• Title/Summary/Keyword: Enthalpy efficiency

검색결과 77건 처리시간 0.022초

빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구 (The Novel Configuration for Building Energy System Including Build ins Microgrid)

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

고정격자를 이용한 동결건조 해석프로그램의 개발 (Development of Freeze Drying Analysis Program using Fixed Grid)

  • 남진현;송치성;김찬중
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.923-931
    • /
    • 2004
  • A multi-dimensional freeze drying analysis program, which took simultaneous heat and mass transfer, sublimation of ice and motion of sublimation front into full account, was developed using finite volume method with fixed grid. The effect due to the motion of sublimation interface was modeled by an enthalpy formulation streamlined for the freeze drying problems. The efficiency and accuracy of the program was validated by solving one- and two-dimensional freeze drying problems frequently encountered in industrial processes. Finally, the freeze drying processes of cylinder and slab objects with permeable side surfaces were simulated, which demonstrated the capability of the present analysis program in solving multi-dimensional freeze drying problems with complex sublimation interface configurations.

하절기 기화냉각장치 설치에 따른 가스터빈 성능변화 (Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season)

  • 정현조;유호선;문승재
    • 플랜트 저널
    • /
    • 제13권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 본 연구는 하절기 가스터빈 압축기 입구에 설치된 기화냉각장치로 인하여 저하된 공기온도가 가스터빈 성능에 어떠한 변화를 미치는지에 대하여 해석하였다. 연구 대상은 인천화력본부 가스터빈 3호기이며, 기종은 Siemens SGT6-4000F(V 84.3A)이다. 기화냉각장치 설치 전후를 비교하기 위하여 특설계측기를 설치하였으며, 2015년 8월 3일에서 14일까지 11시부터 15시 사이에 대기온도 $29{\pm}1^{\circ}C$ 조건에서 설치 전후 각각 5회씩 총 10회에 걸쳐 정밀성능시험을 시행하고 각각의 평균값을 적용하였다. 시험 결과, 가스터빈 압축기 입구 공기온도 $4.12^{\circ}C$ 저하로 공기 밀도가 증가되어 압축기 압력비는 0.27 증가, 압축기 효율은 0.29 %p 상승, 가스터빈 엔탈피강하 효율은 0.31 %p 증가하였고, 가스터빈 효율은 0.44%p, 출력은 4,489 kW가 증대되는 효과를 얻을 수 있었으며, 습도 및 유동저항 증가에 따른 영향은 미미하였다.

  • PDF

폐기물 소각시설 굴뚝의 배기가스를 이용한 유기랭킨사이클 시스템의 열역학적 해석 (Thermodynamic Analysis on Organic Rankine Cycle Using Exhaust Gas of the Chimney in a Resource Recovery Facility)

  • 김선희;성태홍;김경천
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.27-35
    • /
    • 2017
  • 폐기물 소각시설 굴뚝의 배기가스를 측정하여 활용 가능한 폐열의 양과 질을 확인한 바 그 양과 온도는 13.8kg/s, $176.6^{\circ}C$ 정도였다. 본 연구에서는 R-245fa를 작동유체로 하는 소각폐열회수 유기랭킨사이클(Organic Rankine Cycle: ORC) 발전시스템을 설계하고 다음과 같이 3가지 사례조건들을 시뮬레이션을 하였다. 기본 ORC 시스템에 따른 시뮬레이션에서는 출력과 총효율이 각각 96.56kW, 14.13% 임을 확인하였다. 과열기 추가에 따른 시뮬레이션에서는 작동유체 과열에 따른 엔탈피 증가로 0.09%의 출력상승을 얻을 수 있었으나, 작동유체의 감소로 16.58kW 만큼 적은 출력을 보였다. 그리고 공정열교환기 추가에 따른 시뮬레이션에서는 남은 배기가스의 열을 공정열수를 생산하여 총효율 38.51%까지 향상시켰다.

헵탄의 화원 직경 변화를 고려한 대형콘칼로리미터의 발열량 측정 결과 분석 (Analysis of Heat Release Rate with Various Diameter of Heptane Pool Fire Using Large Scale Cone Calorimeter)

  • 유우준;남동군;염문천;김성찬;유홍선
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.1-7
    • /
    • 2014
  • 본 연구에서는 대형 콘 칼로리미터(large scale cone calorimeter, LSC)를 사용하여 헵탄 풀 화재(pool fire) 실험에서 화원의 직경 변화에 따른 발열량(HRR) 측정 결과를 정량적으로 분석하였다. 발열량에 중요한 영향을 미치는 연소율(burning rate)은 A. Hamins의 연구 자료에서 제시한 모델링 곡선과 비교하여 정확성을 검증하였으며, 산소 소모법에 의한 연소효율(combustion efficiency)은 이론발열량에 비해서 91% 정도로 J. Gore이 제시한 헵탄의 연소효율 92%와 유사한 것을 확인하였다. 엔탈피소모법에 의한 열손실은 전체 발열량의 54% 정도로 측정부에서 대류 발열량으로 측정되었으며, 본 연구 결과는 화재실험에서 발열량 측정값의 신뢰성 분석(reliability analysis)을 위한 기초 연구 자료로 활용하는데 유용한 정보가 될 것으로 사료된다.

석탄계 활성탄에 의한 수중의 메틸렌블루와 페놀 흡착 특성 (Adsorption Characteristics of Methylene Blue and Phenol from Aqueous Solution using Coal-based Activated Carbon)

  • 이송우;감상규;이민규
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1161-1170
    • /
    • 2013
  • The efficiency of coal-based activated carbon in removing methylene blue (MB) and phenol from aqueous solution was investigated in batch experiments. The batch adsorption kinetics were described by applying pseudo-first-order, pseudo-second-order, and first order reversible reaction. The results showed that the adsorption of MB and phenol occurs complexed process including external mass transfer and intraparticle diffusion. The maximum adsorption capacity obtained from Langmuir isotherm was 461.0 mg/g for MB and 194.6 mg/g for phenol, respectively. The values of activation parameters such as free energy (${\Delta}G^0$), enthalpy (${\Delta}H^0$), and entropy (${\Delta}S^0$) were also determined as -19.0~-14.9 kJ/mol, 25.4 kJ/mol, and 135.2 J/mol K for MB and 51.8~54.1 kJ/mol, -29.0 kJ/mol, and -76.4 kJ/mol K for phenol, respectively. The MB adsorption was found to be endothermic and spontaneous process. However, the CV adsorption was found to be exothermic and non-spontaneous process.

마이크로 동력발생용 소형 스위스롤 연소기의 크기와 형상 효과에 대한 연구 (Effect of Scale and Geometry on the Performance of Heat-Recirculating Swiss roll combustors for Micro Power Generation Applications)

  • 오화영;허환일
    • 한국추진공학회지
    • /
    • 제15권1호
    • /
    • pp.1-10
    • /
    • 2011
  • 가스연소와 촉매연소 실험을 통해 열교환 연소기의 연소 및 소염한계에 대하여 레이놀즈 수에 적용하여 성능평가를 수행하였으며, 마이크로 스케일 연소 장치에 대한 적용 가능성에 대해 살펴보았다. 본 논문에서는 연소기의 특성을 살펴보기 위해 나선형 연소기의 물리적 크기와 회전수를 변화시킨 스위스롤 연소기를 제작하여 실험을 수행하였다. 또한 연소가스 분석을 통한 연소효율에 대해서도 살펴보았다. 실험 결과를 바탕으로 스위스롤 연소기의 최적 작동상태에 대해서도 분석하였다.

PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성) (Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

선박폐열회수(WHRS) ORC 시스템의 과열기 구성에 따른 특성 해석 (An analysis on the characteristics of superheater organization of ORC system for marine waste heat recovery system(WHRS))

  • 김종권;김유택;강호근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.8-14
    • /
    • 2014
  • 본 연구에서는 R-245fa를 작동유체로 하는 250kW급의 선박폐열회수 발전 시스템을 설계하고 과열기의 구성에 따른 사이클 특성을 연구 하였다. 과열기와 증발기의 직렬연결과 병렬연결의 2가지 조건을 시뮬레이션 하였다. 과열기와 증발기의 직렬연결 시뮬레이션에서는 작동유체 과열에 따른 엔탈피 증가로 4.7%의 출력상승을 얻을 수 있었고, 목표출력을 250kW로 정하였을 경우에는 사이클유량을 4.1% 감소시킬 수 있었다. 과열기와 증발기의 병렬연결 시뮬레이션에서는 사이클의 목표출력을 250kW로 정하였을 경우에 과열기로 가는 열원유체의 유량이 증가함에 따라 사이클 유량이 감소하여 작동유체펌프의 소요동력이 최대 7.9% 감소 하였으며, 유량비율에 따른 사이클효율과 정미효율은 큰 변화가 없었다.

Preparation and Application of Polyurethane-urea Microcapsules Containing Phase Change Materials

  • Kwon Ji-Yun;Kim Han-Do
    • Fibers and Polymers
    • /
    • 제7권1호
    • /
    • pp.12-19
    • /
    • 2006
  • For thermal adaptable fabrics, the polyurethane-urea microcapsules containing phase-change materials (PCMs: hexadecane, octadecane and eicosane) were successfully synthesized by interfacial polycondensation using 2,4-toluene diisocyanate (TDI)/poly(ethylene glycol) (PEG400)/ethylene diamine (EDA) as shell monomers and nonionic surfactant NP-12 in an emulsion system under stirring rates of $3,000{\sim}13,000$ rpm. The mean particle size of microcapsule decreased significantly with increasing the stirring rate up to 11,000 rpm, and then leveled off. The mean particle size increased with increasing the content and molecular weight (eicosane > octadecane > hexadecane) of PCMs at the same stirring rate. The mean particle sizes of microcapsules were found to decrease with increasing the NP-12 content up to 1.5 wt%, and thereafter increased a little. It was found that the melting temperature ($T_m$) and crystallization temperature ($T_c$) of three kinds of encapsulated PCMs and their enthalpy changes (${\Delta}H_m,{\Delta}H_c$) increased with increasing PCM contents. The encapsulation efficiencies (Ee) of hexadecane microcapsule linearly increased with increasing the content of hexadecane. It was found that the stable microcapsule containing 50 wt% of hexadecane could be obtained in this study. However, Ee of octadecane and eicosane microcapsules increased with increasing PCM's contents up to 40 wt%, and then decreased a little. By considering the encapsulation efficiency, it was found that the maximum/optimum contents of octadecane and eicosane microcapsules were about 40 wt%. By the dynamic thermal performance test, it was found that the maximum buffering levels of Nylon fabrics coated with hexadecane, octadecane, and eicosane microcapsules were about $-2.4/+2.9^{\circ}C,\;-3.6/+3.6^{\circ}C\;and\;-4.0/+4.7^{\circ}C$, respectively.