• Title/Summary/Keyword: Environmental Quality Evaluation

Search Result 1,244, Processing Time 0.024 seconds

Evaluation on Actual Condition and Image Analysis of Roof Garden in Seoul, Korea (서울시 옥상농원의 실태분석 및 이미지 평가에 관한 연구)

  • Kong, Min-Jae;Park, Kwang-Lai;Son, Jin-Kwan;Shin, Ji-Hoon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.5
    • /
    • pp.69-83
    • /
    • 2012
  • Urbanization has caused increase of traffic jams, food shortage, housing, and environmental pollution in the world in recent decades. Urban agriculture, such as roof garden, can relieve the phenomenon of urban heat island causing from the urbanization. The study was conducted to investigate the characteristics of rooftop garden (farm) in 40 areas in Seoul, Korea, where the 'cabbage', 'lettuce', 'pepper', and 'mini-tomatoes' were the most preferred vegetables and fruit. The problems in the rooftop garden during a cultivation was observed for drainage system, soil management, cost or quality of planting mat and diseases and insects. The image of urban agriculture showed a positive words, such as 'bright', 'clean', 'open' and 'good' according to the survey.

Study on The Use of Teaching Area's Courtyard Space : Results from a Survey of Universities in Tai' an

  • Zhang, Xin-Peng;Wang, Wen-Li;Piao, Yong-Ji;Cho, Tae-Dong
    • Journal of Environmental Science International
    • /
    • v.24 no.5
    • /
    • pp.689-697
    • /
    • 2015
  • Based on the survey of 4 universities in Tai' an by questionnaire survey and interviews, this study acquired and analyzed the college student users' activity type, utilization frequency, retention time, companion, preference for landscape design style, the importance of the courtyard space's environment and landscape, as well as correlations between primary attributes and activity characteristics of student users. The weight of the university teaching area's courtyard space evaluation index was obtained by Analytical Hierarchy Process. The results indicated that nearly 60% college students select to study and to rest alone as the main activity type, 80% students' utilization frequency is at least two times or more a week. In addition, the relative weight of plant landscape is the highest in the 2nd class indexes of space garden landscape, and its value is 0.113; the relative weight of cleanliness is the highest in the 3rd class indexes of space environment quality, and its value is 0.143. Therefore, it should be attached much importance to constructing the environment and landscape for studying and relaxing, and the factors of cleanliness and plant landscape etc in the further design of courtyard space are taken into full consideration.

Evaluation of Airborne and Surface Lead Concentrations in Preschool Classroom (유아교육시설의 표면 및 공기 중 납 농도 평가)

  • Yoon, Chung-Sik;Paik, Do-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.1-7
    • /
    • 2006
  • This study was performed to investigate airborne lead concentration and surface lead contents in preschool facilities. Arithmetic mean of indoor lead concentration in urban area was $44.7\;ng/m^3$ (Geometric mean $32.1\;ng/m^3$) whereas outdoor concentration was $39.5\;ng/m^3$ (GM $22.8\;ng/m^3$). In rural area, airborne lead concentrations were $14.2\;ng/m^3\;(GM\;7.9 ng/m^3),\;12.6\;ng/m^3\;(GM\;5.6 ng/m^3)$, respectively. There is statistical significance of the lead concentrations among the locations of preschool facilities. About $37\%$ of qualitative lead check samples was positive and mainly was found in lead based paint. Though lead concentrations on the floor and window sill were well below the US EPA and HUD standard (floor $40\;{\mu}g/ft^2\;(4.3\;{\mu}g/100\;cm^2)$, window sill $250\;{\mu}g/ft^2\;(26.9\;{\mu}g/100\;cm^2)$, respectively), there were much samples which exceed the standard, i.e., $29\%$ of surface wall, $20\%$ of the desk and chair, $100\%$ of painted wood box of tested samples. In view of our study and hazard of lead to children, we recommended that the contents of lead in preschool facilities should be lowered as possible.

Real-time Water Quality Prediction for Evaluation of Influent Characteristics in a Full-scale Sewerage Treatment Plant (하수처리장 유입수의 특성평가를 위한 실시간 수질예측)

  • Kim, Youn-Kwon;Chae, Soo-Kwon;Han, In-Sun;Kim, Ju-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.6
    • /
    • pp.617-623
    • /
    • 2010
  • It is the most important subject to figure out characteristics of the wastewater inflows of sewerage treatment plant(STP) when situation models are applied to operation of the biological processes and in the automatic control based on ICA(Instrument, Control and Automation). For the purposes, real-time influent monitoring method has been applied by using on-line monitoring equipments for the process optimization in conventional STP. Since, the influent of STP is consist of complex components such as, COD, BOD, TN, $NH_4$-N, $NO_3$-N, TP and $PO_4$-P. MRA2(Microbial Respiration Analyzer 2), which is capable of real-time analyzing of wastewater characteristics is used to overcome the limitations and defects of conventional online monitoring equipments in this study. Rapidity, accuracy and stability of developed MRA2 are evaluated and compared with the results from on-line monitoring equipments for seven months after installation in Full-scale STP.

A Study on the Equipment Type of Stream Purification System that Applies Combined Physicochemical and Biological Treatment (물리·화학적 및 생물학적 처리가 결합된 장치형 하천정화 시스템에 관한 연구)

  • Eom, Han Ki;Kim, Sung Chul;Kim, Sung Su;Kim, Sam Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.273-281
    • /
    • 2017
  • The objective of this study is to evaluate the performance of stream purification equipment system combined MBP (Micro Bubble Process) and AGBP (Aerobic Granular Biofilm Process). Based on results, the optimal HRT (Hydraulic Retention Time) of MBP and AGBP set as 0.72 and 2.4 h, respectively. In the results of continuous operation on combined MBP and AGBP, it is possible to achieve a BOD, TSS and T-P removal efficiency of 85, 90 and 94%, respectively. It also confirmed that the water quality of the stream can be purified with increasing circulation flow through water simulation evaluation applied the QUAL-NIER model. Consequently this purification system can resolve the stream purification and dry stream problem.

A Study on Evaluation of Environmental Characteristics of Maternity Room (산후관리시설의 산모실 환경특성평가에 관한 연구)

  • Hwang, Yeon-Sook;Son, Yeo-Rym
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.6
    • /
    • pp.47-55
    • /
    • 2007
  • The purpose of this study is to evaluate environmental characteristics of maternity rooms. The method of this study is a field survey on 8 samples of postpartum care centers in Seoul. The plan, colors, materials, furniture and environmental characteristics of maternity rooms are analyzed. The characteristics of maternity rooms environment were categorized into four items; comfort, privacy, communication and dwelling. The results are as follows: Western-style and rooming-separation system of maternity rooms are used. Maternity rooms are generally good for dwelling quality but insufficient for communication. There are a lack of supply to control a temperature Individually in maternity rooms. It demands to make the type of one-sided public space between maternity room and living room for privacy. All of the maternity rooms surveyed are furnished with TV, radio, and telephone but, to improve communication with visitors, it is recommended that more convenient supplies such as audio and video system, chairs, and table be equipped. There are needs for sky-light windows in maternity rooms. It is necessary to research more about the space of living room, nursing room and service area, and we need more study about baby, nurser and owner' spaces.

Evaluation of Physical, Mechanical Properties and Pollutant Emissions of Wood-Magnesium Laminated Board (WML Board) for Interior Finishing Materials

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.86-94
    • /
    • 2020
  • This study serves as basic research for the development of a new wood-based building finishing material that improved the weakness of inorganic materials such as gypsum board and magnesium board widely used as interior finishing materials and brought out the strength of the wood. The results of evaluating the physical and mechanical properties and the environmental effect related to hazardous substance discharge having manufactured a wood-magnesium laminated composite are as follows. The thermal conductivity and thermal resistance of WML board was improved by about 28~109 percent over magnesium board due to the low thermal conductivity of wood. The adhesive strength of WML board showed a similar result to that of plywood as it exceeds 0.7N/㎟, the adhesive standard of wood veneer which is presented by KS F 3101. Bending strength and screw holding strength were more improved by manufacturing WML board than magnesium board. The WML board manufactured in this study satisfied the criteria for emissions of hazardous substances prescribed in the Indoor Air Quality Control Act, and confirmed the possibility of development as a new wood-based composite material that can replace existing inorganic materials.

Evaluation of the Troposphere Ozone in the Reanalysis Datasets: Comparison with Pohang Ozonesonde Observation (대류권 오존 재분석 자료의 품질 검증: 포항 오존존데와 비교 검증)

  • Park, Jinkyung;Kim, Seo-Yeon;Son, Seok-Woo
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.53-59
    • /
    • 2019
  • The quality of troposphere ozone in three reanalysis datasets is evaluated with longterm ozonesonde measurement at Pohang, South Korea. The Monitoring Atmospheric Composition and Climate (MACC), European Centre for Medium-Range Weather Forecasts Interim Reanalysis (ERAI) and Modern Era Retrospective-Analysis for Research and Applications version 2 (MERRA2) are particularly examined in terms of the vertical ozone structure, seasonality and long-term trend in the lower troposphere. It turns out that MACC shows the smallest biases in the ozone profile, and has realistic seasonality of lower-tropospheric ozone concentration with a maximum ozone mixing ratio in spring and early summer and minimum in winter. MERRA2 also shows reasonably small biases. However, ERAI exhibits significant biases with substantially lower ozone mixing ratio in most seasons, except in mid summer, than the observation. It even fails to reproduce the seasonal cycle of lower-tropospheric ozone concentration. This result suggests that great caution is needed when analyzing tropospheric ozone using ERAI data. It is further found that, although not statistically significant, all datasets consistently show a decreasing trend of 850-hPa ozone concentration since 2003 as in the observation.

Consideration on Application of Zooplankton Index for Wetland Ecosystem Evaluation (습지생태계 평가를 위한 동물플랑크톤 지수 적용 방안 고찰)

  • Hyun-Woo Kim
    • Korean Journal of Ecology and Environment
    • /
    • v.57 no.1
    • /
    • pp.51-59
    • /
    • 2024
  • This note summarizes the application of zooplankton indices for water quality management and estimation based on main research topics of articles focusing on wetland ecosystems, topics that are remained poorly investigated in S. Korea. The aquatic ecosystem-based consists of indices that respond to different target environmental factors, including environmental disturbance. Among the major indicator species and biota, we reviewed that management strategy for the wetland environment has to be focused more on small-sizes, in terms of zooplankton ecology and indices. The ecology of zooplankton communities in freshwater ecosystem has been the focus of an increasing number of studies since 2019, and considerable progress has been made in understanding the major mechanisms involved in regulating their abundance, diversity and spatio-temporal patterns. Even though studies on the freshwater ecosystem in Korea have a long history, a few of studies on zooplankton biota were conducted at wetlands. We suggested the candidate zooplankton indices proposed by the U.S. EPA and EU to suit Korean conditions. In the step of selecting metrics, the best available metrics are species-related variables, such as composition and abundance, as well as richness and diversity. Overall, in spite of several limitations, the development of a plankton-based multivariate assessment method in Korea wetlands is possible using mostly field research data. Later, it could be improved based on qualitative metrics on zooplankton, and with the emergence of further survey data. The present information can be used as basic information for researchers who are dealing with aquatic environments and its interaction with organisms.

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.