• 제목/요약/키워드: Environmental Quality Evaluation

검색결과 1,244건 처리시간 0.023초

Evaluation of Drinking Water Treatment Efficiency according to Regeneration Temperatures of Granular Activated Carbon (GAC) (입상활성탄 재생온도에 따른 정수처리 효율 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Jung, Jong-Moon;Ryu, Dong-Choon;Yoo, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • 제24권9호
    • /
    • pp.1163-1170
    • /
    • 2015
  • This study carried out continuous column test for estimating the regeneration efficiency with regeneration times and temperatures. More times regenerated granular activated carbon (GAC) has more ash in the GAC and has less apparent density. Two times regenerated GAC ($2^{nd}$ re-GAC) could removed the Trihalomethanes (THMs) in the water for the first two week after starting continuous column test, on the other hand five times regenerated GAC ($5^{th}$ re-GAC) did not have adsorption capacity. The THMs concentration in the effluent was almost equal or higher than that of influent at the first time of continuous column test. $2^{nd}$ re-GAC showed much more DOC adsorption capacity than $5^{th}$ re-GAC and the GAC which was regenerated with $700^{\circ}C$ had highest DOC removal efficiency among the GACs with 600, 700, 800, $900^{\circ}C$ regeneration temperatures. It is anticipated the cost of GAC regeneration could be saved more 100 million won by reducing the furnace temperature of 3rd~4th and 5th~6th about $150^{\circ}C$ compared to the current regeneration condition.

Variation of Water Quality around the Chudong Intake Tower in Daechung Reservoir (대청호 추동취수탑 부근의 수질변화 특성)

  • Ma, Xin-Chao;Lim, Bong-Su;Heo, Soon-Uk;Kwak, Mi-Ae
    • Journal of Korean Society on Water Environment
    • /
    • 제31권6호
    • /
    • pp.637-643
    • /
    • 2015
  • This study has been carried out to provide the basic data obtained from the evaluation of the variation of water quality around the Chudong intake tower in Daechung resevoir, which may be able to help the establishment of a pure water supply policy. Five sites around the Chudong intake tower were selected, and the average data for recent ten years(from year 2004 to year 2013) were analysed. The average water quality around Chudong intake tower are as followed; pH 7.5, DO 8.7 mg/L, BOD 1.0 mg/L, COD 3.0 mg/L, SS 3.0 mg/L, TN 1.495 mg/L, TP 0.017 mg/L, and Chlorophyll-a 6.5 mg/m3 were matched the good class by comparing with the living environment standard of reservoir. COD values of higher than 3.0 mg/L after July were likely due to non-point pollutants and algae outbreak during rainy summer season. Total phosphorus rose sharply in the summer season, and then algae watch was issued consistently for average 40 days. Total nitrogen to total phosphorus ratio was average 90, and it is important to control the inflow phosphrous from small stream for proper management to block an algae growth according to eutrophication. It was recommended to operate the algae removing boats around intake tower from July to October, and was required advanced water treatment processes to remove NBD COD and bad odor and taste due to algae growth.

Characteristics of Formation of Chlorination Disinfection By-Products in Extracellular Organic Matter of Various Algal Species (다양한 조류종들의 세포외 유기물질에서의 염소 소독부산물 생성 특성)

  • Son, Hee-Jong;Park, Hong-Ki;Hwang, Young-Do;Jung, Jong-Moon;Kim, Sang-Goo
    • Journal of Environmental Science International
    • /
    • 제24권4호
    • /
    • pp.541-547
    • /
    • 2015
  • Formation of disinfection by-products (DBPs) including trihalomethans (THMs) and haloacetic acids (HAAs) from chlorination of six different species (Chlorella vulgaris, Scenedesmus sp., Anabaena cylindrical, Microcystis aeruginosa, Asterionella formosa and Aulacoseira sp.) of algal extracellular organic matter (EOM). The EOM characteristics evaluation of six algal species reaching at the stationary phase in the growth curve showed most of its SUVA254 showed below 1 and this means hydrophilic organic matter is much higher than hydrophobic organic matter. Chloroform formation potential (CFFP), dichloroacetic acid formation potential (DCAAFP) and trichloroacetic acid formation potential (TCAAFP) were mainly composed of THMFP and HAAFP in the EOM of various algal species. In the case of THMFP/DOC and HAAFP/DOC values, EOM of blue-green algae has appeared highest and EOM of green algae and diatom in order. THMFP/DOC was higher than HAAFP/DOC in EOM of blue-green algae. In comparison of formation potential by unit DOC composed of HAAFP in algal species EOM, DCAAFP/DOC was 1.5 times to 7.5 time higher than TCAAFP/DOC in the EOM of blue-green algae, while DCAAFP/DOC was found to be relatively high compared to TCAAFP/DOC in the EOM of green algae and diatom.

Evaluation of Coagulation Characteristics of Fe(III) and Al(III) Coagulant using On-line Monitoring Technique (On-line 모니터링 기법을 이용한 Al염계와 Fe염계 응집제의 응집특성 평가)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Kim, Sang-Goo;Seo, Chang-Dong;Hwang, Young-Do
    • Journal of Environmental Science International
    • /
    • 제23권4호
    • /
    • pp.715-722
    • /
    • 2014
  • Effects of coagulation types on flocculation were investigated by using a photometric dispersion analyzer (PDA) as an on-line monitoring technique in this study. Nakdong River water were used and alum and ferric chloride were used as coagulants. The aim of this study is to compare the coagulation characteristics of alum and ferric chloride by a photometric dispersion analyzer (PDA). Floc growing rates ($R_v$) in three different water temperatures ($4^{\circ}C$, $16^{\circ}C$ and $30^{\circ}C$) and coagulants doses (0.15 mM, 0.20 mM and 0.25 mM as Al, Fe) were measured. The floc growing rate ($R_v$) by alum was 1.8~2.8 times higher than that of ferric chloride during rapid mixing period, however, for 0.15 mM~0.25 mM coagulant doses the floc growing rate ($R_v$) by ferric chloride was 1.1~2.3 times higher than that of alum in the slow mixing period at $16^{\circ}C$ water temperature. Reasonable coagulant doses of alum and ferric chloride for turbidity removal were 0.1 mM (as Al) and 0.2 mM (as Fe), respectively, and the removal efficiency of those coagulant doses showed 94% for alum and 97% for ferric chloride. The appropriate coagulant dose of alum and ferric chloride for removing dissolved organic carbon (DOC) showed about 0.3 mM (as Al, Fe) and at this dosage, DOC removal efficiencies were 36% and 44%, and ferric chloride was superior to the alum for removal of the DOC in water.

Water Quality Control in the Semiclosed Culture System Growing a Flounder, Paralichthys Olivaceus (반폐쇄 순환여과식 넙치양식장의 수질제어에 관한 연구)

  • YANG Byung-Soo;LEE Heon-Mo;JEONG Byung-Gon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제25권3호
    • /
    • pp.197-204
    • /
    • 1992
  • A comparative evaluation of water quality in the existing semiclosed fish culture system was made to improve the system management. From the comparison of water quality between the flow-through mode and the recycle mode of the semiclosed system, the malfunctioning of the settling channel deteriorated water quality and reduce the nitrification rate in the recycle mode. The peak concentrations of COD, $PO_4-P$ and SS in the fish tanks appeared just after feeding, and then decreased to normal levels within two hours. However, the $NH_4-N$ concentration increased slightly after two hours of feeding in the recycle mode. The water exchange rate was directly related to the water quality in the semiclosed fish culture system.

  • PDF

Response Calibration for Bridges based on Statistical Quality Control Chart (통계적 품질 관리도에 기초한 교량의 응답 보정)

  • Hwang, Jin Ha;An, Seoung Su;Kim, Ju Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제33권1호
    • /
    • pp.61-70
    • /
    • 2013
  • This paper presents the response calibration method based on quality control range, which is established from the concept and method of statistical quality control for natural frequency ratio and response ratio. To this end, statistical analysis including descriptive statistics analysis, normality test, ANOVA were performed for response characteristics obtained from loading tests and structural analysis for more than hundred and thirty well-conditioned bridges. Suggested method is based on real structural integrity evaluation case studies and statistical quality control approach, in this respect it is expected to provide scientific criteria and systematic procedure for response calibration and load carrying capacity assessment.

PSE (pale, soft, exudative) Pork : The Causes and Solutions - Review -

  • Lee, Y.B.;Choi, Y.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권2호
    • /
    • pp.244-252
    • /
    • 1999
  • Intensive selection for muscle development and against fat deposition in pigs during the last 50 years has contributed to the increased incidence of porcine stress syndrome (PSS) and pale soft exudative pork (PSE). Genetics, nutrition and management, preslaughter animal handling, stunning, dehairing and carcass chilling influence the incidence and magnitude of the PSE condition. The normal incidence of PSE has been reported to range from 10 to 30%, but in some isolated instances is up to 60%. The elimination of halothane-positive pigs in breeding programs has reduced PSS and PSE. Further improvements in meat quality by terminal sire evaluation and selection can be achieved within halothane-negative populations because around 20% of the variation in meat color and water binding capacity seems to be genetically related. Pre-slaughter handling on the farm, during transit to the packing plant and at the packing plant can greatly influence the meat quality, contributing 10 to 25% of the variation. An effective stunning method, skinning instead of scalding/dehairing and rapid post-slaughter chilling further reduce the incidence of PSE pork. In addition to proper care and handling a carcass-merit based marketing system, that reflected the value differential between desirable and undesirable meat quality in the pricing system for pigs, would provide a great incentive to change pork production systems in order to improve meat quality, thus improving the image and usefulness of pork as food.

Effect of Harmonics and High-Frequency on OLEV System in Distribution Power System (온라인 전기자동차 시스템의 고조파 및 고주파가 배전계통에 미치는 영향에 관한 연구)

  • Choi, Seong-Ho;Huh, Jae-Sun;Han, Woon-Ki;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제63권6호
    • /
    • pp.738-745
    • /
    • 2014
  • Recently, various measures have been discussed for overcoming depletion of fossil fuels and environmental pollution. One of the measures is electric vehicles. But electric vehicles has some limitations from high cost of battery and low efficiency, so operation distance of electric cars is limited. Also there are difficulties that charging lines should be connected by an electric car whenever it charges. Thus, many studies have been conducted to overcome the limitation using conventional batteries of electric vehicles. As a result, the OLEV(On-Line Electric Vehicle) was developed. But the OLEV system is some limitations. The OLEV system causes power quality problems when it charges. Power quality problem cannot be ignored because OLEV systems are closely connected by distribution grids. In this paper, the OLEV system is designed by using PSCAD/EMTDC, and the power quality is measured and evaluated. Power quality is divided by two cases; harmonics and high-frequency. Harmonics were evaluated according to IEEE Std. 519-1992. But the evaluation of High-frequency could not take it because there was no standard. For this reason, the data measured by OLEV system was compared with the EN50065 regulation.

A Study on BASINS/WinHSPF for Evaluation of Non-point Source Reduction Efficiency in the Upstream of Nam-Han River Watershed (BASINS/WinHSPF를 이용한 남한강 상류 유역의 비점오염원 저감효율평가)

  • Yoon, Chun-Gyeong;Shin, Ah-Hyun;Jung, Kwang-Wook;Jang, Jae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • 제23권6호
    • /
    • pp.951-960
    • /
    • 2007
  • Window interface to Hydrological Simulation Program-FORTRAN (WinHSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Nam-Han river watershed to examine its applicability for loading estimates in watershed scale and to evaluate non-point source control scenarios using BMPRAC in WinHSPF. The WinHSPF model was calibrated and verified for water flow using Ministry of Construction and Transportation (MOCT, 3 stations, 2003~2005) and water qualities using Ministry of Environment (MOE, 5 station, 2000~2006). Water flow and water quality simulation results were also satisfactory over the total simulation period. But outliers were occurred in the time series data of TN and TP at some regions and periods. Therefore, it required more profit calibration process for more various parameters. As a result, all the study was performed within the expectation considering the complexity of the watershed, pollutant sources and land uses intermixed in the watershed. The estimated pollutant load for annual average about $BOD_5$, T-N and T-P respectively. Nonpoint source loading had a great portion of total pollutant loading, about 86.5~95.2%. In WinHSPF, BMPRAC was applied to evaluate non-point source control scenarios (constructed wetland, wet detention ponds and infiltration basins). All the scenarios showed efficiency of non-point source removal. Overall, the HSPF model is adequate for simulating watersheds characteristics, and its application is recommended for watershed management and evaluation of best management practices.

Physical Properties of Major Bedrocks in Chungju-Goesan Area as Aggregates (충주-괴산일대에서 산출되는 주요 기반암의 골재로서의 물성특징)

  • Byoung-Woon You;Jaehyung Yu
    • Economic and Environmental Geology
    • /
    • 제55권6호
    • /
    • pp.649-659
    • /
    • 2022
  • This study examined the granite, quartzite, phyllite, schist, and gneiss as aggregate resources among the original rock distributed in the Chungju-Goesan area. The granite distributed in the study area is mainly composed of Jurassic biotite granite, and the quartzite layer is from the Daehyangsan quartzite Formation distributed on the upper part of the Gyemyeongsan Formation and the Hyangsan-ri dolomitic limestone Formation. In addition, phyllite is pophyrytic phyllite-schist from the Hwanggangri Formation of the Okcheon group, schist is chlorite schist, from the Munjuri Formation of the Okcheon group, and gneiss is porphyroblastic gneiss which is the upper part of the Seochangri Formation. Aggregate quality evaluation factors of these rocks included fineness modulus, absorption, unit weight, absolute dry density, solid content, porosity, resistance to abrasion, and soundness. In the case of granite, it was found to be partially unsatisfactory in terms of unit weight, solid content, porosity, and resistance to abrasion. Gneiss was found to be out of the standard values in resistance to abrasion and schist in porosity and solid content. As for the overall quality of aggregate resources, it was analyzed that quartzite, gneiss, and phyllite showed excellent quality. Aggregate quality tests are performed simply for each rock, but the rock may vary depending on the morphology of the mineral. Therefore, when analyzing and utilizing the quality evaluation of aggregate resources, it will be possible to use them more efficiently if the rock-mineralological research is performed together.