• Title/Summary/Keyword: Entrance Speed

Search Result 146, Processing Time 0.027 seconds

A Study on the Signal Progression System for the Disaster Prevention of Traffic Facilities - A case study of Dong Moon Ro in Kwangju City - (교통시설 재해방지를 위한 신호체계 연동화에 관한 연구 - 광주시 동문로를 중심으로 -)

  • Hwang, Eui Jin;Ryu, Ji Hyeob;Lim, Ik Hyun
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.3
    • /
    • pp.59-67
    • /
    • 2008
  • The most influential facility causing traffic disaster on the urban road is intersection. Accordingly, this study elected a region for case study from seabang three-way junction, partial section of Dongmoon Ro in Kwang-Ju city, to the intersection of Mudeung Library Entrance. It is believed that the signal progression is very effective on the basis of short interval of intersection and massive traffic volume. The signal progression was simulated by using TRANSYT-7F model. The following is summary of the simulation: According to the change of cycle length, P.I. delay and fuel consumption showed the tendency of being increased in case that cycle length becomes long or short, centering around the best cycle length. In the event of progressing the cycle length, the average speed per vehicle is increased by 11.39Km per hour and P.I value is improved by 40.65% so that it resulted in 42.86% improvement in the total travel time. Moreover, the fuel consumption in line with the progression practice produced fuel saving of 31.04%.

  • PDF

Importance and Satisfaction Rating Assessment of users Regarding BRT Facility and Operation : The Case of Busan (BRT 시설 및 운영에 관한 이용자의 중요도 만족도 평가 : 부산광역시를 중심으로)

  • Kim, Seong Eun;Jung, Hun Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.595-603
    • /
    • 2019
  • To alleviate the demand on private car that is constantly increasing, Busan Metropolitan City (BMC) has established Bus Rapid Transit (BRT) to revitalize public transportation. But there are no unified lane system between BRT and general bus stations, which makes off-lane turning general bus to contribute to congestion. And as the bottleneck phenomenon at entrance/exit accelerates the congestion, there has been huge dissatisfaction among commuting drivers. Therefore, this study identifies efficient methods to operate better through measuring civilian awareness. We evaluate both satisfaction and drawbacks on BRT service with Importance-Performance Analysis (IPA). We first distinguish the groups by the awareness on BRT and their main transit usage, and then clarify the difference between the groups. And as a result, the group who is positive to BRT and uses buses often demands improvement in bus indoor comfort and curbing jaywalking. On the other hand, group who is negative to BRT and uses private cars often demands improvement in lane changing and the moving speed of private cars. We next examines the groups with MDPREF, one method of Multidimensional Scaling (MDS). And we have clarified that the evaluating criteria and the individual attributes of the groups corresponds very well.

A study on the utilization of abrasive waterjet for mechanical excavation of hard rock in vertical shaft construction (고강도 암반에서 수직구 기계굴착을 위한 연마재 워터젯 활용에 관한 연구)

  • Seon-Ah Jo;Ju-Hwan Jung;Hee-Hwan Ryu;Jun-Sik Park;Tae-Min Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.5
    • /
    • pp.357-371
    • /
    • 2023
  • In cable tunnel construction using TBM, the vertical shaft is an essential structure for entrance and exit of TBM equipment and power lines. Since a shaft penetrates the ground vertically, it often encounters rock mass. Blasting or rock splitting methods, which are mainly used to the rock excavation, cause public complaints due to the noise, vibration and road occupation. Therefore, mechanical excavation using vertical shaft excavation machine are considered as an alternative to the conventional methods. However, at the current level of technology, the vertical excavation machine has limitation in its performance when applied for high strength rock with a compressive strength of more than 120 MPa. In this study, the potential utilization of waterjet technology as an excavation assistance method was investigated to improve mechanical excavation performance in the hard rock formations. Rock cutting experiments were conducted to verify the cutting performance of the abrasive waterjet. Based on the experimental result, it was found that ensuring excavation performance with respect to changing in ground conditions can be achieved by adjusting waterjet parameters such as standoff distance, traverse speed and water pressure. In addition, based on the relationship between excavation performance, uniaxial compressive strength and RQD, it was suggested that excavation performance could be improved by artificially creating joints using the abrasive waterjet. It is expected that these research results can be utilized as fundamental data for the introduction of vertical shaft excavation machines in the future.

A Study on the Characteristics of Design and Acculturation of Planting of 'Guǐ(槐)' in Chirinjeong Wonlim of Pohang (포항 칠인정원림(七印亭園林)의 조영특성과 '괴목(槐木)' 식재(植栽)의 문화변용(文化變容))

  • Rho, Jae-Hyun;Han, Sang-Yup;Kim, Jeong-Moon;Jeong, Poo-Reum
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.22-31
    • /
    • 2017
  • The purpose of this study is to illuminate historical sensitivity and design in the days of the Joseon era and examines the phenomenon of acculturation as revealed in the planting of Sophora japonica and Zelkova serrata in the garden grove by looking into the purpose underlying the construction, formative intention and the process of change in Pohang's Chirinjeong wonlim. Chirinjeong, also called Sanggaejeong(雙槐亭) after the fact that two Zelkova serrata trees were planted there, is a hermit pavilion in Sa-il village, Chogok-ri, built in the 9th year of King Taejong(1409) by Jang, Pyo(張彪, 1349~?) of an officer of bureaucratic origin toward the end of the Goryeo Dynasty, the Chirinjeong garden grove is an element essential to Chogok, the 3rd Gok of Sanggaegoogok(雙溪九曲). The wonlim of Chirinjeong is divided into the pavilion section composed of the entrance area, Chirinjeong, composed of Zelkova serrata and Sophora japonica, and the pond section composed of a quadrangular pond and island(方池方島), and Lagerstroemia indica. In view of the intent of the name Chirinjeong or of the fact that the pavilion was named based on that the royal seal string was hung on the Sanggwaesoo(雙槐樹) or two Zelkova serrata trees, it is reasonable to view it as Zelkova serrata trees having been planted early in the days of the Joseon Dynasty and those additionally planted later on that symbolizes the position of the three nobles and the Sophora japonica. In addition, in spite of the fact that the type of trees supplementarily planted in the 21st year of King Yeongjo(1745) is known as Sophora japonica, it is impossible to rule out the possibility of the tree planted outside of Chirinjeong being Zelkova serrata. In short, the three Zelkova serrata trees planted along with Sophora japonica must certainly be evidence that Zelkova serrata planted along with Sophora japonica in Chirinjeong wonlim indicates that the off spring of the Indong Jang family could tell the difference between Sophora japonica and Zelkova serrata. In the recognition process of Zelkova serrata trees finding their way into Korea, it was known as Zelkova serrata on the one hand and as Sophora japonica on the other, and the former, which enjoys a comparative advantage over in terms of the easiness with which to purchase, growth speed and possibility of growing into a long-lived tree was interchanged with Zelkova serrata, a case of acculturation as manifested in the planting of Sophora japonica in the Chirinjeong garden grove.

Study on the Anchovy Boat Seine - II - On The Hydrodynamic Resistance and Performance of Patti-net (기선권현망의 연구 II - 파치망의 유체저항과 그물꼴에 관하여 -)

  • Lee, Byoung-Gee;Su, Young-Tae;Han, Hi-Soo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.63-68
    • /
    • 1978
  • A boat seine has been used as a major fishing gear for catching anchovy (Engraulis japonica) in the southern coastal waters of Korea since the 1920s. Since the 1950s some improvement from the original seine has been made; powered boats equipped with net hauler has been used instead of rowing boats with hand-driven capstan, and the seining method has been changed into the trawling method. But even now, there are many problems to be solved in the view point of decreasing man power without decreasing catching efficiency. For the purpose, patti-net has been introduced from Japan and experimented on the commercial base since 1972, and it was known that the patti-net could be operated with man power as half as needed in the coventional net, but catching efficiency was not so desirable. Therefore, the study on the characteristics of it were required. The authors carried out a model experiment with a Qne-twentieth scale model net towed by a powered boat on the sea. The obtained results run as follows: 1. Hydrodynamic resistance of the model net can be explained as $R_p=69.6 V_{I.66}$ $R_h=37 v^2$ where $R_p$ and $R_b$ denote the resistance of the whole gear and the cod end in kg respectively, and v the towing speed in mlsec. 2. Performance of wing and cod end showed no deformation such as observed at the conventional net. 3. The ratio of opening at the entrance of bag net to that of cod end showed about 2: 1. Therefore, when we intend to enlarge the net to be able to operate in the deep fishing ground, the cod end should be enlarged in the same proportion and increased towing power is needed .. Then, it will be better to increase the ratio for increasing fishing efficiency without increasing towing power.

  • PDF

Mitigation of Insufficient Capacity Problems of Central Bus Stops by Controlling Effective Green Time (유효녹색시간 조정을 활용한 중앙버스정류장 용량 부족 완화 방안 연구)

  • Koo, Kyo Min;Lee, Jae Duk;Ahn, Se Young;Chang, Iljoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.1
    • /
    • pp.35-50
    • /
    • 2022
  • After the introduction of the central bus lane system, bus traffic was prioritized. This resulted in improved trust from bus users. However, the low capacity at the central bus stop reduces traffic speed and punctuality. In addition, physical constraints are inevitable because the construction of central bus lanes and bus stops considers the city's road geometry. Therefore, this study attempted to optimize the effective green time of the traffic signal system at the entrance and exit of the central bus stop to remedy its insufficient operational capacity. The Transit Capacity and Quality of Service Manual and Korea Highway Capacity Manual were used as the analysis methodologies. The number of stop areas for central bus stops to be built was determined by excluding variable physical factors, and field survey data collected from nine randomly selected central bus stops currently installed in Seoul were used. A scenario analysis was conducted on the central bus stops with insufficient capacity by adjusting the effective green time, and the capacity of the central bus stop was set as the dependent variable. According to the results, 26.7 percent of the central bus stops with insufficient capacity can solve the problem of insufficient capacity. Therefore, the results of this study can be verified by improving the operation level, and it can be effective even if the number of central bus stops calculated by engineering is not guaranteed during the planning stage of the central bus stop. As the number of central bus stops is expected to increase further as the number of central bus stops increases, it is necessary to improve the number of central bus stops. Therefore, it is hoped that the results presented in this study will be used as basic data for the improvement plan at the operational level before introducing the physical improvement plan.