• Title/Summary/Keyword: Environment Standard

Search Result 5,364, Processing Time 0.033 seconds

The Analytical Bias of Total Hydrocarbon (THC) Measurements in Relation to the Selection of Standard Gas Compound (총탄화수소의 계측에서 표준시료성분의 선택에 따른 오차 발생 연구)

  • Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.449-452
    • /
    • 2010
  • In this article, the performance of the THC analyzer was inspected using two different span gases of methane ($CH_4$) and propane ($C_3H_8$). To explore the effect of standard gas selection, MicroFID system was tested by the following procedures. Initially, the system is spanned by propane gas of 60 ppm (or 180 ppmC). The system is then run against methane standards prepared at 5 different concentrations of 200, 250, 300, 400, and 500 ppm. According to the suggestion of the KMOE's test procedure to use multiplying a factor of 3 (for propane), the resulting THC values derived by methane standards were systematically biased with ~500% error relative to true value. This paper discusses the interpretation procedures to obtain the least biased THC values for a given span set-up.

Study on the Application Possibility of Heating-cooling system with Smoke ventilation duct to Standard Apartment (공동주택의 제연겸용 덕트형 냉난방 공급시스템의 적용가능성에 관한 연구)

  • Chun, Jung-Gil;Park, Jung-Han;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.468-473
    • /
    • 2008
  • Currently, most of the buildings have been the high-rise buildings and not only the damage for people but also loose of property have been increased significantly. Furthermore, the damage for residents in indoor is increased significantly, the law related to fire protection is not established yet. We discussed safety of evacuation according to unitary system in standard apartment. At a result, when installing the smoke ventilation system, the RSET has been achieved and delay effect for reaching time of CO and smoke area has been obtained.

  • PDF

Open Standard Based 3D Urban Visualization and Video Fusion

  • Enkhbaatar, Lkhagva;Kim, Seong-Sam;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.4
    • /
    • pp.403-411
    • /
    • 2010
  • This research demonstrates a 3D virtual visualization of urban environment and video fusion for effective damage prevention and surveillance system using open standard. We present the visualization and interaction simulation method to increase the situational awareness and optimize the realization of environmental monitoring through the CCTV video and 3D virtual environment. New camera prototype was designed based on the camera frustum view model to project recorded video prospectively onto the virtual 3D environment. The demonstration was developed by the X3D, which is royalty-free open standard and run-time architecture, and it offers abilities to represent, control and share 3D spatial information via the internet browsers.

A Study on the Deterministic Evaluation Method of R&D Project in Food Industry (식품산업 연구개발의 결정론적 평가방법에 관한 연구)

  • 이종만;이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.14 no.23
    • /
    • pp.57-64
    • /
    • 1991
  • The preliminary, advanced and final evaluation of R&D project is essential in order to reduce loss of resource and opportunity and to minimize uncertainty resulting from optimal selection and efficient progress of R&D project. This thesis examined characteristics of deterministic evaluation, economical evaluation, and OR-approach evaluation as theoretical methodology of evaluation of R&D project applicable to food industry in Korea by using scoring method, one of deterministic evaluations. In addition, this thesis divided the evaluation factors for preliminary evaluation of R&D project into 5 groups and 30 factors on basis of the environment of domestic companies and set up the standard of each evaluation factors and contains marking-selecting way. But, generally, the evaluation model by this thesis, as the conditions of the business company environment are different to each other, contents to be set up evaluation factors, evaluation standard and decision method conforming to each the environment of the business companies with referring to as one standard of evaluation project for selecting R&D project.

  • PDF

A Comparison Study on the Method of Pollution Evaluation of Water Quality in the Stream (하천 수질의 오염도평가 방법의 비교 연구)

  • Lee, Ho-Beom;Lee, Jung-Ki;Shin, Dae-Yewn
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.398-403
    • /
    • 2005
  • This study is undertaken to find the optimal method to make the decision on the degree of water pollution by comparison of K-WQI, KOE-WQI that is made for index with the water quality index and water quality environment standard of the Frame Act on Environment Policy as the result of survey for water quality reality on the major point of the Yeongsan river from 2002 to 2004. The water quality of major rivers has some differences depending on seasons. however, under the water quality standard by the $BOD_5$ density, most of rivers displayed the water quality level of $II{\sim}III$ grading, and on K-WQI that is classified by indexing for 10 categories of pH, DO, $BOD_5,\;COD,\;SS,\;T-N,\;NH_3-N,\;NO_{3^-}$ N, T-P, and E-Coli and classified into 5 groups from 100 points to 40 points, they displayed the score distribution of the first grade in water quality for $85{\sim}100$ points to the second grade in water quality for $70{\sim}84$ points. On KOE-WQI that is classified by indexing for 5 categories of pH, DO, $BOD_5$, COD and T-coli and classified into 5 groups from 90 points or above for outstanding and 29 points or below for very bad, and the water quality distribution is made ranged from the first grade in water quality for 90 points or more to the third grade in water quality for $69{\sim}50$ points. In addition, for the contribution of the water quality decline, the Environmental standard has significant dependency on the $BOD_5$ density, with K-WQI contributing in various water quality decline depending on the environment around the river area of $BOD_5,\;T-N,\;NH_3-N,\;NO_3-N,\;T-P$, and E-Coli, and KOE-WQI acting os the factor contributing to lower the water quality decline by $BOD_5$, COD, and T-coli. As such, the current water quality environment standard has high dependency on $BOD_5$ and KOE-WQI excludes some nitrogen and phosphorus that considers the river environment that the grade in water quality is set by some category, and K-WQI reflected well of the ecology environment of rivers with the diversity of the assessment factor as well as to have the low dependency of specific factor to be objective.

A Study on the Standard Flow Chart for Civil Engineering (토목공학을 위한 표준 이수체계도에 관한 연구)

  • Choi, Se-Hyu;Park, Sung-Sik
    • Journal of Engineering Education Research
    • /
    • v.15 no.1
    • /
    • pp.3-8
    • /
    • 2012
  • This study present the standard flow chart for civil engineering considering Korean education environment. The flow charts of USA's 20 universities and Korea's 6 universities are investigated. The standard flow chart are proposed based on the standard curriculum of civil engineering and flow charts of USA and Korea though analyzing of prerequisite of each subject. The proposed standard flow chart is expected when used to improve korean universities curriculum.

Study on the Assessment of Air Quality Before and After Action Plan of Atmospheric Environment Improvement Establish at Gimhae, Gyeongnam Province (경남 김해지역의 대기환경개선 실천계획 수립 전후의 대기질 평가에 관한 연구)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Kim, Eun-Byul
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1111-1120
    • /
    • 2008
  • In order to study the degree of improved air quality as an outcome of the action plan of Atmospheric Environment Improvement in Gimhae, Gyeongnam Province, we investigated the status and trends of air pollutant before and after the plan. Nitrogen dioxide and ozone, both classified as hazardous substances, were closely monitored with particular attention. The level of sulfur dioxide, nitrogen dioxide, fine particles and ozone (but for carbon monoxide) was decreased after the plan was implemented. The number of days on which ozone exceeded the National Ambient Air Quality Standard has decreased, but the level was still often exceeded. The level of nitrogen dioxide did not surpass until the 2006 standard, but when the revised 2007 standard was implemented, it exceeded 80% of some standards. The yearly level of ozone has decreased since the plan was introduced. The concentration of nitrogen dioxide, however, has reduced in high order area while increased in low order area.

Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed- (시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로-)

  • Park, Jinhwan;Kang, Taewoo;Han, Sungwook;Baek, Seunggwon;Kang, Taegu;Yoo, Jechul;Kim, Youngsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.

Technical Review of the IAEA Regulations for Transportation of Radioactive Materials and Major Revision in the 1996 IAEA Safety Standard Series No. ST-l (IAEA 방사성물질 안전운송규정에 대한 요약과 1996년도판 개정의 요점)

  • Yoon, Jeong-Hyoun;Kim, Chang-Lak;Cho, Gyu-Seong;Choi, Heui-Joo;Park, Joo-Wan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.197-210
    • /
    • 1998
  • Regulations for the safe transport of radioactive material published by IAEA Safety Standard Series ST-l is reviewed and summarized. Safety Series No.115(International standard of radiation protection and safety for ionizing radiation and radiation sources), which reflected the new recommendation of ICRP60 published in 1991, has been a important encouragement for IAEA to revise their safety series related to the transportation of radioactive materials. IAEA Safety, Standard Series No. ST-l is summarized by comparing IAEA Safety Series No.6 regarding radiation protection system and its implementation, technical standards of packages, concept of Q system and exemption of regulation. The IAEA regulations of transportation of radioactive materials is summarized from the viewpoint of radiation protection and safety assessment. Research on transportation system of radioactive waste is suggested as a further study.

  • PDF

An Evaluation of Atmospheric Environmental Capacity in Daegu (대구지역 대기환경용량 산정에 관한 연구)

  • Park, Myung-Hee;Choi, Geun-Sik;Jung, Woo-Sik;Kim, Hae-Dong;Lee, Joon-Soo
    • Journal of Environmental Science International
    • /
    • v.19 no.10
    • /
    • pp.1271-1281
    • /
    • 2010
  • This study aims to implement the modeling of selected substances for the evaluation of Atmospheric Environmental Capacity by means of the data of 2006 atmospheric pollution substance emissions. As a result, it turned out that the substance with the concentration higher than Atmospheric Environmental standard concentration was NO2, and 17.6% of the total regions researched turned out to exceed the standard concentration. In addition, set was the targeted amount to be reduced in the areas where the upper limit of emission per unit lattice was exceeded, and the model was adopted accordingly. As a result, it turned out that about 80% of the actual emission should be reduced to meet the 2006 Atmospheric Environmental standard over the Daegu. In reality, it is impossible to reduce 80% of the actual emission. Thus, the same ratio of reduction was applied in all of the Daegu regions, and the modeling was applied. The results are as follows: When 30% was reduced, the level went down to 50 ppb, which is as high as 2006 Atmospheric Environmental standard; when 50% was reduced, the level went down to 30 ppb, which is as high as 2007 Atmospheric Environmental standard.