• 제목/요약/키워드: Environment Vibration

검색결과 1,153건 처리시간 0.029초

전력용변압기의 구조진동해석 및 능동소음제어 (Structure Vibration Analysis and Active Noise Control of Power Transformer)

  • 정윤미;최은지;김영달
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1771-1776
    • /
    • 2013
  • Most cases of power transformer failure are caused by physical factors linked to the transient vibrations of multiple 120Hz combinations. In addition, the noise generated in the transformer from this vibration not only directly contributes to the worsening of the work environment but also causes psychological stress, resulting in the worsening of the workers efficiency and of the living environment of the inhabitants around the power plant. Thus, to remedy these problems, the mechanical-excitation forces working on a power transformer were categorized in this study, and the mechanical-damage mechanism was identified through the vibration transfer paths acting on machines or structures. In addition, a study on active noise cancellation in a transformer using the FXLMS algorithm was conducted to develop a system that is capable of multiple-sound/channel control, which resulted in the active noise reduction effect when applied on the field.

금속가공 작업자의 국소진동 평가 (Evaluation of Hand- Arm Vibration of Steel Processing Factory Workers)

  • 연정택;박상규;김소연;이태영;장재연
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.52-65
    • /
    • 1999
  • This study was performed to evaluate the hand-arm vibration of the steel processing factory workers. Measurement, evaluation and as sessment were based on the International Standard(ISO 5349). The frequency weighted accelerations of the various hand-held tools and total exposure time were measured to assess the periods for the white finger symptom to occur. As a result, it was found that the air angle grinder and the air baby grinder are more harmful than other hand-held tools. It was also found that using various vibratory tools together is more harmful than using a single tool.

  • PDF

진동모터로 구성된 햅틱 디바이스를 이용한 장애물 정보 전달 및 제어 방법 (Obstacle Information Transfer and Control Method using Haptic Device consist of Vibration Motors)

  • 이동혁;노경욱;강선균;한종호;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제20권10호
    • /
    • pp.1036-1043
    • /
    • 2014
  • In this paper, a new haptic device is proposed for the teleoperation, which can recognize the invisible environment of a mobile robot. With this new device, it is possible for the user to identify the location of an obstacle and to avoid it. The haptic device has been attached on the top of a joystick so that the user can remotely control the mobile robot to avoid the obstacles which are recognized by the ultrasonic sensors. Also, the invisible environment is recognized more accurately overlapping the data from the ultrasonic sensors. There are five vibration motors in the haptic device to indicate the direction of the obstacle. So the direction of the obstacle can be recognized by the vibration at the finger on each vibration motor. For various situations and surrounding environments, experiments are performed using fuzzy controller and overlapping ultrasonic sensors. The results demonstrate the effectiveness of the proposed haptic joystick.

공조기가 설치된 고분 내에서의 열 및 음 환경 평가 (Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System)

  • 박진양;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

항공기 실측 진동 데이터를 이용한 환경시험 규격 생성 연구 (Development of Environmental Test Specifications for Aircraft Using Measured Vibration Data)

  • 김충현;송기혁
    • 한국군사과학기술학회지
    • /
    • 제24권3호
    • /
    • pp.302-308
    • /
    • 2021
  • Developers generally use test standards suggested by military standards such as MIL-STD-810G when performing vibration tests in the materiel development. However, according to MIL-STD-810G, it is recommended to test by tailoring the test standard suitable for the developed materiel, and it is specified to apply the suggested test standard only when there is difficulty in tailoring. In addition, the test standards presented by MIL-STD-810G are standards created under operating conditions different from the actual operating environment of each developed materiel, so the test according to this standard may be excessive or understated. Therefore, the developer must create an appropriate vibration test standard for the developed materiel as similar to the operating conditions as possible. In this paper, the procedure for creating the functional test standard and durability test standard suitable for the operating environment of the equipment to be mounted on the propeller aircraft under development is described, and the created standard is introduced.

Vibration characteristics of functionally graded carbon nanotube-reinforced composite double-beams in thermal environments

  • Zhao, Jing-Lei;Chen, Xu;She, Gui-Lin;Jing, Yan;Bai, Ru-Qing;Yi, Jin;Pu, Hua-Yan;Luo, Jun
    • Steel and Composite Structures
    • /
    • 제43권6호
    • /
    • pp.797-808
    • /
    • 2022
  • This paper presents an investigation on the free vibration characteristics of functionally graded nanocomposite double-beams reinforced by single-walled carbon nanotubes (SWCNTs). The double-beams coupled by an interlayer spring, resting on the elastic foundation with a linear layer and shear layer, and is simply supported in thermal environments. The SWCNTs gradient distributed in the thickness direction of the beam forms different reinforcement patterns. The materials properties of the functionally graded carbon nanotube-reinforced composites (FG-CNTRC) are estimated by rule of mixture. The first order shear deformation theory and Euler-Lagrange variational principle are employed to derive the motion equations incorporating the thermal effects. The vibration characteristics under several patterns of reinforcement are presented and discussed. We conducted a series of studies aimed at revealing the effects of the spring stiffness, environment temperature, thickness ratios and carbon nanotube volume fraction on the nature frequency.

건설 소음.진동의 사전 영향성 분석에 관한 연구 (Study on Preliminary Influence Analysis of Construction Noise and Vibration)

  • 안명석;김화일;박주한
    • 화약ㆍ발파
    • /
    • 제32권2호
    • /
    • pp.25-30
    • /
    • 2014
  • 건설공사 현장에서 발생하는 소음 진동은 일시적이고 간헐적으로 발생하지만 그 영향은 매우 크다. 건설기계의 적은 소음 진동이라도 발생하면 먼 거리까지 전달되어 차음 및 방진 등의 대책이 어려워 이를 해결하기 위해 본 연구에서는 건설장비의 소음 진동 안전기준을 30m로 적용하였고 발파소음은 60m, 진동은 160m로 적용하였다. 지금까지는 2D를 사용한 모델링을 주로 사용하였으나 건물이나 산과 언덕 등 크기와 높이를 고려한 3차원 3D 모델링으로 측정 분석하여서 정확도를 높였다.

Research on the Model, Structure and Characteristics of a New Vibration Generator

  • Zhang, Qing-Xin;Yu, Li;Lin, Tong;Gao, Yun-Hong;Wang, Lu-Ping
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권6호
    • /
    • pp.335-340
    • /
    • 2016
  • The vibrational energy is prevalent in the natural environment, which is studied by energy researchers as a new energy resource in recent years. Vibration generation utilizes electromagnetic induction technology, piezoelectric technology and certain characteristics of smart materials to convert mechanical energy into electrical energy. In this paper, a new method of using MSMA (magnetic shape memory alloy) to generate electricity is proposed and the principle of generating electricity is demonstrated. Martensitic variants and magnetic domain characteristics of MSMA are analyzed. Combining with Gibbs free energy function thermal theory, the mathematics model of MSMA vibration generator is established. The basic structure of MSMA vibration generator is designed and simulation is done to analyze that the effects of generator output voltage when the input amplitude and frequency of vibration stress change. The simulation experiments verify the feasibility of using MSMA to make the micro vibration generators and the correctness of the mathematical model, which lays a good foundation for the further research and application of MSMA vibration generator.

Sensitivity Analysis of Anti-resonance Frequency for Vibration Test Control of a Fixture

  • Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Jun-Yeop
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1732-1738
    • /
    • 2003
  • The test specimen in environmental vibration test is connected to the fixture through several attachment points. The forces generated by the shaker must be transmitted equally to all attachment points. The forces transmitted to attachment points, however, are different because of the flexural vibration of the fixture. The variations of the transmitted force cause the under-test, especially at anti-resonance frequencies, in vibration test control. Anti-resonance frequencies at the attachment points of the fixture must be same in order to avoid the under-test in vibration test control. The structural modification of the fixture is needed so that anti-resonance frequencies at attachment points have the same value. In this paper, the method to calculate the anti-resonance frequencies and those sensitivities is presented. This sensitivity analysis is applied to the structural modification of the fixture excited at multi-points by the shaker. The antiresonance frequencies at the attachment points of the fixture can have the same value after structural modification, and the under-test in the vibration test control can be removed. Several computer simulations show that the proposed method can remove the under-tests, which are not removed in conventional vibration test control.

지하철 운행에 따른 진동특성에 관한 연구 (A Study on the Characteristics of Vibration Induced by Subway Operation)

  • 배동명;신창혁;최철은;박상곤;백용진
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.249-256
    • /
    • 2001
  • In this paper the characteristics of vibration induced by subway trains running on track is discussed. The quantitative prediction of the vibration level and the countermeasure for reduction of necessary, is of importance for the better environment. It was made the constructed Bundang line as first step with the modified Young-Dan type to basis on the Japanese Young-Dan type. In this paper it was measured and analyzed to two region ($ \circled1$Susuh-Bokjung. $ \circled2$Chorim-Suhyun region) of this. at present, operational Bundang line when averaging velocity of train is 60 (km/h). As the response characteristics of frequency Induced by subway operation, it was confirmed that frequency band of neighborhood of 30~80 Hz in generally dominant. Also to assess the quantitative nitration as response level to be measured for each point of two region in subway operation, the vibrational response level was measured at the state to be not subway operation. And the level was approximately $\fraction one-fifth~\fraction one-ten$ level comparing to subway operation.

  • PDF