• Title/Summary/Keyword: Environment Tests

Search Result 2,685, Processing Time 0.032 seconds

Ergonomic Design of Medic Work Table (MWT) for Medical Technologist

  • Choi, Kyeong-Hee;Lee, Sung-Yong;Lee, Jun-Hyub;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.595-609
    • /
    • 2016
  • Objective: The purpose of this study was to develop and validate the guidelines for Medic Work Table (MWT) based on the anthropometric data of medical technologists. Background: Users' anthropometric data such as sitting height, sitting elbow height, knee height, and so on are significant factors for designing comfortable and useful furniture. Thus, many guidelines for different types of desks and chairs based on the users' anthropometric data have been suggested to many researchers. However, few researches have been conducted to provide design guidelines for MWT for blood collecting task. Medical technologists often use their upper extremities to perform blood collecting task with high repetitions. These repeated motions could be a critical factor in the prevalence rate of Work-related Musculoskeletal Disorders (WMSDs). Therefore, a study on ergonomic design of MWT would be essential in preventing the WMSDs and improving the quality of the working environment of medical technologists. Method: This study suggested design guidelines for ergonomic MWT by focusing on the heights of the upper side and underside, depths of the inside and outside, and width of MWT through anthropometric studies and literature reviews. Afterwards, a new MWT was made using the suggested design guidelines for this study. Five healthy medical technologists participated to evaluate the original MWT and new MWT. All participants took part in the range of motion (ROM) test, electromyography (EMG) muscle activity test, and usability test to validate the suggested guidelines in this study. EMG signals of related muscles (Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Deltoid Anterior, and Biceps Branchii) were recorded through the surface electromyography system from both the original MWT and the new MWT. The ROM test of the shoulder and elbow flexion was also assessed using motion sensors. Results: The newly designed MWT showed decreased ROMs of the shoulder and elbow up to 22% and 18% compared to the original MWT. The muscle activities in the new MWT also showed a decrease of 13% in Anterior Deltoid, 6% in Biceps Brachii, 5% in Flexor Carpi Ulnaris, and 8% in Extensor Carpi Ulnaris muscle groups, compared to the original MWT. In the usability test, the satisfaction score of the new MWT was also 56.1% higher than that of the original MWT. Conclusion: This study suggested guidelines for designing MWT and validating the guidelines through qualitative and quantitative analyses. The results of motion analysis, muscle activity, and usability tests demonstrated that the newly designed MWT may lead to less physical stress, less awkward posture, and better physical user interface. Application: The recommended guidelines of the MWT would be helpful information for designing an ergonomic MWT that reduces physical loads and improves the performance of many medical technologists.

Influence of Polarization Behaviors on the ECM Characteristics of SnPb Solder Alloys in PCB (PCB에서의 ECM 특성에 미치는 SnPb 솔더 합금의 분극거동의 영향)

  • Lee Shin-Bok;Yoo Young-Ran;Jung Ja-Young;Park Young-Bae;Kim Young-Sik;Joo Young-Chang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.2 s.35
    • /
    • pp.167-174
    • /
    • 2005
  • Smaller size and higher integration of electronic components make smaller gap between metal conducting layers in electronic package. Under harsh environmental conditions (high temperature/humidity), electronic component respond to applied voltages by electrochemically ionization of metal and metal filament formation, which lead to short failure and this phenomenon is termed electrochemical migration(ECM). In this work, printed circuit board(PCB) is used for determination of ECM characteristics. Copper leads of PCB are soldered by eutectic solder alloys. Insulation breakdown time is measured at $85^{\circ}C,\;85{\%}RH$. CAF is the main mechanism of ECM at PCB. Pb is more susceptible to CAF rather than Sn, which corresponds well to the corrosion resistance of solder materials in aqueous environment. Polarization tests in chloride or chloride-free solutions fur pure metal and eutectic solder alloys are performed to understand ECM characteristics. Lifetime results show well defined log-normal distribution which resulted in biased voltage factor(n=2) by voltage scaling. Details on migration mechanism and lifetime statistics will be presented and discussed.

  • PDF

Serotypes and genotypes of Salmonella isolates from slaughtered pigs (도축돈에서 분리된 살모넬라의 혈청형 및 유전형)

  • Choi, Won-Zong;Jung, Ji-Hun;Won, Ho-Keun;Kang, Zheng-Wu;Hahn, Tae-Wook
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.1
    • /
    • pp.1-16
    • /
    • 2008
  • Salmonella infections cause the disease in pigs but also some zoonotic Salmonella serotypes can be transmitted to human through swine products, resulting in food poisoning. The objective of this study was to investigate the bacteriological prevalence and detection of invA gene using Salmonella specific polymerase chain reaction (PCR), the epidemiological characteristics related to Salmonella strains cultured from pig samples in Gangwon areas using serotyping, random amplified polymorphic DNA (RAPD) and pulsed field gel electrophoresis (PFGE) methods. During the period of November 2001 through April 2002, 1,174 ileocecal lymph node were collected from the slaughtered pigs raised in 38 farms located in Gangwon province. The samples were submerged in boiling water and macerated in saline and lymph node homogenates were inoculated into Tetrathionate broth with iodine (TTB, Difco, 0.5% iodine was added) for enrichment growth. Then additional tests were performed using several mediums, and suspects were identified by API 20E kit (BioMerieux) and PCR. Of total 1,174 samples from 38 farms, 44 (3.7%) were isolated as Salmonella spp from 13 farms (34.2%). Of 44 isolates, 31 were in Yangyang region, followed by 9 in Goseong, 2 in both Gangneung and Sokcho. However, there was no difference in regional isolation frequency. All isolates have a 521bp amplified product in Salmonella specific PCR with primer invA which encodes in proteins for invasion of epithelial cells. Of 44 recovered serotypes, 23 (52.3%) were S Eingedi, 10 (22.7%) S Schwarzengrund, 9 (20.5%) S Typhimurium, and 2 (4.5%) S Mbandaka. In RAPD analysis, there appeared to be unique bands distinguishing each serotype, although similarities exist between the different serotypes. Four serotypes of 44 Salmonella isolates appeared to fall into 14 different RAPD types. In PFGE analysis, 9 S Typhimurium were tested with XbaI enzyme and SpeI enzyme. The combination of results obtained with two enzymes subdivided the 9 S Typhimurium into 4 PFGE types.

A 30 GHz Band Low Noise for Satellite Communications Payload using MMIC Circuits (MMIC 회로를 이용한 위성중계기용 30GHz대 저잡음증폭기 모듈 개발)

  • 염인복;김정환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.796-805
    • /
    • 2000
  • A 30GHz band low noise amplifier module, which has linear gain of 30dB and noise figure of 2.6dB, for 30GHz satellite communication transponder was developed by use of MMIC and thin film MIC technologies. Two kinds of MMIC circuits were used for the low noise amplifier module, the first one is ultra low noise MMIC circuit and the other is wideband and high gain MMIC circuit. The pHEMT technology with 0.15$mu extrm{m}$ of gate length was applied for MMIC fabrication. Thin film microstrip lines on alumina substrate were used to interconnect two MMIC chips, and the thick film bias circuit board were developed to provide the stabilized DC bias. The input interface of the low noise amplifier module was designed with waveguide type to receive the signal from antenna directly, and the output port was adopted with K-type coaxial connector for interface with the frequency converter module behind the low noise amplifier module. Space qualified manufacturing processes were applied to manufacture and assemble the low noise amplifier module, and space qualification level of environment tests including thermal and vibration test were performed for it. The developed low noise amplifier was measured to show 30dB of minimum gain, $\pm$0.3dB of gain flatness, and 2.6dB of maximum noise figure over the desired operating frequency range from 30 to 31 GHz.

  • PDF

The Treatment of Volatile Organic Compounds Using a Pilot-Scale Biofilter (Pilot 규모의 바이오필터를 이용한 휘발성유기화합물질 제거)

  • Son, Hyun-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.245-252
    • /
    • 2004
  • Two biofilter tests were conducted under different operating conditions. Test # 1 was performed to treat VOCs generated from a paint booth. The second test was performed to treat VOCs generated from chemical manufacturing processes. The volume of biofilter media was 4.3 $m^3$. For the test # 1, the biofilter was operated for 30 days with 99.9% reduction ratio. Range of temperature of each stage of the biofilter media was measured between $34^{\circ}C$ and $73^{\circ}C$. All the temperatures of stages reduced gradually after the initial dramatic increase. For the test # 2, the biofilter experiment was conducted for 14 days. In this case, the biofilter was installed outdoor and the experiment was performed during wintertime. Therefore, temperature management for the biofilter was needed. Seven-centimeter thick fiberglass insulation and $150^{\circ}C$ steam heating were used to overcome the outside freezing cold weather during test # 2. Temperature of stage # 5 was measured the highest and that of stage # 1 was the lowest. More acclimation time and test period was needed to determine the maximum loading rate.

A Study of the Anxiety Levels of Hospitalized Psychiatric Patients in Terms of Length of Hospitalization (정신과 입원환자의 입원기간에 따른 불안정도에 관한 연구)

  • 김윤희
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.1
    • /
    • pp.45-63
    • /
    • 1981
  • This study was done to determine the relationship between the anxiety levels of hospitalized psychiatric patients and various influencing variables. The purpose of this study was to determine factors that may help hospitalized psychiatric patients to experience lower levels of anxiety in relation to changing situations and provide the basic data for a dynamic approach which is important in the field of modern psychiatric nursing that understands and analyses the meaning of patients behavior. The anxiety may produce stress, which is a common experience among all human beings. Patients may merely feel uncomfortable in the state of mild anxiety, however, the severe state could be an obstacle to treatment and recovery from disease. The anxiety of the psychiatric patient is a factor which greatly influencing the patient's behavior, so his disorderd behavior is an expression of defence or pathologically fixed behavior. According the psychiatric patient's anxiety at the time of admission is the concern of the health team. The nurse's special concern has to do with understanding and supporting the patient and meeting his individual needs by frequent close contact during the entire hospitalization period, compared to other teamembers the nurse's responsibility in this regard is greated. So this study emphasizes the necessity of creating conditions these, but above all the psychiatric nurse should create a therapeutic environment by not only regarding the patient's behavior or symptoms but understanding the meaning of them. The subjects of this study were 57 psychiatric patients selected from the K neuropsychiatric hospital located in Kunsan city. Data were collected twice from the same patients within a 24 hour period after admission and 10 days after admission. (September 18th to November 8th, 1980). The data collected method was through direct interview, and the interview time was 20 minutes for each patient. Data analysis included Item Analysis & Internal Consistency Reliability Tests, Percentages, t-test, analysis of variance and stepwise multiple regression analysis. The findings of this study were as follows. A. Test of Hypothesis a. Hypothesis 1 :“The anxiety level of psychiatric patients within 24 hours after admission will be higher than those of the same patients 10 days after admission,”was accepted. (t = 3. 15 ; p < 0.005) b. Hypothesi 2:“The more the number of admissions the higher the level of anxiety related to two categories”, was accepted. (affective anxiety: F = 5.50, p < 0.005, Somatic anxiety: F = 9.12, p <.

  • PDF

Evaluations on the Compaction Energy Effects on the Soil Compaction at Sub-Zero Temperature (영하에서의 다짐에너지에 따른 다짐 효과 평가)

  • Lee, Jeonghyeop;Hwang, Bumsik;Chae, Deokho;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.13-20
    • /
    • 2015
  • Due to the population growth and exhaustion of resource, the development on the harsh environment such as cold weather is emerging as an alternative for new resource development. The permafrost area covers about 14 percent of the world's land area and the global construction market for such area is rapidly expanded. Whereas the developed countries have already recognition of the need for research of coldest place and invested heavily in technology development, the domestic technology for the coldest place development is less developed and related research has rarely been performed. There is not a detailed national specification standard for the strength and deformation properties of the earthworks at sub-zero temperature but simple field directions. Therefore, the D compaction tests were conducted on the sand with fine contents of 0%, 5%, 10% and 15% at room temperature ($18^{\circ}C$), $-3^{\circ}C$ and $-8^{\circ}C$ to investigate the effect of the compaction energy on the compacted soils at sub-zero temperatures. Based on the test results, the larger compaction energy, the larger maximum dry unit weight under sub-zero temperature and D type compaction at $-3^{\circ}C$ show similar max. dry unit weights as those obtained from the compaction at the room temperature. However, compaction at $-8^{\circ}C$ showed significant performance degradation regardless of the compaction energy.

Distribution and Migration Characteristics of Explosive Compounds in Soil at Military Shooting Ranges in Gyeonggi Province (경기도 북부지역 군용 사격장 토양에 존재하는 화약물질 분포 및 이동 특성 조사)

  • Bae, Bumhan;Park, Jieun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.17-29
    • /
    • 2014
  • A remedial investigation was conducted at five military training ranges in northern Gyeonggi province to collect information necessary for the design of on-site treatment facilities for the abatement of explosive compounds release to the environment. These information includes (i) identification of dominant explosive compounds in each range, (ii) discharge/migration routes, and (iii) contaminant distribution in particle size fraction and settling velocity of the soils. The results of investigation showed that TNT and RDX are the major contaminants but the extent of contamination varied depending on the types of military training practices and topography of the site. RDX was also detected in the subsurface soil and in the nearby stream within the training ranges, suggesting release of contaminants to streams. The median concentrations of explosives in the surface soil were less than 20 mg/kg despite several 'hot spots' in which explosives concentrations often exceeds several hundred mg/kg. The average clay contents in the soil of target area was less than 5 % compared to 12 % in the control, indicating loss of smaller particles by surface runoff during rainfall due to lack of vegetative land cover. Analysis of explosive compounds and particle size distribution showed that the amount of explosive compounds in soil particles smaller than 0.075 mm was less than 10 % of the total. Settling column tests also revealed that the quantity of explosive compounds in the liquid phase of the effluent was greater than that in the solid phase. Therefore, pre-treatment of particulate matter in surface runoff of shooting range with a simple settling basin and subsequent effluent treatment with planted constructed wetlands as polishing stage for explosives in the aqueous phase would provide the shooting ranges with a self-standing, sustainable, green solution.

Consolidation Characteristics & Consolidation Period of Dredged Soil by Considering Change of Strain and Stratum Thickness (변형률과 층 두께의 변화를 고려한 준설점토의 압밀특성과 압밀기간)

  • Cheong Gyu-Hyang;Kim Young-Nam;Ju Jae-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.105-114
    • /
    • 2004
  • Consolidation characteristics have been investigated by using Rowe cell consolidation tester for dredged soil, which is more than two times as much as the liquid limit. To examine the effects of variation of water content on consolidation characteristic, tests were carried out varying the initial water content from $100\%\;to\;150\%.$ The results were compared with the consolidation characteristics of remolded clay. The test results showed that the hither the initial water content of dredged clay was, the more noticeable the non-linear behavior of e-log P curves occurred. The variation of the gradient was apparent to load stage 40kPa and became less apparent after load stage 80kPa on the e-log P curves. Ratio of compression index stayed within the range suggested by Mesri and variation of initial water content has hardly influenced the coefficient of consolidation. On the contrary, it was found that the magnitude of consolidation load affects the vertical coefficient of consolidation. The variation of stratum thickness during consolidation processing needs to be taken into consideration since hydraulic fill would go through a much larger scale strain than land soil when it is subject to a load. In this study, the consolidation period considering the variation of stratum thickness was analyzed and the results were compared with those of existing consolidation studies which did not consider the variation of stratum thickness. According to the results of the study, the consolidation period of the ground with a larger strain was calculated more close to observed value in case of Mikasa theory which takes the variation of stratum thickness into consideration.

A Study of Hydrogen Embrittlement on a Material of CNG Storage Tank (CNG 저장용기 재료의 수소취성에 관한 연구)

  • Han, J.O.;Lee, Y.C.;Lee, J.S.;Chae, J.M.;Hong, S.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.9-14
    • /
    • 2011
  • A set of test was conducted on a SA-372 steel for CNG storage tank to study the effect of hydrogen embrittlement. Tensile tests were carried out several conditions such as CNG, HCNG and H2 gas environment including air and Ar under the 35 MPa. Also, the test speed was set at 4*10^-4/s and 4*10^-5/s respectively. To maintain the high pressure for environmental gas during test process, we chose MTS which was installed autoclave. Test results showed that tensile stress, elongation rate and cross sectional contraction under Ar and CNG charging condition were similar to that of reference of air. And there was little bit change with test speed variations. However, hydrogen added conditions such as HCNG and H2 were revealed noticeable change in elongation rate and cross sectional contraction. Tensile stress was still uniform for all conditions. From the results, the effect of hydrogen embrittlement was confirmed on the hydrogen enriched conditions. Also its effect was showed more strong with much hydrogen concentration and slower test speed.