• Title/Summary/Keyword: Engine Coupler

Search Result 6, Processing Time 0.018 seconds

A study on the way to improve abnormal noise by applying vehicle fitting type generator (탑재형 발전기 적용에 따른 이상소음 개선 방안에 관한 연구)

  • Kim, Seon-Jin;Kim, Sung-Gon;Yun, Seong-Ho;Shin, Cheol-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.266-274
    • /
    • 2020
  • This paper reports a means of improving the abnormal noise of light tactical vehicles (LTVs) by applying a vehicle fitting type generator (hereinafter called generator). LTVs are classified as having generators, and there are no differences in the noise level. On the other hand, quality improvement was performed in response to unpleasant noise felt by the user (hereinafter called abnormal noise) during vehicle operation. To improve the quality, the generator mounting structure and the phenomenon of the vehicle in the problem were identified. Through this, it was confirmed that the noise caused by the generator installation was the rattle noise. Rattle noise at the engine driving system is normally caused by the transfer of irregular torque generated by the engine power stroke and the backlash by the spline-serration fitting structure between the engine coupler and rotor assembly in a generator. Therefore, this study established an improvement plan to apply a damper coupler to solve the cause of the abnormal noise. Regarding the improved establishment method, the improvement effect was confirmed from the influence of the irregular torque of the engine, noise level, dynamic characteristics analysis, and the endurance test of the parts.

A Study on the Corrosion Prevention of the Integral Series Generator for Military Vehicles (군용차량용 엔진일체형 직렬 발전기 부식 방지에 관한 연구)

  • Kang, Tae-Woo;Kim, Seong-Gon;Shin, Cheol-Ho;Lee, Kye-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.74-79
    • /
    • 2019
  • The military vehicle produces electric power through an engine-integrated serial hybrid generator that is connected to the engine and does not have a separate generator installation space. However, depending on the mechanical characteristics of the connection between the generator and the engine, iron oxide for internal rusting and lubrication grew scattered. The iron oxide is adhered to the starter to deteriorate the starting performance, and there is a problem that the noise of the leg due to wear of the gear is increased. To solve this problem, the connection spline material and the surface treatment of the engine were improved and the shape was changed to a grease sealing type to prevent the generation of iron oxide inside. As the shape of the generator connector composing the shafting system was changed, the integrity of the structure was confirmed through the torsional endurance test. In addition, through the actual vehicle load test, it was verified that no corrosion occurred during the target life span without internal corrosion. It was confirmed that the anti-scattering structure of the grease effectively suppresses the generation of iron oxide, thereby reducing the noise generated from the generator. In this paper, we propose a fundamental solution to the degradation of the starter and the noise generation by preventing the back corrosion caused by the serial hybrid generator installed between the engine and the transmission.

Improvement of Transient Characteristics of Brush-less Type Synchronous Generator for Emergency Driven by Internal-Combustion Engine (내연기관 구동 비상용 브러시리스형 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.268-272
    • /
    • 2016
  • A brush-less type synchronous generator is driven by an internal-combustion engine that is used for emergency source. This kind of generator has to maintain output voltage in a range of some degree under the abrupt load irregular conditions such as a full load trip. This paper suggests a suppression method of increasing the output voltage over the rating. Automatic voltage regulator detects excessive rising of output voltage of the generator and supplies the signals to a switch installed in the rotating exciter through the photo-coupler. The current of main field rapidly decreases by additional resistor of the main filed circuit. Therefore, the output voltage of the generator is maintained effectively. The experimental results verified that the excessive value of the output voltage is limited in the range of 7% of the rated voltage.

Development of real-time monitoring system using wired and wireless networks ina full-scale ship

  • Paik, Bu-Geun;Cho, Seong-Rak;Park, Beom-Jin;Lee, Dong-Kon;Bae, Byung-Dueg
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.2 no.3
    • /
    • pp.132-138
    • /
    • 2010
  • In the present study, the real-time monitoring system is developed based on the wireless sensor network (WSN) and power line communication (PLC) employed in the 3,000-ton-class training ship. The WSN consists of sensor nodes, router, gateway and middleware. The PLC is composed of power lines, modems, Ethernet gateway and phase-coupler. The basic tests show that the ship has rather good environments for the wired and wireless communications. The developed real-time monitoring system is applied to recognize the thermal environments of main-engine room and one cabin in the ship. The main-engine room has lots of heat sources and needs careful monitoring to satisfy safe operation condition or detect any human errors beforehand. The monitoring is performed in two regions near the turbocharger and cascade tank, considered as heat sources. The cabin on the second deck is selected to monitor the thermal environments because it is close to the heat source of main engine. The monitoring results of the cabin show the thermal environment is varied by the human activity. The real-time monitoring for the thermal environment would be useful for the planning of the ventilation strategy based on the traces of the human activity against inconvenient thermal environments as well as the recognizing the temperature itself in each cabin.

The Design of a I/O Interface Circuits for the Signal Driver of the Engine Control Relays and the Output Signal Monitoring of Diesel Generator (디젤 발전기 출력 신호의 모니터링 및 엔진제어 릴레이 구동을 위한 입출력 인터페이스 회로 설계)

  • Joo, Jae-hun;Kim, Jin-ae;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.547-550
    • /
    • 2009
  • This paper presents a digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for Emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes pick-up coil signal.

  • PDF

The Design of a I/O Circuits for Driving and Monitoring of the Diesel Generator for Emergency (비상용 디젤 발전기 구동 및 모니터링을 위한 입출력 회로 설계)

  • Joo, Jae-Hun;Kim, Jin-Ae;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1491-1496
    • /
    • 2009
  • This paper presents an digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes rick-up coil signal.