future application for aquatic ecologists interested in using stable isotope. Stable isotope techniques has proved to be an extremely useful to elucidate a lot of environmental and ecological problems. Stable isotopes have been used as possible tracers to identify sources, to quantify relative inputs in a system. When utilized carefully, stable isotope tools provides apparent advantages for the scientists to find out the processes of material cycles in various environments and energy flows in natural ecosystems.

Purification of Waste Organic Solvent Containing Propylene Glycol Monomethyl Ether Acetate (PGMEA) (PGMEA를 포함하는 폐유기용제의 정제)

  • Yoon, Kyoung-Jin;Lee, Woong-Mok;Kwon, Oh-Hoon;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.616-620
    • /
    • 2010
  • This study was performed to recycle Propylene Glycol Monomethyl Ether Acetate (PGMEA) from Liquid Crystal Display (LCD) industry emission as a waste organic solvent by using a multistage distillation column and tried to decide optimum reflux ratio. From the final experiment result, it was confirmed ; in case the sample A, the PGMEA purity is more than 98% and the moisture is less than 0.05%, on the other hand, in case the sample B, the PGMEA purity is more than 95% when the reflux ratio is 6 and the moisture is less than 0.01% (Refer to Table 1 for the contents of sample A and B). These values means fine level which can be adapted in the LCD manufacture, requiring more than 90% common purity of recycling level.