• Title/Summary/Keyword: Enthalpy Method

Search Result 247, Processing Time 0.025 seconds

Experimental Study of Heat Transfer Performance of Louver-Fin Heat Exchanger (Louver-Fin 열교환기의 열전달 특성 실험 연구)

  • Chang, K.S.;Kweon, Y.C.;Hong, S.R.;Kim, J.D.;Lee, H.S.;Park, B.K.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.209-215
    • /
    • 2007
  • This study presents the air side heat transfer and friction characteristics of fin-tube heat exchangers. Variations of heat transfer performance in each row are investigated in the present work. Experiments were performed for the Louver fin-tube heat exchangers using air-enthalpy type calorimeter, which is based on air-enthalpy method described in ASHRAE standards. The air velocity was varied from 0.7 to 2.5 m/s with 0.3 m/s interval. The results are plotted in terms of Colburn j-factor and friction factor of with respect to Reynolds number in the range of 200 to 1100.

  • PDF

Numerical Study on Laser-driven In-Tube Accelerator (LITA) Performance using a Plasma Size Modeling

  • Kim, Sukyum;Toshiro Ohtani;Akihiro Sasoh;Jeung, In-Seuck;Park, Jeong--Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.320-324
    • /
    • 2004
  • Laser Propulsion is a device that generates thrust using laser energy. Laser-driven In-Tube Accelerator (LITA) has been developed at Tohoku University. LITA is a laser propulsion system that accelerates an object not in an open air but in a tube. Experiments of vertical launching and pressure measurement on the tube wall were carried out and in order to observe the initial state of plasma and blast wave, the visualization experiment was carried out using the shadowgraph method. In this study, the time variation of pressure on the tube wall is numerically simulated solving Euler equation. In order to model the laser energy, heat source function added to the frozen flow Euler equation. Plasma size from the shadowgraph images was used for the initial condition of laser energy input. For verification of the modeling, these results were compared with the previous experimental and numerical results. From these verifications, an analysis of LITA performance will be investigated.

  • PDF

A Study of Static Fatigue of Domestic Soda-Lime Glass (국산 Soda-석탄유리의 피노현상에 관한 연구)

  • 이희수;현상훈;이형복
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.1
    • /
    • pp.16-22
    • /
    • 1975
  • The network structure of a glass is known to be cracked by a chemical reaction, diffusion, and ion exchange of alkali ion, formed at the crack tip of the glass surface, when water is present on the glass surface. Since the durability of glass is reduced, due to the fatigue phenomenon mentioned above, pollution problem of glass goods, especially bottle glass, is becoming acute gradually. A static fatigue phenomenon was studied thermodynamically in this paper, and a mechanism of static fatigue, a quality control, and a method of preventing pollution for the main local glass goods were also investigated. The PH of reacted solution and the quantity of extracted alkali were measured at different conditions such as temperature, reacting time, particle size of a crushed glass sample, and the nature of reacting solution. The enthalpy change was calculated from the Arrhenius equation. The results are given below; 1) The absolute value of enthalpy change for the bottle glass was found to be higher than the for the flat glass. 2) The fatigue phenomenon of a glass was more sensitive to the temperature than to the reacting time. 3) The durability of glass in acid solution is stronger than in alkaline solution. 4) The substance which cracks the network structure of glas is considered the hydroxyl ion.

  • PDF

Optimization of Sous-Vide Brown Rice and Its Retrogradation Properties (수비드 현미밥의 최적 레시피와 노화도 분석)

  • Chun Young Sohn;Eun A Ko;Weon Sun Shin
    • The Korean Journal of Food And Nutrition
    • /
    • v.36 no.6
    • /
    • pp.581-587
    • /
    • 2023
  • Brown rice has various health benefits; however, it is more difficult to cook and has a harder texture as compared to milled rice. In this study, the effect of the sous-vide cooking method on starch retrogradation and textural properties of brown rice was investigated by comparative analysis with conventionally cooked brown rice based on moisture content assay, evaluation of the textural property analysis, and differential scanning calorimetry (DSC). The results of the study are as follows: First, the moisture content of sous-vide cooked brown rice was higher than in the conventionally cooked brown rice. Second, the sous-vide cooked brown rice has lower hardness, higher adhesiveness, and lower retrogradation enthalpy during storage than conventionally cooked brown rice. Finally, the retrogradation properties of cooked brown rice during storage were analyzed by DSC. The enthalpy increased more rapidly in the case of conventional cooked brown rice, reaching 1.58 J/g after 3 days of storage. This indicated that sous-vide cooking is effective in preventing retrogradation of rice during storage.

A Numerical Study on the Discharging Performance of a Packing Module in a Thermal Storage Tank (축열조 내 패킹 모듈의 방열 성능에 대한 수치해석)

  • Lee, Yong Tae;Chung, Jae Dong;Park, Hyoung Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.625-631
    • /
    • 2015
  • In this study, a numerical analysis on the discharging performance of a thermal storage tank completely filled with packing modules is investigated. The enthalpy-porosity method is adopted to analyze phase change phenomenon. Using this method, the melting process of a packing module in the thermal storage tank was studied as the HTF (heat transfer fluid) flows down from the top of the tank at the discharging mode. There are some design factors such as the module arrangement and the number of modules, but this study focuses on the effects of varying the flow rate of the HTF on the outlet temperature of the HTF, molten fraction, and thermal storage density. As the flow rate increases, the outlet temperature of the HTF gets higher and the total melting time of the PCM decreases. Additionally, the thermal storage density is increased so that it reaches about 93% for the desired value.

Structural and Thermal Characteristics of Synthesized SiC by Carbothermal Reaction and Sol-gel Method (Carbothermal 반응법과 졸-겔법에 의해 합성된 SiC의 구조적 특성과 열역학적 특성)

  • Oh, Won-Chun;Kim, Bum-Soo
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.156-160
    • /
    • 1998
  • SiC is synthesized by sol-gel and carbothermal reaction method from various carbon sources and Si source and characterized through the results of DSC and XRD. More SiC has been formed in carbothermal reaction than sol-gel method. From the XRD results, the degree of formation of SiC increases in the order of petroleum cokes, activated carbon, artificial graphite all in two introduced methods. Based on the DSC data, the enthalpy values for the exothermic reaction decrease in the order of activated carbon, petroleum cokes, artificial graphite in carbothermal reaction methods, while those for the endothermic reactions increase in the reverse order. But, the enthalpy values for the exothermic reactions decrease in the order of petroleum cokes, activated carbon, artificial graphite in sol-gel methods.

  • PDF

A Fixed Grid Finite Volume Analysis of Multi-Dimensional Freeze Drying Process under Vacuum Condition (고정격자계에서 유한체적법을 이용한 진공동결건조 과정의 열 및 물질전달에 대한 연구)

  • Chi-Sung, Song
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.981-992
    • /
    • 2004
  • Freeze drying under vacuum condition is a complex process that involves simultaneous heat and mass transfer, sublimation of ice, and motion of sublimation front. Proper treatment of the motion of sublimation interface is crucial for an accurate prediction of the freeze drying process. Based on the enthalpy formulation that has been successfully used in liquid/solid phase change problems. a fixed grid method. streamlined for the freeze drying analysis. was developed in this study. The accuracy of the fixed grid method was checked by solving a one-dimensional tray freeze drying and a two-dimensional vial freeze drying problem and then comparing the results with those by the moving grid method. Finally. the freeze drying characteristics of two-dimensional slab and axis-symmetric cylinder was investigated using the fixed grid method.

Simplified Technique for 3-Dimensional Core T/H Model in CANDU6 Transient Simulation

  • Lim, J.C.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.113-116
    • /
    • 1995
  • Simplified approach has been adopted for the prediction of the thermal behavior of CANDU reactor core during power transients. Based on the assumption that the ratio of mass flow rate for each core channel does not vary during the transient, quasy-steady state analysis technique is applied with predicted core inlet boundary conditions(total mass flow rate and specific enthalpy). For restricted transient case, the presented method shows functionally reasonable estimation of core thermal behavior which could be implemented in the fast running reactor simulation program.

  • PDF

CONSERVATIVE FINITE VOLUME METHOD ON BOUNDARY TREATMENTS FOR FLOW NETWORK SYSTEM ANALYSES (유동망 시스템 해석을 위한 경계처리에 대한 보존형 유한체적법)

  • Hong, S.W.;Kim, C.
    • Journal of computational fluids engineering
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2009
  • To adequately analyze flows in pipe or duct network system, traditional node-based junction coupling methods require the junction loss which is specified by empirical or analytic correlations. In this paper, a new finite volume junction coupling method using a ghost junction cell is developed by considering the interchange of linear momentum as well as the important wall-effect at junction without requiring any correlation on the junction loss. Also, boundary treatment is modified to preserve the stagnation enthalpy across boundaries, such as pipe-end and the interface between junction and branch. Also, the computational accuracy and efficiency of the Godunov-type finite volume schemes are investigated by tracing the total mechanical energy of rapid transients due to sudden closure of valve at downstream end.

A Numerical Analysis of High Speed Flow over Blunt Body Using Upwind Navier-Stokes Method (Upwind Navier-Stokes 방정식을 이용한 무딘 물체 주위의 유동장 해석)

  • Kwon C. O.;Kim S. D.;Song D. J.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.123-141
    • /
    • 1996
  • In this paper the upwind flux difference splitting Navier-Stokes method has been applied to study the perfect gas and the equilibrium chemically reacting hypersonic flow over an axisymmetric sphere-cone(5°) geometry. The effective gamma(γ), enthalpy to internal energy ratio was used to couple chemistry with the fluid mechanics for equilibrium chemically reacting air. The test case condition was at altitude(30km) and Mach number(15). The equilibrium shock thickness over the blunt body region was much thinner than that of perfect gas shock. The pressure difference between perfect gas and equilibrium gas was about 3 ∼ 5 percent. The heat transfer coefficient were also calculated. The results were compared with VSL results in order to validate the current numerical analysis. The results from current method were compared well VSL results ; however, not well at near nose. The proper boundary condition and grid system will be studied to improve the solution quality.

  • PDF