• 제목/요약/키워드: Environmental Attenuation

검색결과 263건 처리시간 0.023초

Analysis of Traffic Noise Propagation around Main Roads in Kwang-ju City

  • Choi, Hyung-II;Cheong, Kyung-Hoon
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권1호
    • /
    • pp.1-9
    • /
    • 2000
  • This paper describes an analysis of various factors affecting traffic noise propagation, including the distance from the road, existence of a direct path of noise propagation, density and height of buildings, and procedure for predicting the attenuation of noise levels from roads. The analysis is based on a multiple number of regression models, utilizing the quantification theory of the first kind. This study incorporates a large amount of survey data concerning traffic noise propagation. The survey of the traffic noise propagation around main roads was carried out in several residential areas, mainly in Kwangju. The attenuation of noise levels measured provided 691 usable data samples. A multiple regression analysis demonstrated that the distance from the road makes the most significant contribution to the attenuation of the noise level. The second contributor was found to be the existence of a direct path of noise propagation. The building density and average height of the buildings also affected the attenuation of the noise level considerably. Other factors, such as the height of the building behind the receiver microphone and the number of traffic lanes on the noise-source roads, did not contribute as much to the attenuation of the noise level as the factors mentioned avove.

  • PDF

비교 측정을 통한 PM-10 질량농도의 오차 분석 (Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study)

  • 정창훈;조용성;황승만;정용국;유재천;신동석
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

환경감쇠인자를 고려한 레이더 탐지 확률 변화에 관한 연구 (Study on the Radar Detection Probability Change Considering Environmental Attenuation Factor)

  • 김영웅;박상철
    • 한국시뮬레이션학회논문지
    • /
    • 제24권4호
    • /
    • pp.23-28
    • /
    • 2015
  • 탐지 분야는 전장에 영향을 미치는 요인들 중 중요한 부분이다. 기본적으로 레이더는 정해진 방향으로 탐지를 수행하기 위해 전파를 방출한다. 그러나 기존의 레이더들 대부분이 돌아온 전파를 이용해 신호처리 과정에 의해 표적을 확인할 때, 환경 감쇠 요소는 반영되지 않는다. 이러한 전자파를 이용하는 레이더는 환경적 조건에 의한 감쇠요인에 따라 탐지 결과가 달라질 수 있는 가능성을 가지고 있어, 실제 전장에서 작전상 문제가 발생할 수도 있다. 그렇기 때문에, 이 논문에서는 전파가 돌아올때, 기존의 레이더 방정식에 환경 감쇠 요인을 반영하여 더 정확한 표적을 확인하기 위한 시도를 해보고자 한다.

확률적 정량모델을 이용한 토양에서의 바이러스 저감 평가 (Assessment of Viral Attenuation in Soil Using Probabilistic Quantitative Model)

  • 박정안;김재현;이인;김성배
    • 대한환경공학회지
    • /
    • 제33권7호
    • /
    • pp.544-551
    • /
    • 2011
  • 본 연구의 목적은 미국 환경보호청에서 개발한 확률적 정량모델인 VIRULO 모델의 구성과 특성을 분석하는 것이다. 이 모델은 몬테카를로 방법을 이용하여 수리지질학적 차단벽으로써 토양의 바이러스 저감능을 평가할 수 있는 모델이다. 모델에 사용된 지배방정식은 크게 불포화 지역에서의 물의 흐름식과 바이러스의 이동식으로 구성되어 있다. 사용되는 파라미터들 중, 물의 흐름과 관련된 파라미터는 11종류의 토양에 대하여 UNSODA 데이터베이스로부터 얻어진 것 들이며, 바이러스와 관련된 파라미터 값들은 다섯 종류의 바이러스에 대하여 문헌조사를 통해 정리된 것이다. 모델은 목표로 하는 바이러스 저감 역치값과 특정 조건에서 몬테카를로 모사를 통해 얻어진 토양의 바이러스 저감인자를 비교하여, 목표로 하는 바이러스 저감 역치값에 도달하지 못하는 확률을 결정한다. 그리고, 몬테카를로 모사횟수와 목표 역치값에 도달하지 못한 횟수를 결과물로 제시한다. 11개의 USDA 토양을 대상으로 바이러스 저감을 평가한 결과, 양질사토와 모래의 바이러스 저감능이 점토나 미사 계열의 토양에 비하여 상당히 떨어지는 것으로 평가되었다. 5종의 바이러스를 대상으로 저감을 비교한 결과, 바이러스 간에 저감 정도에 차이가 있는 것으로 나타났으며, 그 중 폴리오바이러스의 저감 정도가 가장 큰 것으로 분석되었다. 그리고, 토양 함수량이 증가함에 따라 토양의 바이러스 저감능이 급격하게 감소하였으며, 토양의 깊이가 증가함에 따라 바이러스 저감능이 비선형적으로 증가하였다. 본 연구에 의하면, VIRULO 모델은 지중환경에서의 바이러스 위해성 평가에 사용될 수 있는 유용한 스크리닝 도구로 판단된다.

철도교통소음의 특성에 관한연구 (A Study on the Characteristics of Railroad Traffic Noise)

  • 최형일;박상일;염동익
    • 한국환경과학회지
    • /
    • 제16권7호
    • /
    • pp.771-778
    • /
    • 2007
  • This study has been conducted to achieve the following objectives: First, in order to understand the horizontal propagation and attenuation characteristics for the railroad traffic noise, we selected areas within 100 meters away from the railroad and then selected Saemaul-ho and Mugoongwha-ho as the subjects for our experiment. In this way, we analyzed the horizontal propagation and attenuation characteristics for the traffic noise occurring in diversified areas. Second, in order to understand the vertical propagation and attenuation characteristics for the railroad traffic noise, we measured and analyzed the distributional characteristics of vertical sound pressure levels on each floor of multi-storied apartment buildings according to changes of traffic load and types, and the existence or nonexistence of soundproof walls. For the case of the railroad traffic noise, we also selected Samaul-ho and Mugoongwha-ho as the subjects for our experiment, and we measured and analyzed the different noise levels on each floor of multi-storied apartment buildings from the soundproof wall. The results of Horizontal propagation and attenuation characteristics for the railroad traffic noise are as follows: In cases of the flat land, cutting land, and bridge area, as distance increases, the sound pressure level steadily decreases. The sound pressure level for the bridge area is higher than that of the flat land with a measurement of $5.5{\sim}10.2\;dB(A)$. Vertical propagation and attenuation characteristics for the railroad traffic noise are as follows: The amount of sound pressure level decrease is $14.2{\sim}14.8\;dB(A)$ for Samaul-ho and $13.5{\sim}14.3\;dB(A)$ for Mugoongwha-ho when measuring the vertical sound pressure levels at heights lower than 4.5 m, which indicates a fairly large decrease. At 6 m, the amount of decrease is 8.6 dB(A) for Samaul-ho and 8.2 dB(A) for Mugoongwha-ho, which indicates a small decrease.

다성분 반응 이동 모델링을 이용한 트리클로로에틸렌(TCE)으로 오염된 지하수에서의 자연저감 평가 (Assessment of Natural Attenuation Processes in the Groundwater Contaminated with Trichloroethylene (TCE) Using Multi-Species Reactive Transport Modeling)

  • 진성욱;전성천;김락현;황현태
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.101-113
    • /
    • 2016
  • To properly manage and remediate groundwater contaminated with chlorinated hydrocarbons such as trichloroethylene (TCE), it is necessary to assess natural attenuation processes of contaminants in the aquifer along with investigation of contamination history and aquifer characterization. This study evaluated natural attenuation processes of TCE at an industrial site in Korea by delineating hydrogeochemical characteristics along the flow path of contaminated groundwater, by calculating reaction rate constants for TCE and its degradation products, and by using geochemical and reactive transport modeling. The monitoring data showed that TCE tended to be transformed to cis-1,2-dichloroethene (cis-1,2-DCE) and further to vinyl chloride (VC) via microbial reductive dechlorination, although the degree was not too significant. According to our modeling results, the temporal and spatial distribution of the TCE plume suggested the dominant role of biodegradation in attenuation processes. This study can provide a useful method for assessing natural attenuation processes in the aquifer contaminated with chlorinated hydrocarbons and can be applied to other sites with similar hydrological, microbiological, and geochemical settings.

Beta particle energy spectra shift due to self-attenuation effects in environmental sources

  • Alton, Thomas Theakston;Monk, Stephen David;Cheneler, David
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1483-1488
    • /
    • 2017
  • In order to predict and control the environmental and health impacts of ionizing radiation in environmental sources such as groundwater, it is necessary to identify the radionuclides present. Beta-emitting radionuclides are frequently identified by measuring their characteristic energy spectra. The present work shows that self-attenuation effects from volume sources result in a geometry-dependent shift in the characteristic spectra, which needs to be taken into account in order to correctly identify the radionuclides present. These effects are shown to be compounded due to the subsequent shift in the photon spectra produced by the detector, in this case an inorganic solid scintillator ($CaF_2:Eu$) monitored using a silicon photomultiplier. Using tritiated water as an environmentally relevant, and notoriously difficult to monitor case study, analytical predictions for the shift in the energy spectra as a function of depth of source have been derived. These predictions have been validated using Geant4 simulations and experimental results measured using bespoke instrumentation.

An Analysis of Attenuation Effect of Pressure Head Using an Air Chamber

  • Lee, Jae-Soo;Yoon, Yong-Nam;Kim, Joong-Hoon
    • Korean Journal of Hydrosciences
    • /
    • 제7권
    • /
    • pp.77-86
    • /
    • 1996
  • An air chamber is design to keep the pressure from exceeding a predetermined value, or to prevent low pressures and colum separation. Therefore, it can be used to protect against rapid transients in a pipe system following abrupt pump stoppage. In this research, an air chmber was applied to a hypthetical pipe system to analyze attenuation effect of pressure head for different air volumes, locations, chamber areas, coefficients of orifice loss and pollytropic exponents. With an increase of air volume, the maximum pressure head at pump site is decreased and the minimum pressure head is imcreased. For different locations and areas of the chamber, the attenuation effects do not show much difference. Also, as the orifice loss coefficient increases, the maximum pressure head is decreased. For different polytropic exponents, isothermal process shows lower maximum pressure head than that of the adiabatic process.

  • PDF

주변 흙의 특성이 물이 찬 매립된 배관에서 전파되는 기본 유도 종파 모드 감쇠에 미치는 영향 (Effect of Surrounding Soil Properties on the Attenuation of the First Guided Longitudinal Wave Mode Propagating in Water-filled, Buried Pipes)

  • 이주원;나원배;신성우;김재민
    • 한국해양공학회지
    • /
    • 제24권4호
    • /
    • pp.32-37
    • /
    • 2010
  • This study presents the attenuation characteristics of the first guided longitudinal wave mode propagating in water-filled, buried steel pipes in order to investigate the effects of soil saturation and compaction on the attenuation patterns. For numerical calculation of attenuation, 10 different combinations of S-wave velocity, P-wave velocity, and soil densities were considered. From the attenuation dispersion curves, which were obtained using Disperse software, we determined that the attenuation decreases as saturation increases, whereas it increases as compaction increases. Over the frequency range from 0.2 to 0.4 MHz, the first longitudinal wave mode has attenuations that are relatively lower than for other ranges, is faster than the first flexural wave mode, and is sensitive to defects aligned in the axial direction. Hence, the first longitudinal wave mode over the mentioned frequency range would be the proper choice for long-range buried pipelines that transport water.