• Title/Summary/Keyword: Energy-saving design standards

Search Result 47, Processing Time 0.02 seconds

A Study on the Environment-Friendliness Evaluation of Sangsang Children's Park in Korea (국내 상상 어린이 공원의 친환경성 평가 연구)

  • Kim, Ja Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.169-180
    • /
    • 2014
  • Since Seoul city supplied 'Sangsang Children's Park', domestic children's parks are changing from formal facilities to creative play space recently. From eco-friendly safe playground model development project, the awareness of eco-friendly playground, namely children's park is increasing and its necessity is magnified. However, we could not know how well most children's parks aimed at the eco-friendly playground reflect eco-friendly features and whether they are eco-friendly or not because there are not the specific planning guidelines and evaluation standards for making the eco-friendly playground or children's park. Therefore, in this study we established the environment-friendliness evaluation standards of children's parks and estimated the environment-friendly features of the 9 parks built on the subject of green among Sangsang Children's Parks. In the observational survey of the 9 parks, we evaluated the environment-friendliness of these parks in the 8 fields(location and placement, ecological environment, play space, play equipment and facilities, additional facilities, materials and resources, energy saving, environmental load reduction) according to the levels(suitable, partial reflection, unsuitable, non-reflection) of reflection of eco-friendly planning factors. The assessment results showed that 4 items (location and placement, additional facilities, play space, play equipment and facilities) were suitable and others (energy saving, environmental load reduction, ecological environment, materials and resources) were partial reflection or unsuitable. Therefore, on the basis of these results, this study proposed the planning indicators to be considered first and the planning factors that should be complemented and improved in the construction of eco-friendly children's park in future.

A Suitability Analysis on the legal standards of the Rural Housing Standard Plans (농촌주택 표준설계도의 관련 법적 기준에의 적합성 분석 연구)

  • Jeon, Young-Hoon;Shin, Doo-Sik
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • The Rural Housing Standard Plans for improving the quality of life and housing stability in rural areas has been developed 87 types from 1994 to 2012. However, some types of Plans do not satisfy the current legal standard in accordance with social and legal changes. Standard plans has the same effect as a building permit, and replace it, so legal suitability of Plans is an important. Therefore, it is required the suitability analysis on the legal standards of Rural Housing Standard Plans. The Purpose of this study is to derive improper types and items of the Rural Housing Standard Plans on the legal standards. In this study, we analyzed its suitability on the legal standards(law on fire-fighting system installation and safety management, energy saving design criteria for buildings, structural checklist for small buildings, the types of drawing for building permit) in accordance with "rules for the operation of standard plans". And we analyzed the utilization of the Rural Housing Standard Plans through downloads from welchon portal.

Investigation on the current lighting level at the gas stations and its improvement methods (주유소 조명 실태와 개선 방안)

  • 주윤석;이동호;임종국;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.55-59
    • /
    • 1998
  • This paper investigates the illuminance level at the existing gas stations and compares the results with the KS and IESNA standards. The measured illuminance level in the pump island area is found to be high up to 3 times the recommended value in KS and somewhat lower than one in IESNA standard. From this results we conclude that significant degree of energy saving can be possible from proper maintenance program, and careful consideration must be paid in the design process. And the KS standard need to be examined more thoroughly against other nation's standards.

  • PDF

A Study on the Improvement of G-SEED through Analysis of Previous Studies on School Facilities (학교시설의 녹색건축인증제 개선을 위한 문헌분석에 관한 연구)

  • Yun, Yo-Sun;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.2
    • /
    • pp.41-51
    • /
    • 2014
  • Green Standard for Energy and Environmental Design(G-SEED) has been implemented for the realization of sustainable development and resource-saving and eco-friendly buildings from 2002. Studies about the green buildings are made actively and is being developed through constant revision. However, study results of green building have not been fully reflected in the standard. Therefore, this study analyzes the previous studies about G-SEED for school facilities and check the degree of to reflect the problems and improvements suggested in previous studies. This study will be a reference of future revision Substantial problems and requirements are not reflected in revision standard. Proposed improvement requirements are classed as to improve the items(establish specific standards, supplementation), strengthen standards(designate the prerequisite items), propose a new evaluation method, add new items. delete exist items and adjust the score. Therefore, future revision of G-SEED for school facilities should reflect the results of previous studies.

Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings (노후 고등학교 건물의 에너지효율화 리모델링을 위한 요소기술의 성능 평가)

  • Lhee, Sang Choon;Choi, Young Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.97-102
    • /
    • 2013
  • Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.

Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location (한국형 아파트의 난방에너지 분석 1: 위치의 영향)

  • 유호선;현석균;박유원;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.101-110
    • /
    • 2004
  • This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

Improvement Method of Regional Insulation Standard through the Regional Heating Energy Demand Analysis (권역별 난방에너지 요구량 분석을 통한 단열기준 개선방안)

  • Kim, Jeong-Gook;Ahn, Byung-Lip;Jang, Cheol-Yong;Jeong, Hak-Geun;Haan, Chan-Hoon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2013
  • The effect of climate change has influenced humanity and ecosystem with tremendous changes in temperature. For the past 150 years, the national annual average temperature is 0.6 degree increased and the heating degree day reduced from April to November. However, December to January, the climate change was generated and the heating degree day increased. The blackout occured in 2011 and 2012 by increasing electricity consumption of heating and cooling equipment to the effects of climate change. That is because heating load accounted for 20% of building electric use. In this study, strengthening measures to reduce heating energy consumption is presented due to climate change in winter since 1980 to prevent blackout and reliable power supply for the building energy-saving design standards by Meteorological data provided by the National Weather Service were calculated using the heating degree days in order to present eighteen cities from 1980 to 2012. Insulation standards are presented to prevent black-out by the heating degree days. the heating energy demand was reduced almost 6% including 10% in Central, 5% in South and Jeju area based on strengthening of the insulation. It is applied to the entire country an annual economic effect of 250 billion won, and black-out can be prevented.

A Study on the Application State of the Fenestration Energy Consumption Efficiency Rating System in Construction Field (소규모 민간건축 시공현장에 있어서 창호에너지 소비효율등급제의 적용 현황에 관한 연구)

  • Kang, Suk-Pyo;Jin, Eun-Mi;Yun, Yeo-Myun;Park, Sang-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.24-25
    • /
    • 2014
  • Up to now, most the fenestration industry is consisted of glazing and window frame in Korea. According to the Fenestration Energy Consumption Efficiency Rating System and Energy Saving Design Standards of Buildings, u-value of fenestration is defined as the value of calculation with glazing and frame. For this reason, when applying for a building permit, in most cases, the official approval test report of the set of windows and doors is used. Nevertheless, in windows construction progresses, most construction manager take delivery of the glazing and frame separately. For those reason, windows and doors are constructed regardless of the report of the Fenestration Energy Consumption Efficiency Rating System in most construction fields. From now on, the research of the connection method between reality of policy and reality of construction fields should be carried out.

  • PDF

A Study on the Development of Building Control and management System -Focusing on the Lighting Control and Monitoring system- (빌딩 제어 및 관리 시스템 개발에 관한 연구 -조명 제어 관리 시스템 구축을 중심으로-)

  • Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.110-118
    • /
    • 2007
  • Technology has been viewed at various stages of civilization as leading to future progress. The building, its services systems and management of the work process all contribute to the well-being of people within an organization. Productivity relies on there being a general sense of high morale and satisfaction with the workplace. Now buildings are considered as providing a milieu for human creativity. Flexibility, adaptability, service integration and high standards of finishes offer an intelligence threshold. Building Automation System(BAS) - controlled lighting systems may offer incremental energy saving. Conventional Lighting control systems often control equipment in a single room or over the limited area, because they are centralized control systems, which means that all the controlled circuits must be wired to a single control panel. The computers used by these systems are typically dedicated microprocess that perform only lighting control functions. By comparison, modern Building automation systems are distributed control system, which means that their computing hardware and software are distributed as a network that microprocessor-based control modules and standard PC. PLC(Programmable Logic controller) is extensible virtually without limits, so that all the lighting in a facility can be controlled by single, unified system - the same system that also can control and monitor the building's HVAC, security, and manufacturing processed, elevators, and more. A Building automation system can control light using schedules, manual controls, occupancy sensors, and photosensors, either singly or in combination. Building Lighting control and monitoring system will be for a energy saving and efficient building management system.

A Study on the Eco-friendly Properties of Apartment Housing Playground in Germany (독일 공동주택 놀이터의 친환경적 특성 연구)

  • Kim, Ja Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.87-98
    • /
    • 2015
  • As an apartment house as well as improving quality of life is becoming one of the brands, it is increasing the importance of the outer space with the facilities in the housing complex. In particular, the outdoor playground such as the community facilities that children and adults share as the activity areas for residents has received attention. However, actually children have not used many of Korean apartment housing playgrounds that were installed formally in the scrap area according to the housing plan by residential construction standards. it is considered necessary to improve the quality of the playground in housing complex and reform it in order to make the eco-friendly play space in which children can play safely and h healthily. As an alternative, we analyzed the eco-friendly properties of the playgrounds installed in the eco-friendly housing complex in Germany and derived the main planning elements of eco-friendly playground. In the observational survey of the 10 playgrounds in 9 housing complexes in 5 regions in Germany, we evaluated the environment-friendliness of these playgrounds in the 8 fields(location and placement, ecological environment, play space, play equipment and facilities, additional facilities, materials and resources, energy saving, environmental load reduction) according to the levels(suitable, partial reflection, unsuitable, non-reflection) of reflection of eco-friendly planning factors. The following is the summary of the results about the reflection of eco-friendly planning factors. In terms of "suitable": location and placement(88.8%), play equipment and facilities(73.5%), additional facilities(60.6%), environmental load reduction(54%), and ecological environment(50%) were higher than others. In terms of "unsuitable": there was nothing. In terms of "non-reflection": energy saving(95%), additional facilities(32.2%), and materials and resources(30.9%) were in order. Therefore, on the basis of these results, this study proposed the planning indicators to be considered first and the planning factors that should be complemented and improved in the construction of apartment housing playground in future.