• Title/Summary/Keyword: Enhanced CT

Search Result 322, Processing Time 0.045 seconds

Unusual Presentation of a Rib Osteochondroma as Hard Breast Lump in a Young Male: A Case Report (젊은 남성에서 딱딱한 유방 덩이로 만져진 갈비뼈 골연골종의 드문 증상: 증례 보고)

  • Vendoti Nitheesha Reddy;Krishnan Nagarajan;Vendoti Midhusha Reddy
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.270-274
    • /
    • 2023
  • Osteochondroma arising from the rib is rare. They arise as bony outgrowths from the rib and extend either extrathoracically into the subcutaneous plane or intrathoracically compressing the lung or mediastinal structures. A 23-year-old male patient presented with complaints of breast lump since last year. On clinical examination, a hard bony projection with lobulated contour was palpable. Chest radiograph and contrast-enhanced CT showed a bony outgrowth arising from the anterior aspect of costochondral junction of the right fourth rib with displacement of pectoralis major muscle anteriorly. Osteochondroma should be considered as a differential diagnosis in the presentation of hard lump in the breast along with other chest wall tumors.

Percutaneous Radiofrequency Ablation Guided by Contrast-enhanced Ultrasound in Treatment of Metastatic Hepatocellular Carcinoma after Liver Transplantation

  • Dai, Xin;Zhao, Hong-Qiang;Liu, Run-Hao;Xu, Chang-Tao;Zheng, Fang;Yu, Li-Bao;Li, Wei-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3709-3712
    • /
    • 2012
  • This study evaluated the advantages and applications of contrast-enhanced ultrasound (CEUS)-supported percutaneous radiofrequency ablation (RFA) in the treatment of metastatic hepatocellular carcinoma after liver transplantation, based on clinical details. CEUS-supported percutaneous RFA was adopted to treat 12 patients with hepatic metastatic carcinomas after liver transplantation. The diameters of the metastatic carcinomas varied from 1 cm to 5 cm, and the foci were discovered after 3 months to 12 months. Each focus was diagnosed and localised by CEUS for RFA once or twice. Curative effects were evaluated by CEUS or contrast-enhanced CT after the treatment. The re-examination results at 2 weeks post-treatment showed that the foci of 11 patients were ablated completely, whereas one patient with the largest focus required retreatment by RFA because of a partial residue. No local recurrence was found one month later in the re-examination. CEUS-supported percutaneous RFA in the treatment of hepatic metastatic carcinoma after liver transplantation has the advantages of accurate localisation, good efficacy, easy operation, and minimal invasion without any complications. Therefore, it can be recommended as the preferred therapy for hepatic metastatic carcinoma after liver transplantation.

Differentiation between Clear Cell Sarcoma of the Kidney and Wilms' Tumor with CT

  • Choeum Kang;Hyun Joo Shin;Haesung Yoon;Jung Woo Han;Chuhl Joo Lyu;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1185-1193
    • /
    • 2021
  • Objective: Clear cell sarcoma of the kidney (CCSK) is the second-most common but extremely rare primary renal malignancy in children after Wilms' tumor. The aims of this study were to evaluate the imaging features that could distinguish between CCSK and Wilms' tumor and to assess the features with diagnostic value for identifying CCSK. Materials and Methods: We reviewed the initial contrast-enhanced abdominal-pelvic CT scans of children with CCSK and Wilms' tumor between 2010 to 2019. Fifty-eight children (32 males and 26 females; age, 0.3-10 years), 7 with CCSK, and 51 with Wilms' tumor, were included. The maximum tumor diameter, presence of engorged perinephric vessels, maximum density of the tumor (Tmax) of the enhancing solid portion, paraspinal muscle, contralateral renal vein density, and density ratios (Tmax/muscle and Tmax/vein) were analyzed on the renal parenchymal phase of contrast-enhanced CT. Fisher's exact tests and Mann-Whitney U tests were conducted to analyze the categorical and continuous variables, respectively. Logistic regression and receiver operating characteristic curve analyses were also performed. Results: The age, sex, and tumor diameter did not differ between the two groups. Engorged perinephric vessels were more common in patients in the CCSK group (71% [5/7] vs. 16% [8/51], p = 0.005). Tmax (median, 148.0 vs. 111.0 Hounsfield unit, p = 0.004), Tmax/muscle (median, 2.64 vs. 1.67, p = 0.002), and Tmax/vein (median, 0.94 vs. 0.59, p = 0.002) were higher in the CCSK compared to the Wilms' group. Multiple logistic regression revealed that engorged vessels (odds ratio 13.615; 95% confidence interval [CI], 1.770-104.730) and Tmax/muscle (odds ratio 5.881; 95% CI, 1.337-25.871) were significant predictors of CCSK. The cutoff values of Tmax/muscle (86% sensitivity, 77% specificity) and Tmax/vein (71% sensitivity, 86% specificity) for the diagnosis of CCSK were 1.97 and 0.76, respectively. Conclusion: Perinephric vessel engorgement and greater tumor enhancement (Tmax/muscle > 1.97 or Tmax/vein > 0.76) are helpful for differentiating between CCSK and Wilms' tumor in children aged below 10 years.

Vertebral Venous Congestion That May Mimic Vertebral Metastasis on Contrast-Enhanced Chest Computed Tomography in Chemoport Inserted Patients

  • Jeong In Shin;Choong Guen Chee;Min A Yoon;Hye Won Chung;Min Hee Lee;Sang Hoon Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.62-73
    • /
    • 2024
  • Objective: This study aimed to determine the prevalence of vertebral venous congestion (VVC) in patients with chemoport insertion, evaluate the imaging characteristics of nodular VVC, and identify the factors associated with VVC. Materials and Methods: This retrospective single-center study was based on follow-up contrast-enhanced chest computed tomography (CT) of 1412 adult patients who underwent chemoport insertion between January 2016 and December 2016. The prevalence of venous stenosis, reflux, and VVC were evaluated. The imaging features of nodular VVC, including specific locations within the vertebral body, were analyzed. To identify the factors associated with VVC, patients with VVC were compared with a subset of patients without VVC who had been followed up for > 3 years without developing VVC after chemoport insertion. Toward this, a multivariable logistic regression analysis was performed. Results: After excluding 333 patients, 1079 were analyzed (mean age ± standard deviation, 62.3 ± 11.6 years; 540 females). The prevalence of VVC was 5.8% (63/1079), with all patients (63/63) demonstrating vertebral venous reflux and 67% (42/63) with innominate vein stenosis. The median interval between chemoport insertion and VVC was 515 days (interquartile range, 204-881 days). The prevalence of nodular VVC was 1.5% (16/1079), with a mean size of 5.9 ± 3.1 mm and attenuation of 784 ± 162 HU. Nodular VVC tended to be located subcortically. Forty-four patients with VVC underwent CT examinations with contrast injections in both arms; the VVC disappeared in 70% (31/44) when the contrast was injected in the arm contralateral to the chemoport site. Bevacizumab use was independently associated with VVC (odds ratio, 3.45; P < 0.001). Conclusion: The prevalence of VVC and nodular VVC was low in patients who underwent chemoport insertion. Nodular VVC was always accompanied by vertebral venous reflux and tended to be located subcortically. To avoid VVC, contrast injection in the arm contralateral to the chemoport site is preferred.

Clinical Feasibility of Dual-Layer CT With Virtual Monochromatic Image for Preoperative Staging in Patients With Breast Cancer: A Comparison With Breast MRI

  • Bokdong Yeo;Kyung Min Shin;Byunggeon Park;Hye Jung Kim;Won Hwa Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.9
    • /
    • pp.798-806
    • /
    • 2024
  • Objective: Dual-layer CT (DLCT) can create virtual monochromatic images (VMIs) at various monochromatic X-ray energies, particularly at low keV levels, with high contrast-to-noise ratio. The purpose of this study was to assess the clinical feasibility of contrast-enhanced chest DLCT with a low keV VMI for preoperative breast cancer staging, in comparison to breast MRI. Materials and Methods: A total of 152 patients with 155 index breast cancers were enrolled in the study. VMIs were generated from contrast-enhanced chest DLCT at 40 keV and maximum intensity projection (MIP) with three-dimensional (3D) reconstruction was performed for both bilateral breast areas. Two radiologists reviewed in consensus the 3D MIP images of the chest DLCT with VMI and breast MRI in separate sessions with a 3-month wash-out period. The detection rate and mean tumor size of the index cancer were compared between the chest DLCT with VMI and breast MRI. Additionally, the agreement of tumor size measurement between the two imaging modalities were evaluated. Results: Of all index cancers, 84.5% (131/155) were detected in the chest DLCT with VMI, while 88.4% (137/155) were detected in the breast MRI (P = 0.210). The Bland-Altman agreement between the chest DLCT with VMI and breast MRI was a mean difference of -0.05 cm with 95% limits of agreement of -1.29 to 1.19 cm. The tumor size in the chest DLCT with VMI (2.3 ± 1.7 cm) was not significantly different from that in the breast MRI (2.4 ± 1.6 cm) (P = 0.106). Conclusion: The feasibility of chest DLCT with VMI was demonstrated for preoperative tumor staging in breast cancer patients, showing comparable cancer detectability and good agreement in tumor size measurement compared to breast MRI. This suggests that chest DLCT with VMI can serve as a potential alternative for patients who have contraindications to breast MRI.

Effects of the Operating Conditions on the Performance of Direct Methanol Fuel Cells (직접메탄올 연료전지의 운전 조건이 성능에 미치는 영향)

  • Han, Chang-Hwa;Kim, Nam-Hoon;Lee, Joong-Hee
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.3
    • /
    • pp.292-298
    • /
    • 2011
  • This study examines the effects of the ambient temperature (AT), methanol feeding temperature (MFT), methanol concentration (MC) and methanol flow rate (MFR) on the performance and cell temperature (CT) of a 5-stacked direct methanol fuel cell (DMFC). The AT, MFT, MC, and MFR are varied from $-10^{\circ}C$ to $+40^{\circ}C$, $50^{\circ}C$ to $90^{\circ}C$, 0.5M to 3.0M and 11.7 mL $min^{-1}$ to 46.8 mL $min^{-1}$, respectively. The performance of the DMFC under various operating conditions is analyzed from the I-V polarization curve, and the methanol crossover is estimated by gas chromatography (GC). The performance of the DMFC improves significantly with increasing AT. The open circuit voltage (OCV) decreases with increasing MC due to the enhanced likelihood of methanol crossover. The cell performance is improved significantly when the MFR is increased from 11.7 mL $min^{-1}$ to 28.08 mL $min^{-1}$. The change in cell performance is marginal with further increases in MFR. The CT increases significantly with increasing AT. The effect of the MFT and MFR is moderate, and the effect of MC is marginal on the CT of the DMFC.

Diagnostic Imaging of Isolated Splenic Torsion in a German Shepherd Dog (독일셰퍼드 견에서 단독으로 발생한 비장 염전의 영상진단)

  • Lee, Ki-Ja;Jeong, Seong-Mok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.613-616
    • /
    • 2011
  • A 5-year-old male German shepherd dog was presented with a 4 day-history of anorexia and depression. Abdominal radiographs showed a large soft tissue mass and loss of serosal detail. Ultrasonographs revealed splenomegaly with the lacy pattern parenchyma, perivenous hyperechoic region at the splenic hilum, and loss of splenic venous flow. Computed tomographic findings included the enlarged non-enhanced spleen except perivenous region at the splenic hilum and a whirled soft tissue mass at the splenic hilum. Exploratory laparotomy confirmed the diagnosis of splenic torsion. Ultrasonographic findings including lacy appearance, hyperechoic perivenous echogenicity and absence of splenic blood flow and CT findings including no or minimal enhancement of the spleen and a whirled appearance of splenic pedicle could be useful for diagnosing isolated splenic torsion in the dog.

A Case of Rasmussen Aneurysm Treated by Pulmonary Arterial Embolization (폐동맥색전술로 치료된 Rasmussen 동맥류 1예)

  • Park, Sung-Oh;Ko, Hyuk;Kim, Su-Hee;Park, Wan;Lee, Deck-Hee;Ryul, Dae-Sik;Jung, Bock-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • A 42 year-old male with a history of multidrug-resistant pulmonary tuberculosis suddenly developed massive hemoptysis. Embolization of a bronchial artery branch and the collateral systemic arteries did not resolve the recurrent bleeding. Spiral computerized tomography(spiral CT) of the chest showed contrast enhanced nodules within a large cavity at the left lower lobe in the arterial phase suggesting a Rasmussen aneurysm. A pulmonary angiogram showed abnormal vascular nodules at that site. Coils were deployed at both the proximal and distal vessels of this aneurysmal sac for embolization. Transcatheter arterial embolization is a safe and effective means of controlling bleeding from this pulmonary arterial pseudoaneurysm. Here we report a case of a Rasmussen aneurysm diagnosed by spiral CT, which was successfully treated by pulmonary arterial embolization with a coil.

  • PDF

Analysis of Image Quality and Optimized Reconstruction Window through Heart Rate and Its Variation in Retrospectively ECG-gated Coronary Angiography Using Multi-Detector Row CT

  • Lee, Sang-Ho;Park, Byoung-Wook;Kim, Hee-Joung;Haijo Jung;Kang, Won-suk;Son, Hye-Kyung;Choe, Kyu-Ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.461-463
    • /
    • 2002
  • Image quality and selection of optimized window for good quality reconstruction in coronary angiography using multi-detector row CT (MDCT) have not been studied by heart rate and its variation. Therefore, the effect of heart rate and its variation was systemically analyzed. Eighty-three patients were undergone contrast-enhanced coronary angiography using MDCT. In this study, sixty cases were enrolled. Two radiologists graded image quality as follows: 4, excellent; 3, good; 2, fair; l, bad. The starting points of the reconstruction window were chosen at seventy and forty percent of R wave interval. Optimized window was scored as 1 when 40% reconstruction was better quality than 70%, as 2 when 40% reconstruction is same as 70%, and as 3 when 70% reconstruction was better than 40%. Regression analysis was performed. The range of variation of beats per minute (BPM) was well correlated with image quality (r=-0.55, p=0.000), however correlation with optimized window percentage was not statistically significant (p=0.969). By contraries, median value of BPM was comparatively well correlated with optimized window grade (r=-0.24, p=0.086). Median value of BPM was not well correlated with image quality (r=0.l70, p=0.l97). Image quality is more affected by variation of heart rate (VHR) than by higher heart rate. Selection of optimized reconstruction window for good image quality is mainly affected by heart rate and there is a tendency that systolic phase reconstruction is better in image quality than diastolic reconstruction in higher heart rate.

  • PDF

Leak Sign on Dynamic-Susceptibility-Contrast Magnetic Resonance Imaging in Acute Intracerebral Hemorrhage

  • Park, Ji Kang;Hong, Dae Young;Jin, Sun Tak;Lee, Dong-Woo;Pyun, Hae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: A CT angiography spot sign (CTA-spot) is a significant predictor of the early expansion of an intracerebral hemorrhage (ICH-Ex). Dynamic-susceptibility-contrast magnetic resonance imaging (DSC-MRI) can track the real-time leaking of contrast agents. It may be able to indicate active bleeding, like a CTA-spot. Materials and Methods: From September 2014 to February 2017, we did non-contrast CT, CTA, and DSC-MRI examinations of seven patients with acute ICH. We investigated the time from symptom onset to the first contrast-enhanced imaging. We evaluated the time course of the contrast leak within the ICH at the source image of the DSC-MRI and the volume change of ICH between non-contrast CT and DSC-MRI. We compared the number of slices showing CTA-spots and DSC-MRI leaks. Results: The CTA-spot and DSC-MRI leak-sign were present in four patients, and two patients among those showed ICH-Ex. The time from the symptom onset to CTA or DSC-MRI was shorter for those with a DSC-MRI leak or CTA-spot than for three patients without either (70-130 minutes vs. 135-270 minutes). The leak-sign began earlier, lasted longer, and spread to more slices in the patients with ICH-Ex than in those without ICH-Ex. The number of slices of the DSC-MRI leak and the number of the CTA-spot were well correlated. Conclusion: DSC-MRI can demonstrate the leakage of GBCA within hyperacute ICH, showing the good contrast between hematoma and contrast. The DSC-MRI leakage sign could be related to the hematoma expansion in patients with ICH.