• Title/Summary/Keyword: Envelope design

Search Result 303, Processing Time 0.029 seconds

Kinematic Envelope Effect Analysis of the Urban Transit EMU According to PSD Installation (PSD 설치에 따른 도시철도차량의 Kinematic Envelope 영향 분석)

  • Chung, Jong-Duk;Pyun, Jang-Sik;Cho, Hui-Je;Hong, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1779-1784
    • /
    • 2010
  • Since PSD(Platform Screen Door) is set up at many subway stations, its design related to a safety becomes gradually important. Especially the intereference check with a running railway vehicle is the most important of performance indices. This study proposes a dynamic analysis models for the railway vehicle and rail. Some design parameters are considered in the models to find a correlation to the performance.

  • PDF

A Study on the Development of Building Envelope Elements for Energy Reduction in Multi- Rise Residential Buildings

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.18 no.4
    • /
    • pp.151-155
    • /
    • 2016
  • It is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to find an optimal thermal transmittance (U-values) for building envelope elements for low energy multi-rise residential buildings in the early design phase in Korea. The study found that using small U-values of $0.15w/m^2K$ for exterior walls, ceilings and floors and $1.0w/m^2K$ for south and north facing windows has resulted in energy reduction of 22.1%-59.4% in the south facing rooms and 43%-77.6% of the north facing rooms. It has also found the energy load reduction potential of using small U-values are higher on the north facing rooms. The findings of this study can be suggested to be used as a baseline case for low energy consumption studies. It can also be used to determine appropriate envelope materials and insulation values.

Evaluation Method for Non-linear Shear Strength of Gravel Materials (자갈질 재료의 비선형적 전단강도 특성 평가법)

  • Shin, Dong-Hoon;Cho, Seong-Eun;Lim, Eun-Sang;Park, Han-Gyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.288-298
    • /
    • 2009
  • It is well known that the peak strength envelope of geomaterials with no cohesion, such as sand, gravel and rockfill, exhibits significant curvature over a range of stresses. In a practical design of slope, however, the linear Mohr-Coulomb's failure envelope is used as a failure criterion and consequently gives inaccurate safety factors, especially for some ranges of small normal stresses on shallow failure surfaces. Necessity of a nonlinear shear strength envelope in slope stability analysis is on this point. Hence, this study describes how to evaluate nonlinear shear strength of gravel fill materials using the results of large triaxial tests under consolidated-drained condition, and compares the safety factors from slope stability analyses for a homogeneous gravel fill or rockfill embankment incorporating the non-linearity of strength, so as to show its effects on safety factors.

  • PDF

A qualitative evaluation method for engine and its operating-envelope using GSP (Gas turbine Simulation Program)

  • Kyung, Kyu-Hyung;Jun, Yong-Min;Yang, Soo-Seok;Choi, Dong-Whan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.848-853
    • /
    • 2004
  • Regarding to the project SUAV (Smart Unmanned Aerial Vehicle) in KARI (Korea Aerospace Research Institute), several engine configurations has been evaluated. However it's not an easy task to collect all the necessary data of each engine for the analysis. Usually, some kind of modeling technique is required in order to determine the unknown data. In the present paper a qualitative method for reverse engineering is proposed, in order to identify some design patterns and relationships between parameters. The method can be used to estimate several parameters that usually are not provided by the manufacturer. The method consists of modeling an existing engine and through a simulation, compare its transient behavior with its operating envelope. In the simulation several parameters such as thermodynamics, performance, safety and mechanics concerning to the definition of operation-envelope, have been discussed qualitatively. With the model, all engine parameters can be estimated with acceptable accuracy, making possible the study of dependencies among different parameters such as power-turbine total inertia, TIT, take-off time and part load, in order to check if the engine transient performance is within the design criteria. For more realistic approach and more detailed design requirements, it will be necessary to enhance the compressor map first, and more realistic estimated values must be taken into account for intake-loss, bleed-air and auxiliary power extraction. The relative importance of these “unknown” parameters must be evaluated using sensitivity analysis in the future evaluation. Moreover, fluid dynamics, thermal analysis and stress analysis necessary for the resulting life assessment of en engine, will not be addressed here but in a future paper. With the methodology presented in the paper was possible to infer the relationships between operation-envelope and engine parameters.

  • PDF

Construction of Design Table for Envelope Curve Analysis of Base Isolated Buildings (면진건물의 포락해석을 위한 설계용 도표 산정면진건물의 포락해석을 위한 설계용 도표 산정면진건물의 포락해석을 위한 설계용 도표 산정)

  • Lee, Hyun-Ho;Cheon, Yeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.59-67
    • /
    • 2006
  • The aim of this study is to evaluate the design table for envelope curve analysis of base isolated buildings, which represent the period of base isolated buildings and the lateral displacement of base isolation devices. For the construction of design table, $V_E$ spectrum, which represents the energy, is developed instead of acceleration of seismic hazard. Based on the seismic coefficient of UBC 97, boundary period $T_G$ and maximum velocity response $V_0$ are proposed considering Korea seismic hazard. Using $T_G$ and $V_0$, finally, $V_E$ spectrum is developed for the four types of soil conditions. Base on the $V_E$ spectrum, design table for envelope curve analysis is also developed for soil types.

Optimization of Harmonic Tuning Circuit vary as Drain Voltage of Class F Power Amplifier (Class F 전력 증폭기의 드레인 전압 변화에 따른 고조파 조정 회로의 최적화)

  • Lee, Chong-Min;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.1
    • /
    • pp.102-106
    • /
    • 2009
  • This paper presents the design and optimization of output matching network according to envelope for class F power amplifier(PA) which is to apply to envelope elimination and restoration(EER) transmitter. In this paper, to increase the PAE of class F power amplifier which applies to EER transmitter, the varactor diode has been used on output matching network. As envelope changes, it optimizes constitution of harmonic trap that is short circuit in 2nd-harmonic and is open circuit in 3rd-harmonic. When drain voltage changes from 25 V to 30 V, some percentage is improved in the PAE.put the abstract of paper here.

The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling (사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석)

  • Choi, Seon woo;Kim, Ji Yeon;Park, Hyo soon;Kim, Jun Tae
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

A Multi-Polynomial Synthesis Method for DRRD Cam Profile Optimizations and Effects of Shape Factors on the Cam Lobe Area (DRRD 캠 형상 최적 설계를 위한 다항식 합성법과 캠 로우브 면적에 미치는 형상 계수들의 영향)

  • 김도중;박성태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.4
    • /
    • pp.59-71
    • /
    • 1994
  • A multi-polynomial method is proposed to synthesize DRRD cam profiles. A cam lift duration s divided into 10 sections, each of them is expressed by a polynomial equation. 12 design variables are extracted from the cam profile displacement, velocity, and acceleration curves. Because all the design variables have physical meanings which are familiar to most cam designers, it is easy to imagine a profile shape from the design variables. The design envelope of the method is wide enough to be used in DRRD automotive cam designs. Polydyne cams, widely used in automotive engines, are included into the envelope. Unlike Polydyne cams, the method provides capability of wide velocity factor variations, which gives much flexibility in flat-faced tappet design. Area factor of profiles designed by the method can be increased 5-10% compared to those of Polydyne cams without increasing acceleration factor. The method is especially useful for cam profile optimizations.

  • PDF

Sensitivity Analysis of Building Envelope of Non-Dwelling Buildings (비주거 건축물의 외피요소에 대한 민감도 분석)

  • Kim, Kyung-Ah;Park, Jin-Seo;Yu, Ki-Hyung;Moon, Hyeun-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • The ECO2 building energy simulation program is used on the assessment project for building energy certification of non-dwelling buildings in Korea. In the design of energy efficient buildings, it is beneficial to identify the most important design parameters in oder to more efficiently develop alternative design solutions or reach optimized design solutions. The sensitivity analyses will be used at a reasonable early stage of the building design process, where it is still possible to influence the most important design parameters. In this study, the sensitivity analysis is focused on building envelope parameters such as U-values, SHGC and Wall-window ration.

Effect of the building envelope on heating and cooling load in super tall building considering the meteorological changes with height (높이별 기상변화를 고려한 초고층 건축물의 외피종류별 냉난방 부하특성 분석)

  • Choi, Jong-Kyu;Kim, Yang-Soo;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.337-344
    • /
    • 2012
  • Today, the number of super tall buildings are under construction or being planed in Middle East and Asian Countries. For example the burj Khalifa, the tallest building in the world, is completed in 2008 and the height of that is about 800m. Also, Lotte World Tower is under construction in Korea. External environmental conditions such as wind speed, air temperature, humidity and solar radiation around the super tall building differs according to the building height due to the vertical micro climate change. However, the meteorological information used for AC design of building is obtained typically from standard surface meterological station data(~2m above the ground). In this paper the effect of the building envelope on heating and cooling load in super tall building considering the meteorological changes with height was analyzed with simulation method. As results of this research, the guideline to select the building envelop alternatives for super tall building will be suggested in this paper.

  • PDF