• Title/Summary/Keyword: Energy utilization plan

Search Result 76, Processing Time 0.027 seconds

A Study for Integrated Ocean Energy Utilization System (해양에너지의 복합이용시스템에 관한 기초연구)

  • 김현주;홍석원
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.83-86
    • /
    • 2001
  • This paper aims to make a feasibility study and to propose a master plan for the development of "integrated ocean energy utilization system", which utilizes various renewable ocean energies. Fossils energy, as the most important energy resources which are inevitable for the living and industrial development, becomes exhausted and its consumption creates serious environmental problem. It is important to utilize renewable ocean energy for a sustainable and environmentally friendly development. We survey the integrated utilization of ocean energy based on surveyed energy density distribution and propose concepts of integrated ocean energy utilization plant for both onshore and offshore system. The results of this study can support national effort for renewable energy development utilizing integrated ocean energy and refer as a guideline for the technical development of sustainable integrated ocean energy.

  • PDF

A Study on the Reset of Examination Criteria for Energy Use Plan through Consultation Case Analysis (협의 사례 분석을 통한 에너지사용계획 검토기준 재설정 연구)

  • Suh, Kwang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.59-69
    • /
    • 2013
  • The Consultation about Energy Use Plan is prescribed by the Energy Use Rationalization Act. In order to reset Examination Criteria for Energy Use Plan, consultation case analysis from 2001 to 2010 were carried out and National Energy Master Plan was reviewed. This study proposes that Examination Criteria for Energy Use Plan be should divided into Urban & Tourism complex development project and Industrial complex development project for the prevention of civil complain. Also predicts that effect of energy savings calculated by Reset Examination Criteria on $1^{ST}$ energy demand BAU at 2030 is 2.2%, effect of new & renewable energy utilization at 2030 is 3% and the rate of $CO_2$ reduction to greenhouse gas emission BAU at 2020 is 1.1%.

A Study on Fostering Plan for the Hydrogen Industry in Changwon City (창원시 수소 산업 2040 중장기 육성계획 수립 연구)

  • PARK, MIN-JU;KIM, HAK-MIN;GU, YUN-JEONG;JEONG, CHANG-HOON;KANG, BOO MIN;HA, SEUNG WOO;JEONG, DAE-WOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.509-521
    • /
    • 2020
  • This study aims to propose a mid- to long-term fostering plan for the hydrogen industry customized to Changwon City by reviewing the government's policy and the status of the domestic and foreign hydrogen industry. The adopted methodologies were policy analysis, literature review, field investigation, and committee operation that could consider institutions, knowledge (technology), and networking between activity subjects. The short-term projects and long-term projects for the fostering plan are established using these methodologies. The short-term projects were structured so that the ongoing hydrogen industry fostering plan leads to a successful result, and the hydrogen mobility field is expanded to not only land vehicles but also marine and air vehicles. The long-term projects consist of a high proportion of the hydrogen utilization field to take advantage of the industrial strength of Changwon City, and a support system for new and turning companies for localization of parts was added to provide industrial competitiveness.

A Study of Improving Regenerative Energy Utilization in Urban DC Railway Systems Through Sharing Substations (철도 변전소 공유를 통한 직류 도시철도 시스템 회생에너지 이용률 향상 방안 연구)

  • Jung, Seung-Min;Lee, Han-Sang;Byun, Gil-Sung;Kwon, Sae-Hyuk;Jang, Gil-Soo;Jung, Ho-Sung;Kim, Hyung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2392-2396
    • /
    • 2011
  • This paper deals with the power integration of large urban railway systems to improve regenerative energy utilization. Current regenerative energy utilization is low because there is no special plan for using this energy. If the railway system is integrated with other railway systems, the efficiency is expected to be improved. Through the case studies, to find the realistic effect of integrated operation, real system for the Seoul Metro lines, especially line 5 and 7, had been applied.

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

A Study on Reset of Examination Criteria for Energy Use Plan by Projet Sector (사업 분야별 에너지사용계획 검토기준 재설정에 관한 연구)

  • Suh, Kwang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6581-6589
    • /
    • 2013
  • This study reset the Examination Criteria for Energy Use Plan by the project sector so that the Consultation about Energy Use Plan would play an effective role in reaching the National Energy Policy Issues, and to prevent complaints from the superintendent of the project & agent engaged in the project. To achieve this aim, consultation case analysis was carried out from 2001 to 2010 and the National Energy Master Plan was reviewed. The predicted effect of energy savings calculated by reset Examination Criteria on the $1^{st}$ energy demand target at 2030 was 2.5%, the effect of new and renewable energy utilization on a new and renewable energy supply target at 2030 was 3% and the rate of $CO_2$ reduction to greenhouse gas emission BAU at 2020 was 1.1%.

A Study on Peak Power Reduction using Regenerative Energy in Railway Systems through DC Subsystem Interconnection

  • Jung, Seungmin;Lee, Hansang;Kim, Kisuk;Jung, Hosung;Kim, Hyungchul;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1070-1077
    • /
    • 2013
  • Owing to the consistent increase in energy efficiency issues, studies for improving regenerative energy utilization have been receiving attention in the Urban DC railway systems, where currently, the utilization of regenerative energy is low due to the lack of a specific plan for using this energy. The regenerative energy in railway systems has a low efficiency problem which results in the increase of the catenary voltage and a possibility to create problems to the electrical devices connected to the system. This paper deals with the power integration of large urban railway subsystems to improve regenerative energy utilization where the railway subsystems are integrated with other railway subsystems to improve the energy efficiency. Through the case studies, to find the realistic effect of integrated operation, the Seoul Metro subsystems, namely Line 5 and Line 7, has been applied. Also, evaluation for the electricity cost saving has been performed by using KEPCO electricity cost table.

A Study on the Application Plan of Air-Conditioning and Renewable Complex Systems in the Small Schools. (소규모 학교의 냉난방 및 신재생에너지복합시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Hong, Sung-Hee;Kim, Seong-Sil;Hur, Inn-Ku;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.946-951
    • /
    • 2009
  • The research aims to study a new, optimum and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and water heating energy saving efficiencies for educational facilities. Therefore, this research carried out a study on the new/renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 174kW + solar heat collector $94\;m^2$ + highly efficient electronic cooling/heating device (EHP) 249.4kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 255.2kW + highly efficient electronic cooling/heating device (EHP) 168.2kW.

  • PDF

Examination of excess electricity generation patterns in South Korea under the renewable initiative for 2030

  • Kim, Philseo;Cho, So-Bin;Yim, Man-Sung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2883-2897
    • /
    • 2022
  • According to the Renewable Energy 3020 Implementation Plan announced in 2017 by the South Korean government, the electricity share of renewable energy will be expanded to 20% of the total electricity generation by 2030. Given the intermittency of electricity generation from renewable energy, realization of such a plan presents challenges to managing South Korea's isolated national electric grid and implies potentially large excess electricity generation in certain situations. The purpose of this study is: 1) to develop a model to accurately simulate the effects of excess electricity generation from renewables which would arise during the transition, and 2) to propose strategies to manage excess electricity generation through effective utilization of domestic electricity generating capabilities. Our results show that in periods of greater PV and wind power, namely the spring and fall seasons, the frequency of excess electricity generation increases, while electricity demand decreases. This being the case, flexible operation of coal and nuclear power plants along with LNG and pumped-storage hydroelectricity can be used to counterbalance the excess electricity generation from renewables. In addition, nuclear energy plays an important role in reducing CO2 emissions and electricity costs unlike the fossil fuel-based generation sources outlined in the 8th Basic Plan.

A Study on the Application Plan of Air-Conditioning and New and Renewable Systems in the Large High Schools (대규모 고등학교의 냉난방 및 신재생에너지시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Kim, Seong-Sil;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.564-574
    • /
    • 2009
  • The study is conducted to study a new, optimum and new and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and hot water supply energy saving efficiencies for educational facilities. Therefore, this research implemented a study on the new and renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 475.6 kW+highly efficient electronic cooling/heating device(EHP) 545.2 kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 261kW+solar heat collector $240\;m^2$+highly efficient electronic cooling/heating device(EHP) 759.8 kW.