  • The purpose of this articls is to investigate the impacts of ISO 14001 certification on the compliance of environmental regulations by Korean companies. The impact of ISO 14001 certification on the industries obtained the certificates was studied through a survey with questionnaires, and the compliance of environmental regulations was investigated using governmental release data. Motivations of Korean companies' environmental management were mostly caused by customer's request and the requirement from foreign countries. Certified enterprises showed more 3 times compliance of environmental regulation than non-certified ones. Such results were accomplished by systematic environmental management such as clear implementation purpose and all employee's voluntary improving according to ISO 14001 requirement. The continuous monitoring system was possible through internal audit and biannual audit from the certification body, to be finally verified by the top management. The four steps in ISO 14001 environmental management system, which are objective, methodology, inspection and monitoring, has contributed to this achievement.

  • PDF

Development and Performance Evaluation of Multiple Sensor for Groundwater Quality Monitoring and Remote Control System using IoT (IoT기반 지하수 수질모니터링을 위한 다중센서모듈 개발 및 성능평가)

  • Chang, Hyunjin;Moon, Boram;Yoon, Seunggyun;Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1957-1963
    • /
    • 2017
  • This paper has proposed a new-type groundwater auto-monitoring system based on Multi-Sensor Device. The system adopted Multi-Sensor Device as host computer of data acquisition, used Windows Mobile which was prevalent operation system of Multi-Sensor Device. It adopted serial port CAN and RS485 as the communication interface between goundwater sensor Device and monitor host machine and utilized serial-linked multi-sensor design to measure effectively according to the depth of groundwater. We present a design for a groundwater monitoring system based on a network of wirelessly linked sensors. The proposed solution will enable groundwater researchers and decision makers to have quick access to the groundwater data with less effort and cost. Though our design is initially meant for groundwater monitoring, it can be easily adapted to other fields of environmental monitoring.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

Basic Monitoring Concept for Revised Unit Load on NPS (비점오염원 원단위 개정을 위한 조사연구 방향)

  • Shin, Dongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.429-433
    • /
    • 2007
  • Many researchers have made a study of NPS unit-loads and the scientific evaluation method which need for formulating and enforcing a Total Maximum Daily Load (TMDL) management system and modifying a pollutant discharge loadings function. Some showed the event mean concentration (EMC) on single land-use. For the most parts, as the results showed on multiple land-uses, those cannot be used for NPS unit-loads calculation. NPS runoff shows various phenomena depending on rainfall monitoring data, therefore sampling methods and frequency for NPS monitoring must be different from the general monitoring for water quality trend assessment.

Recent Advances in Structural Health Monitoring

  • Feng, Maria Q.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.483-500
    • /
    • 2007
  • Emerging sensor-based structural health monitoring (SHM) technology can play an important role in inspecting and securing the safety of aging civil infrastructure, a worldwide problem. However, implementation of SHM in civil infrastructure faces a significant challenge due to the lack of suitable sensors and reliable methods for interpreting sensor data. This paper reviews recent efforts and advances made in addressing this challenge, with example sensor hardware and software developed in the author's research center. It is proposed to integrate real-time continuous monitoring using on structure sensors for global structural integrity evaluation with targeted NDE inspection for local damage assessment.

Development of an Architecture Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 건축물 모니터링 시스템 구현)

  • Chang, Hyung-Jun;Kim, Beom-Soo;Kong, Young-Bae;Park, Gwi-Tae;Shim, II-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.568-573
    • /
    • 2007
  • Environmental information (temperature, humidity, vibration, $CO_2$, gas leakage, etc.) of building is an essential item to manage and monitor a building. For intelligent building, it is necessary to get temperature and illumination information to save energy and crack information to prevent structural problems. Moreover, temperature and gas leakage information to alarm a tire precaution, or humidity information to maintain comfortable environment. However, there have not been many researches on systems for gathering environmental information and building maintenance due to high costs. In this paper, wireless sensor network technology is applied to collecting building environmental information. Wireless sensor network is one of the latest issues and has low-power consumption, low-cost, self-configuration features.

A Study on the Comparison of Emission Factor Method and CEMS (Continuous Emission Monitoring System) (배출계수법과 연속자동측정법에 의한 배출량 비교 연구)

  • Jang, Kee-Won;Lee, Ju-Hyoung;Jung, Sung-Woon;Kang, Kyoung-Hee;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.410-419
    • /
    • 2009
  • Generally, air pollutant emission at workplace is estimated by two methods: indirect methods using emission factors and direct methods based on CEMS (Continuous Emission Monitoring System). CAPSS (Clean Air Policy Support System) is a representative indirect method and the national air pollutant database of Korea. However, characteristics of some workplaces may create a gap between CAPSS and CEMS data. For improving of emission data accuracy, emission data of CEMS (named CleanSYS) equipped at 138 target workplaces were compared with those of CAPSS. As a result, $SO_x$ and $PM_{10}$ emission levels obtained by CAPSS were lower than those of CleanSYS. $SO_x$ and $PM_{10}$emission ratios were 61.5% and 71.2% lower respectively, showing the biggest gaps. On the other hand, $NO_x$ emission of CAPSS was higher by 10.4%. $SO_x$ showed the biggest difference in 'Energy industry combustion' and $NO_x$ did in 'Production Process' within the SCC category. $PM_{10}$ presented a large gap in 'Manufacturing industry combustion.' The differences in $SO_x$ between the two systems occurred because some large-size facilities lack pollution controllers or efficient pollution controllers. Based on this study, CAPSS emission database of Korea will improve accuracy through adopting CEMS emission system, which enables more efficient national atmospheric policies and workplace management.

Development of Long Term Flow Duration Curves in 4 River Basins for the Management of Total Maximum Daily Loads (수질오염총량관리를 위한 4대강수계 장기유황곡선 작성방안)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.343-353
    • /
    • 2013
  • Flow duration curve (FDC) can be developed by linking the daily flow data of stream flow monitoring network to 8-day interval flow data of the unit watersheds for the management of Total Maximum Daily Loads. This study investigated the applicable method for the development of long term FDC with the selection of the stream flow reference sites, and suggested the development of the FDC in 4 river basins. Out of 142 unit watersheds in 4 river basins, 107 unit watersheds were shown to estimate daily flow data for the unit watersheds from 2006 to 2010. Short term FDC could be developed in 64 unit watersheds (45%) and long term FDC in 43 unit watersheds (30%), while other 35 unit watersheds (25%) were revealed to have difficulties in the development of FDC itself. Limits in the development of the long term FDC includes no stream monitoring sites in certain unit watersheds, short duration of stream flow data set and missing data by abnormal water level measurements on the stream flow monitoring sites. To improve these limits, it is necessary to install new monitoring sites in the required areas, to keep up continuous monitoring and make normal water level observations on the stream flow monitoring sites, and to build up a special management system to enhance data reliability. The development of long term FDC for the unit watersheds can be established appropriately with the normal and durable measurement on the selected reference sites in the stream flow monitoring network.

The Study on the Analysis of Stormwater Runoff Using RMS (Remote Monitoring System) (원격수위계측기를 이용한 강우유출 분석에 관한 연구)

  • Ham, Kwang-Jun;Kim, Joon-Hyun;Yi, Geon-Ho;Choi, Ji-Yong;Jeong, Ui-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.6
    • /
    • pp.285-294
    • /
    • 2004
  • The purpose of this study is to understand the quantitative change of water resources using RMS(Remote Monitoring System) which takes real time data with high reliability. Also, the characteristic of stormwater runoff was understood by the application of the above system for three streams (Jiam, Yulmun, and Gongji stream) in Chuncheon City. The detailed results of these studies are as follows; RMS(Remote Monitoring System) was constructed by the combination of the automatic water-level meter, which measures water-level of streams at all times, and the wireless communication system sending real-time data from the meter. This system is used to evaluate the stormwater runoff in watersheds and the quantitative changes of streams. It is possible to overcome the limit of field investigations needed, which takes a lot of manpower and time, and it is very efficient to provide the reliable flowrate data. Also, it can be applied to the disaster prevention system for flood because the change of flowrate in stream is monitored at real-time. For 3 streams with different watershed characteristics, correlation equations induced from the relation analysis results. In terms of the relation between water-level and flowrate, flowrate was increased rapidly as the water-level rises in case of small watershed and steep slope. The application results of the proposed system for 3 streams (Jiam, Yulmun, Gongji) in Chuncheon city are as follows; The remote monitoring system was very useful for acquisition of the flow rate in stream that are basic data to understand pollutants runoff in watershed. In case of no-rainy day, the runoff ratio for pollutant loading rate was the highest level in Yulmun stream(BOD:2.3%, TN:20.2%, TP:1.2%). So, it shows the management of pollution source is needed such as rehabilitation of sewer line. Runoff ratio of total phosphorus by rainfall in Gongji watershed was increased about 19 times than no-rainy day, which is estimated as the influence of sewer overflow.

Fault diagnosis of walking beam roller bearing by FTA (FTA(Fault Tree Analysis)기법을 이용한 이송용 대부하 베어링 고장 진단)

  • Bae, Y.H.;Lee, H.K.;Lee, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.110-123
    • /
    • 1994
  • The development of automatic production systems have required inteligent diagnostic and monitoring function to repair system failure and reduce production loss by the failure. In order to perform accurate functions of intelligent system, inferencing about total system failure and fault analysis due to each mechanical component failures are required. Also the solution about repair and maintenance can be suggested from these analysis results. As an essential component of mechanical system, a bearing system is investigated to define the failure behavior. The bearing failure is caused by lubricant system failure, metallurgical defficiency, mechanical condition(vibration, overloading, misalignment) and environmental effect. This study described roller bearing fault train due to stress variation and metallurgical defficiency from lubricant failure by using FTA.