• 제목/요약/키워드: Engineered nanoparticle

검색결과 14건 처리시간 0.025초

Comparison of Real Time Nanoparticle Monitoring Instruments in the Workplaces

  • Ham, Seunghon;Lee, Naroo;Eom, Igchun;Lee, Byoungcheun;Tsai, Perng-Jy;Lee, Kiyoung;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • 제7권4호
    • /
    • pp.381-388
    • /
    • 2016
  • Background: Relationships among portable scanning mobility particle sizer (P-SMPS), condensation particle counter (CPC), and surface area monitor (SAM), which are different metric measurement devices, were investigated, and two widely used research grade (RG)-SMPSs were compared to harmonize the measurement protocols. Methods: Pearson correlation analysis was performed to compare the relation between P-SMPS, CPC, and SAM and two common RG-SMPS. Results: For laboratory and engineered nanoparticle (ENP) workplaces, correlation among devices showed good relationships. Correlation among devices was fair in unintended nanoparticle (UNP)-emitting workplaces. This is partly explained by the fact that shape of particles was not spherical, although calibration of sampling instruments was performed using spherical particles and the concentration was very high at the UNP workplaces to allow them to aggregate more easily. Chain-like particles were found by scanning electron microscope in UNP workplaces. The CPC or SAM could be used as an alternative instrument instead of SMPS at the ENP-handling workplaces. At the UNP workplaces, where concentration is high, real-time instruments should be used with caution. There are significant differences between the two SMPSs tested. TSI SMPS showed about 20% higher concentration than the Grimm SMPS in all workplaces. Conclusions: For nanoparticle measurement, CPC and SAM might be useful to find source of emission at laboratory and ENP workplaces instead of P-SMPS in the first stage. An SMPS is required to measure with high accuracy. Caution is necessary when comparing data from different nanoparticle measurement devices and RG-SMPSs.

나노 입자에 의한 미생물 불활성화 특성 및 메카니즘 (Antimicrobial Activity and Mechanism of Various Nanoparticles)

  • 김지연;박희진;윤제용
    • 공업화학
    • /
    • 제21권4호
    • /
    • pp.366-371
    • /
    • 2010
  • 환경 나노 기술의 빠른 발전과 함께 다양한 종류의 나노 입자에 의한 미생물 불활성화 성능이 주목 받아 왔으며, 이러한 특성을 적용한 제품들이 연구개발되어 왔다. 하지만 최근 나노 입자가 갖는 탁월한 생물학적 특성이 환경에 유익한 미생물뿐만 아니라 인간에게까지 유해한 영향을 줄 수 있다는 독성 연구 결과가 발표됨에 따라, 관련 연구자 및 일반 시민들에게 우려와 논쟁을 가져오고 있다. 본 총설에서는 이러한 나노 물질의 양면성에 대한 정확한 이해를 돕고자 기존의 연구를 중심으로 다양한 나노 입자에 의한 미생물 불활성화 특성과 메카니즘 및 응용 분야에 대해서 검토, 정리하였다.

Nanometrology and its perspectives in environmental research

  • Kim, Hyun-A;Seo, Jung-Kwan;Kim, Taksoo;Lee, Byung-Tae
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.16.1-16.9
    • /
    • 2014
  • Objectives Rapid increase in engineered nanoparticles (ENPs) in many goods has raised significant concern about their environmental safety. Proper methodologies are therefore needed to conduct toxicity and exposure assessment of nanoparticles in the environment. This study reviews several analytical techniques for nanoparticles and summarizes their principles, advantages and disadvantages, reviews the state of the art, and offers the perspectives of nanometrology in relation to ENP studies. Methods Nanometrology is divided into five techniques with regard to the instrumental principle: microscopy, light scattering, spectroscopy, separation, and single particle inductively coupled plasma-mass spectrometry. Results Each analytical method has its own drawbacks, such as detection limit, ability to quantify or qualify ENPs, and matrix effects. More than two different analytical methods should be used to better characterize ENPs. Conclusions In characterizing ENPs, the researchers should understand the nanometrology and its demerits, as well as its merits, to properly interpret their experimental results. Challenges lie in the nanometrology and pretreatment of ENPs from various matrices; in the extraction without dissolution or aggregation, and concentration of ENPs to satisfy the instrumental detection limit.

탄소나노튜브 표면 처리 실험실 종사자의 공기중 나노입자 노출에 관한 연구 (Exposure of Laboratory Workers to Airborne Nanoparticles during Acid Treatments on Engineered Carbon Nanotubes)

  • 하주현;신용철;이승철;;김부욱;최병순;강동묵;백남원
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.343-350
    • /
    • 2010
  • This study was performed to investigate laboratory workers' exposures to airborne nanoparticles at a university laboratory where acid treatment experiments were conducted on the surfaces of engineered carbon nanotubes (CNTs). The surface area concentrations, number concentrations, and mass concentrations of airborne nanoparticles were measured at personal breathing zones (PBZs) for various tasks using direct reading instruments. For all three metrics, airborne nanoparticle concentrations during the experiments were higher than background levels measured before and after the experiments for all three metrics. Among the various tasks that were performed as part of these experiments, one task that involved filtering a mixture of acid and CNTs showed the highest concentrations in all three metrics, with concentrations of $116.6\;{\mu}m^2$/cc, 24320 pt/cc, and $9.0\;{\mu}g/m^3$, respectively. Nanoparticle surface area concentrations measured at a representative area fluctuated with those at the PBZs in the laboratory. This result indicates that nanoparticles generated during the experiments were not just limited to the PBZs of the workers but were also present throughout the room, potentially exposing co-located workers. CNTs were detected by a transmission electron microscope in an air sample collected while handling the CNTs. All the tasks were performed inside fume hoods, with the sliding sashes open to their required heights. It was noted that the capture velocities of the fume hoods were much lower than the American National Standards Institute (ANSI)'s recommendation level (0.4 to 0.6 m/s). In conclusion, this study showed that, due to inadequate control, laboratory researchers performing acid treatment experiments on surfaces of CNTs were exposed to airborne nanoparticles generated during the tasks.

Identifying and quantitating defects on chemical vapor deposition grown graphene layers by selected electrochemical deposition of Au nanoparticles

  • So, Hye-Mi;Mun, Jeong-Hun;Bang, Gyeong-Sook;Kim, Taek-Yong;Cho, Byung-Jin;Ahn, Chi-Won
    • Carbon letters
    • /
    • 제13권1호
    • /
    • pp.56-59
    • /
    • 2012
  • The defect sites on chemical vapor deposition grown graphene are investigated through the selective electrochemical deposition (SED) of Au nanoparticles. For SED of Au nanoparticles, an engineered potential pulse is applied to the working electrode versus the reference electrode, thereby highlighting the defect sites, which are more reactive relative to the pristine surface. Most defect sites decorated by Au nanoparticles are situated along the Cu grain boundaries, implying that the origin of the defects lies in the synthesis of uneven graphene layers on the rough Cu surface.

Nanowire Patterning for Biomedical Applications

  • Yun, Young-Sik;Lee, Jun-Young;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.382-382
    • /
    • 2012
  • Nanostructures have a larger surface/volume ratio as well as unique mechanical, physical, chemical properties compared to existing bulk materials. Materials for biomedical implants require a good biocompatibility to provide a rapid recovery following surgical procedure and a stabilization of the region where the implants have been inserted. The biocompatibility is evaluated by the degree of the interaction between the implant materials and the cells around the implants. Recent researches on this topic focus on utilizing the characteristics of the nanostructures to improve the biocompatibility. Several studies suggest that the degree of the interaction is varied by the relative size of the nanostructures and cells, and the morphology of the surface of the implant [1, 2]. In this paper, we fabricate the nanowires on the Ti substrate for better biocompatible implants and other biomedical applications such as artificial internal organ, tissue engineered biomaterials, or implantable nano-medical devices. Nanowires are fabricated with two methods: first, nanowire arrays are patterned on the surface using e-beam lithography. Then, the nanowires are further defined with deep reactive ion etching (RIE). The other method is self-assembly based on vapor-liquid-solid (VLS) mechanism using Sn as metal-catalyst. Sn nanoparticle solutions are used in various concentrations to fabricate the nanowires with different pitches. Fabricated nanowries are characterized using scanning electron microscopy (SEM), x-ray diffraction (XRD), and high resolution transmission electron microscopy (TEM). Tthe biocompatibility of the nanowires will further be investigated.

  • PDF

The Role of Surface Oxide of Metal Nanoparticles on Catalytic Activity of CO Oxidation Unraveled with Ambient Pressure X-ray Photoelectron Spectroscopy

  • Park, Jeong Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.132-132
    • /
    • 2013
  • Colloidal synthesis of nanoparticles with well-controlled size, shape, and composition, together with development of in situ surface science characterization tools, such as ambient pressure X-ray photoelectron spectroscopy (APXPS), has brought new opportunities to unravel the surface structure of working catalysts. Recent studies suggest that surface oxides on transition metal nanoparticles play an important role in determining the catalytic activity of CO oxidation. In this talk, I will outline the recent studies on the influence of surface oxides on Rh, Pt, Ru and Co nanoparticles on the catalytic activity of CO oxidation [1-3]. Transition metal nanoparticle model catalysts were synthesized in the presence of poly(vinyl pyrrolidone) polymer capping agent and deposited onto a flat Si support as two-dimensional arrays using the Langmuir-Blodgett deposition technique. APXPS studies exhibited the reversible formation of surface oxides during oxidizing, reducing, and CO oxidation reaction [4]. General trend is that the smaller nanoparticles exhibit the thicker surface oxides, while the bigger ones have the thin oxide layers. Combined with the nature of surface oxides, this trend leads to the different size dependences of catalytic activity. Such in situ observations of metal nanoparticles are useful in identifying the active state of the catalysts during use and, hence, may allow for rational catalyst designs for practical applications. I will also show that the surface oxide can be engineered by using the simple surface treatment such as UV-ozone techniques, which results in changing the catalytic activity [5]. The results suggest an intriguing way to tune catalytic activity via engineering of the nanoscale surface oxide.

  • PDF

Nanoparticle Induced Oxidative Stress in Cancer Cells: Adding New Pieces to an Incomplete Jigsaw Puzzle

  • Nogueira, Daniele Rubert;Rolim, Clarice M. Bueno;Farooqi, Ammad Ahmad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권12호
    • /
    • pp.4739-4743
    • /
    • 2014
  • Nanotechnology is an emerging field with many promising applications in drug delivery systems. Because of outstanding developments in this field, rapidly increasing research is directed to the development of nanocarriers that may enhance the availability of drugs to the target sites. Substantial fraction of information has been added into the existing scientific literature focusing on the fact that nanoparticles usually generate reactive oxygen species to a greater extent than micro-sized particles. It is worth mentioning that oxidative stress regulates an array of cell signaling cascades that resulted in cancer cell damage. Accumulating experimental evidence over the years has shown that wide-ranging biological mechanisms are triggered by these NPs in cultured cells due to the unique properties of engineered nanoparticles. In this review, we have attempted to provide an overview of the signaling cascades that are activated by oxidative stress in cancer cells in response to different kinds of nanomaterials, including quantum dots, metallic and polymeric nanoparticles.

전하가 다른 PLGA 나노 입자의 생체 안정성 및 암세포에 미치는 영향 (The Biostability and Cancer Effect of PLGA Nanoparticles with Different Charges)

  • 김인우;박승빈;지유현;박상효;기재홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.140-145
    • /
    • 2018
  • Cancer is a major burden of human disease worldwide. Current chemotherapy has severe side effects because the drugs affect whole body nonspecifically. In addition, the drugs to reach cancer cells are very limited. Over the last two decades, Drug Delivery System (DDS) using nanoparticles has suggested promising results to improve current limitations. In this study, we prepared PLGA nanoparticles with different charge properties and observed their stability and internalization effect to cancer cells. Results using Dynamic Light Scattering (DLS) and Fourier Transform Infrared Spectroscopy (FTIR) confirmed the size and chemical composition of the nanoparticles. The stability of the nanoparticles in pH buffers were variable depending on charge properties. The nanoparticles showed different cytotoxicity and internalization effects to MCF-7 human breast cancer cells. In conclusion, we demonstrated the importance of delicately engineered nanoparticles for better DDS in cancer.