• 제목/요약/키워드: Enhanced CT

검색결과 318건 처리시간 0.034초

Development and Validation of a Simple Index Based on Non-Enhanced CT and Clinical Factors for Prediction of Non-Alcoholic Fatty Liver Disease

  • Yura Ahn;Sung-Cheol Yun;Seung Soo Lee;Jung Hee Son;Sora Jo;Jieun Byun;Yu Sub Sung;Ho Sung Kim;Eun Sil Yu
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.413-421
    • /
    • 2020
  • Objective: A widely applicable, non-invasive screening method for non-alcoholic fatty liver disease (NAFLD) is needed. We aimed to develop and validate an index combining computed tomography (CT) and routine clinical data for screening for NAFLD in a large cohort of adults with pathologically proven NAFLD. Materials and Methods: This retrospective study included 2218 living liver donors who had undergone liver biopsy and CT within a span of 3 days. Donors were randomized 2:1 into development and test cohorts. CTL-S was measured by subtracting splenic attenuation from hepatic attenuation on non-enhanced CT. Multivariable logistic regression analysis of the development cohort was utilized to develop a clinical-CT index predicting pathologically proven NAFLD. The diagnostic performance was evaluated by analyzing the areas under the receiver operating characteristic curve (AUC). The cutoffs for the clinical-CT index were determined for 90% sensitivity and 90% specificity in the development cohort, and their diagnostic performance was evaluated in the test cohort. Results: The clinical-CT index included CTL-S, body mass index, and aspartate transaminase and triglyceride concentrations. In the test cohort, the clinical-CT index (AUC, 0.81) outperformed CTL-S (0.74; p < 0.001) and clinical indices (0.73-0.75; p < 0.001) in diagnosing NAFLD. A cutoff of ≥ 46 had a sensitivity of 89% and a specificity of 41%, whereas a cutoff of ≥ 56.5 had a sensitivity of 57% and a specificity of 89%. Conclusion: The clinical-CT index is more accurate than CTL-S and clinical indices alone for the diagnosis of NAFLD and may be clinically useful in screening for NAFLD.

개의 실험적 급성 괴사성 췌장염 평가에서 Balthazar Computed Tomographic Severity Index의 적용 (Balthazar Computed Tomographic Severity Index Application for Experimental Acute Necrotizing Pancreatitis in Dogs)

  • 최지혜;최민철;윤정희
    • 한국임상수의학회지
    • /
    • 제27권6호
    • /
    • pp.686-692
    • /
    • 2010
  • 컴퓨터 단층촬영술(computed tomography; CT)은 인의에서 췌장염의 진단 기준으로 이용되고 있으며, Balthazar CT severity index (CTSI)는 CT 영상을 바탕으로 췌장 괴사 부위를 측정하여 췌장염의 심각도를 평가하는 지수이다. 본 연구에서는, 25마리의 비글견을 정상 그룹과 대조군, 자가 담즙 주입을 통해 급성 괴사성 췌장염을 유발한 실험군으로 나누어 Balthazar CTSI 측정 결과와 조직 검사 결과를 비교하였다. 정상 개의 췌장의 Hounsfield unit (HU)은 $52.44{\pm}4.58$ 이었고, 급성 괴사성 췌장염에서는 유의적으로 감소하였다(P < .05). 조영 증강 CT 영상에서 확인한 췌장 실질의 괴사 부위를 찾아 Balthazar CTSI를 계산한 결과 조직 검사 결과와 밀접한 상관 관계를 보였으며, 민감도 100%, 특이도 88.89%로 확인되었다. Balthazar CTSI는 급성 췌장염이 발생한 개에서 심각도 평가에 유용한 방법으로 판단된다.

머천다이징 교과과정에서 인터넷을 기반으로한 학습테크롤로지에 대한 대학생들의 시각에 관한 연구 (A Study of Student Perspectives on Web-Based Learning Technology in Merchandising Courses)

  • 이규혜
    • 한국의류학회지
    • /
    • 제30권12호
    • /
    • pp.1788-1799
    • /
    • 2006
  • 본 연구에서는 머천다이징 프로그램에서 인터넷을 기반으로한 학습시스템(e학습시스템)인 WebCT를 의류학과내의 머천다이징 교과과정에서 운영하였을때 학생들이 경험한 여러가지 시각에 대하여 알아보았다. 연구는 온라인 병행강의 혹은 온라인 강의가 시도된 바 없는 한 미국대학에서 WebCT를 처음 도입한 후 2년의 기간 동안 학생들이 시스템에 대하여 느끼는 편의성과 유용성 그리고 선호도와 만족도가 어떻게 바뀌어나가는지 통시적으로 알아보았으며 이러한 경향이 수강학생들의 학점에 미치는 영향을 알아 보았다 2년 동안 매학기 평균 1.5개 정도의 WebCT운영강의에 노출된 학생들이 매 학기말마다 WebCT의 편의성, 유용성 그리고 선호도와 만족도를 묻는 설문에 응하였으며 각 학생들의 최종성적이 함께 데이터화 되어 분석되었다. 분석결과 인터넷이나 컴퓨터사용여부는 더이상 e학습시스템의 걸림돌이 되지 않는 것으로 나타났으며 학생들은 시스템을 무시하거나 과도하게 사용하지 않고 전반적으로 매우 효율적으로 사용하고 있었다. 학생들은 4년간의 대학생활 중 일찍 WebCT에 노출될수록, 한꺼번에 여러과목의 WebCT과목을 들을수록, WebCT수업을 경험할수록 그리고 여학생일수록 WebCT가 유용하다고 지각하고 있었으며 선호도와 만족도가 높은 것으로 나탔다. 한편 WebCT에 대한 선호도와 만족도는 한학기 동안 수강 후 학생들의 성적에 유의한 영향을 주는 것으로 분석되었다.

Exosomes from CIITA-Transfected CT26 Cells Enhance Anti-tumor Effects

  • Fan, Wen;Tian, Xing-De;Huang, E.;Zhang, Jia-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.987-991
    • /
    • 2013
  • Aim: To study anti-tumor effects of exosomes from class II transactivator (CIITA) gene transfected CT26 cells. Methods: In this study, we established an MHC class II molecule-expressing murine colon cancer cell line (CT26-CIITA) by transduction of the CIITA gene. Immune effects in vitro and tumor protective results in vivo were tested and monitored. Results: Exosomes from CT26-CIITA cells were found to contain a high level of MHC class II protein. When loaded on dendritic cells (DCs), exosomes from CT26-CIITA cells significantly increased expression of MHC class II molecules, CD86 and CD80, as compared to exosomes from CT26 cells. In vitro assays using co-culture of immunized splenocytes and exosome-loaded DCs demonstrated that CIITA-Exo enhanced splenocyte proliferation and IFN-${\gamma}$ production of CD4+T cells, while inhibiting IL-10 secretion. In addition, compared to exosomes from CT26 cells, CT26-CIITA-derived exosomes induced higher TNF-${\alpha}$ and IL-12 mRNA levels. A mouse tumour preventive model showed that CT26-CIITA derived exosomes significantly inhibited tumour growth in a dose-dependent manner and significantly prolonged the survival time of tumour-bearing mice. Conclusion: Our findings indicate that CT26-CIITA-released exosomes are more efficient to induce anti-tumour immune responses, suggesting a potential role of MHC class II-containing tumour exosomes as cancer vaccine candidates.

네거티브 경구 조영제를 이용한 PET/CT 촬영시 나타난 종양성 섭취와 유사한 생리적 장관 섭취 (Colon Cancer Mimicking Physiologic FDG Uptake : with Using of Negative Oral Contrast)

  • 정영진;강도영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권3호
    • /
    • pp.186-187
    • /
    • 2006
  • A 64-year-old female with glioblastoma multiforme (GBM) was assigned to our department for whole body PET/CT scan. She ingested 1 liter of pure water as negative oral contrast just before PET/CT examination. FDG-PET/CT images showed a very intense hypermetabolic, focal lesion in the abdominal cavity around descending colon. The SUVmax of the lesion was 17.2. But there was no abnormal lesion corresponded to the area of PET scan in the combined contrast enhanced CT scan. We suggested considering a malignant lesion due to very intense glycolytic activity. Conventional abdominal CT scan & colonoscopy were accomplished within one week after PET/CT evaluation. There was no abnormality in both examinations. We executed follow-up PET/CT evaluation after 1 month and couldn't find any abnormality around the corresponding area. So we concluded the hypermetabolism was colonic physiologic uptake. A colonic physiologic uptake is a well known cause of false positive finding. Nuclear physicians should be considered the possibility of malignancy when interpret focal colonic uptake, especially incidental finding. There are a few reports that using of negative oral contrast is able to reduce gastrointestinal physiologic uptakes. But as we can see in this case, although we used negative oral contrast, intense physiologic uptake is detected and maxSUV is able to up to 17.2. So, it is important to keep a fact in mind. Even though there is a colonic physiologic uptake in PET/CT image, it may be able to show very intense hypermetabolism regardless of using negative oral contrast.

부분 히스토그램 문턱치 알고리즘을 사용한 조영증강 CT영상의 자동 간 분할 (Automatic Liver Segmentation of a Contrast Enhanced CT Image Using a Partial Histogram Threshold Algorithm)

  • Kyung-Sik Seo;Seung-Jin Park;Jong An Park
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권3호
    • /
    • pp.189-194
    • /
    • 2004
  • 조영 증강된 CT 영상의 화소값은 조영제에 의해 이산적으로 변한다. 또한 간의 중간부분에서는 간과 유사한 농도값을 갖는 췌장 때문에 간의 분할이 어렵다. 본 논문에서는 조영증강된 CT영상의 화소값의 이산적인 변화와 간과 겹치는 췌장을 제거하기 위하여 부분 히스토램 문턱치 알고리즘을 사용한 간 분할법을 제안한다. 히스토그램 변환 후 간 구조의 농도 값의 범위를 찾기 위한 적응 다봉성 분할과 췌장 제거를 위한 부분 히스토그램 문턱치 알고리즘을 수행한다. 다음으로, 간 이외의 불필요한 대상을 제거하고 경계를 매끈하게 하기 위해 모폴러지 필터링을 수행한다. 제안된 방법을 평가하기 위해 8명의 환자로부터 획득된 CT 영상중 중간부분에서 4개씩 총 32단면을 선택하였다. 부분 히스토그램 문턱치 알고리즘을 사용한 자동 분할법 II와 수동 분할법의 정규화된 평균 면적의 평균은 0.1671과 0.1711이었으며, 이 두 방법은 아주 적은 차이를 보인다. 또, 자동 분할법 II와 수동 분할법의 평균 면적 오차율은 6.8339 % 이다. 이 실험 결과로부터 제안된 자동 간분할 법은 의사에 의해 시행된 수동 분할법과 매우 유사한 수행능력을 갖는다.

신장동맥 색전술을 실시한 실험적 수신증의 전산화 단층촬영 (Computed tomographic evaluation of experimental hydronephrosis treated with transarterial embolization of renal artery in Beagle dogs)

  • 장동우;윤정희
    • 대한수의학회지
    • /
    • 제41권3호
    • /
    • pp.421-427
    • /
    • 2001
  • 개에서 실험적으로 편측성 신수종증을 유발한 후, 이오헥솔-에탄올 용액을 신장동맥내로 주입하여 신수종증이 유발된 신장으로의 혈류를 차단하는 신동맥 색전술을 실시하고, 선택적 동맥촬영술, 조영증강 전산화 단층촬영, 이용하여 색전술이 실시된 신수종증의 신장과 반대편 정상신장을 평가하고자 본 실험을 실시하였다. 실험적 수신증은 2두의 비글견의 편측 근위 요관을 이중결찰하여 유발하였으며 개에서 요관 결찰 17일째에 편측성 수신증이 유발되었음을 확인할 수 있었다. 신장동맥 색전술은 2두의 신수종증이 유발된 신장측의 신장동맥에 대퇴동맥을 통하여 선택적으로 카테터를 삽입한 후 이오헥솔-에탄올 용액을 주입하였으며, 시술 중 심전도, 산소포화도, 체온, 맥박, 호흡수는 모두 정상범위에 있었다. 신장동맥 색전술 후 사망한 개체는 없었으며, 색전물질의 유출로 인한 부작용도 관찰할 수 없었다. 색전술 직후 그리고 14일째에 실시한 선택적 동맥촬영술을 통하여 색전술을 시행한 2두의 개의 신장동맥에서 재맥관화가 발생하지 않았음을 확인할 수 있었다. 실험군의 2두와 대조군의 1두에서 실시한 전산화단층촬영상에서는 색전술 실시 후 14일째에 실험군과 대조군의 신장의 신우부가 확장되고 확장된 신장에 의해 비장이 복측으로 변위된 것을 확인할 수 있었으며, 색전술 실시 후 두 달째의 소견에서는 색전된 신장의 크기가 감소한 것을 확인할 수 있었다. 조영제 증강 전산화단층촬영에서는 색전술을 실시하지 않은 신장피질의 신호강도가 증가하는 것을 관찰할 수 있었으나, 색전술을 실시한 신장피질의 신호강도는 증가하지 않았다. 따라서, 조영 증강 전산화 단층촬영은 개의 수신증에 실시한 신장동맥 색전술 후의 신장동맥의 재맥관화를 평가할 수 있는 유용한 검사법으로 사료된다.

  • PDF

조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가 (Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography)

  • 권혜미;정태섭;서상현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.41-47
    • /
    • 2011
  • 목적: 조영 증강 삼차원 자기공명혈관촬영술에서 관찰되는 내경정맥 폐쇄의 원인을 조영 증강 전산화단층촬영술을 이용하여 분석하고자 한다. 대상과 방법: 2005년부터 2008년까지 두경부 조영증강 자기공명혈관조영술과 조영증강 전산화단층촬영술을 함께 시행한 30명의 환자를 대상으로 하였다. 조영증강 자기공명혈관조영술에서 내경정맥의 폐쇄가 있는 경우 폐쇄군으로 하였고 내경정맥의 폐쇄가 없는 경우 대조군으로 구분하였다. 다음의 지표를 조영증강 전산화단층촬영술에서 분석하였다 : 1) 내정정맥의 직경; 2) 경상돌기와제일경추의 외측돌기와의 거리; 3) 제일경추의 외측돌기의 최대넓이 이후 각각의 지표를 폐쇄군과 대조군에서 비교하였다. 결과: 폐쇄군에서 내경정맥의 직경 그리고 정상돌기와 제일경추의 외측돌기와의 거리는 각각 $1.6{\pm}1.0\;mm$ 그리고 $4.1{\pm}2.1\;mm$로 평가되었으며 이는 대조군과 비교하여 유의하게 작게 분석되었다 (p < 0.01). 폐쇄군에서 제일경추의 외측돌기의 최대 넓이는 $103.4{\pm}25.3\;mm^2$로 평가되었으며 이는 대조군과 비교하여 유의하게 넓은 것으로 나타났다 (p < 0.05). 결론: 조영증강 자기공명혈관촬영술에서 보이던 대경정맥 폐쇄의 원인은 제일경추의 비대칭적인 큰 넓이에 의한 것 일수 있다.

간 국소 결절성 과형성의 방사선학적 소견 (Focal Nodular Hyperplasia in Liver: A Case Report)

  • 성기호;조재호;장재천
    • Journal of Yeungnam Medical Science
    • /
    • 제12권2호
    • /
    • pp.400-404
    • /
    • 1995
  • 국소 결절성 과형성은 섬유성 격막에 의해 나누어지는 간세포와 Kupffer 세포의 결절로 이루어진 양성 종괴이다. 방사선학적으로 다른 종괴와 유사한 소견을 보이나 그 예후와 치료는 달라 감별이 요구된다. 저자들이 경험한 증례는 조영 후 영상을 조영전기영상과 조영후기영상으로 분리함으로써 종괴의 혈류형태를 관찰할 수 있는 급속조영 CT를 설시하여 감별진단에 도움을 받을 수 있었고 병리조직학적으로 국소 결절성 과형성으로 확인된, 급속조영 CT 설시 후 국내에서 보고되는 최초의 증례이다.

  • PDF