• Title/Summary/Keyword: Energy textile

Search Result 324, Processing Time 0.031 seconds

A study on thermal behavior of energy textile by performing in-situ thermal response test and numerical simulation (현장 열응답 시험과 수치해석을 통한 터널에 적용된 에너지 텍스타일의 열적 거동 연구)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Jeoung, Jae-Hyeung;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.325-335
    • /
    • 2010
  • A new geothermal energy source obtained from a tunnel structure has been studied in this paper. The geothermal energy is extracted through a textile-type ground heat exchanger named "Energy Textile" that is installed between a shotcrete layer and a guided drainage geotexitle. A test bed was constructed in an abandoned railway tunnel to verify the geothermal heat exchanger system performed by the energy textile. To evaluate the applicability of the energy textile, we measured the thermal conductivity of shotcrete and lining samples which were prepared in accordance with a common mixture design. An overall performance of the energy textile installed in the test bed was evaluated by carrying out a series of in-situ thermal response test. In addition, a 3-D finite volume analysis (FLUENT) was adopted to simulate the operation of the ground heat exchanger being encased in the energy textile with the consideration of the effect of the shotcrete and lining thermal conductivity.

  • PDF

Study on long-term monitoring of heat exchanger installed in the tunnel lining (터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구)

  • Lee, Chulho;Park, Moonseo;Choi, Hangseok;Sohn, Byunghu;Jeoung, Jaehyeung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

Low Carbonization Technology & Traceability for Sustainable Textile Materials (지속가능 섬유 소재 추적성과 저탄소화 공정)

  • Min-ki Choi;Won-jun Kim;Myoung-hee Shim
    • Fashion & Textile Research Journal
    • /
    • v.25 no.6
    • /
    • pp.673-689
    • /
    • 2023
  • To realize the traceability of sustainable textile products, this study presents a low-carbon process through energy savings in the textile material manufacturing process. Traceability is becoming an important element of Life Cycle Assessment (LCA), which confirms the eco-friendliness of textile products as well as supply chain information. Textile products with complex manufacturing processes require traceability of each step of the process to calculate carbon emissions and power usage. Additionally, an understanding of the characteristics of the product planning-manufacturing-distribution process and an overall understanding of carbon emissions sources are required. Energy use in the textile material manufacturing stage produces the largest amount of carbon dioxide, and the amount of carbon emitted from processes such as dyeing, weaving and knitting can be calculated. Energy saving methods include efficiency improvement and energy recycling, and carbon dioxide emissions can be reduced through waste heat recovery, sensor-based smart systems, and replacement of old facilities. In the dyeing process, which uses a considerable amount of heat energy, LNG, steam can be saved by using "heat exchangers," "condensate management traps," and "tenter exhaust fan controllers." In weaving and knitting processes, which use a considerable amount of electrical energy, about 10- 20% of energy can be saved by using old compressors and motors.

Study on Thermal Performance of Energy Textile in Tunnel (터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구)

  • Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1907-1914
    • /
    • 2013
  • Textile-type heat exchangers installed on the tunnel walls for facilitating ground source heat pump systems, so called "energy textile", was installed in an abandoned railroad tunnel around Seocheon, South Korea. To evaluate thermal performance of the energy textile, a series of long-term monitoring was performed by artificially applying daily intermittent cooling and heating loads on the energy textile. In the course of the experimental measurement, the inlet and outlet fluid temperatures of the energy textile, pumping rate, temperature distribution in the ground, and air temperature inside the tunnel were continuously measured. From the long-term monitoring, the heat exchange rate was recorded as in the range of 57.6~143.5 W per one unit of the energy textile during heating operation and 362.3~558.4 W per one unit during cooling operation. In addition, the heat exchange rate of energy textile was highly sensitive to a change in air temperature inside the tunnel. The field measurements were verified by a 3D computational fluid dynamics analysis (FLUENT) with the consideration of air temperature variation inside the tunnel. The verified numerical model was used to evaluate parametrically the effect of drainage layer in the energy textile.

Change of Main Body Temperature and Reduction of Energy Consumption in a 1 Tube 2 Chamber Bent Silkworm Type Dyeing Machine

  • Lee, Choon-Gil;Woo, Kyung-Sung
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.550-556
    • /
    • 2002
  • The changes of the main body temperature of a I tube 2 chamber bent silkworm type dyeing machine and the reduction of energy consumption of the dyeing machine by the energy saving design are reported. This dyeing machine was developed for the purpose of the energy saving and high efficiency. In this study, the changes of the main body temperature of the 1 tube 2 chamber bent silkworm type dyeing machine were studied experimentally. Especially the effect of the blower motor electric current and the main body pressure at various blower frequencies were studied experimentally. In the experimental data for the changes of main body temperature, it was shown that the main body temperature increased as the blower motor electric current and the main body pressure increased.

Further Electrochemical Degradation of Real Textile Effluent Using PbO2 Electrode

  • Wang, Chao;Tian, Penghao
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.266-271
    • /
    • 2021
  • A commercial PbO2 electrode was adopted as the anode for the electrochemical degradation of the real textile effluent with the initial COD of 56.0 mg L-1 and the stainless steel plate as the cathode. The effect of the initial pH, the electrolyte flow rate and the cell voltage on the COD, the current efficiency and the energy consumption were investigated without the addition of NaCl or Na2SO4. The experimental results illustrated that the PbO2 electrode can reduce the COD of the textile effluent from 56.0 mg L-1 to 26.0 mg L-1 with the current efficiency of 86.1% and the energy consumption of 17.5 kWh kg-1 (per kilogram of degraded COD) under the optimal operating conditions. Therefore PbO2 electrode as the anode was promising to further electrochemically degrade the real textile effluent.

Abrasion of PET Fabrics by Using Microwave Energy (Microwave Energy를 이용한 PET 직물의 Abrasion)

  • Cho, In-Sul;Lee, Eun-Woo;Cho, Kyu-Min;Chang, Du-Sang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.69-72
    • /
    • 1999
  • The aim of this study is to enhance the abrasion of the hydrolyzed polyethylene terephthalate(PET) fabrics by using microwave energy. In other to achieve the aforementioned objectives, PET fabrics were hydrolyzed in NaOH solution by using abrasion method such as dipping, microwave-dipping, pad steam-dry, and pad microwave-dry, and then abrasion of the hydrolyzed PET fabrics was calculated and investigated. As a result obtained form this study, the abrasion of the hydrolyzed PET fabrics is directly proportional to hydrolyzed time and NaOH concentration. And also, microwave-dipping method and pad microwave-dry method showed remarkable abrasion effect than the others.

  • PDF

On the Change of Fabric Mechanical properties in Ultrasonic Fabric Washing System (호부직물의 초음파 수세에 의한 역학적 특성의 변화)

  • Lee, Choon-Gil;Park, Sung-Diuk;Oh, Bong-Hyo
    • Textile Coloration and Finishing
    • /
    • v.9 no.4
    • /
    • pp.28-38
    • /
    • 1997
  • Peach skin fabrics were washed by the general and ultrasonic washing systems using different conditions. The physical properties of the washed fabrics were estimated. The following results were obtained through experimental data and their analysis. The tensile properties were changed due to fabric running speed and washing methods. The lower the running speed, the higher the extensibility and resilience and the lower the linearity and tensile energy. In the general washing method, the extensibility and resilience had lower values than those of the ultrasonic washing method and the linearity and tensile energy had the higher values than those of the ultrasonic washing system. The bending properties, bending moment and histeresis, were estimated. These values were generally lower in the ultrasonic washing system than those of the general washing system. The faster the washing speed, the higher the value of hysterisis. The shear properties were affected by the fabric running speed and washing methods. Shear stiffness and hysteresis of shear forces increased according to the increase of the fabric running speed. The values were higher in the general washing system than those of the ultrasonic washing system. The compressional energy was affected by the fabric running speed. The higher the fabric speed the higher the compressional energy. The ultrasonic washing system had lower compressional energy than the general washing system. The higher the running speed, the lower the coefficient of friction and geometrical roughness. The values of geometrical roughness were infienced by the removal of the sizing agent. The higher the remaining sizing agent, the higher the fabric weight and the thicker the thickness of fabric.

  • PDF

The Effect on Menstrual Pain of the Space Energy Application Underwear (공간에너지 적용 속옷이 생리통 완화에 미치는 영향)

  • Lee, Sung-Ok;Jang, Jeong-Dae
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.743-751
    • /
    • 2011
  • For the reduction of menstrual pain, treatment and taking medicine will be able to reduce the temporary ache but the grievous pain will be able to occur with the side effect in medicine, if menstrual pain without side effect for health of the woman which is comfortable mind is possible, it will be able to minimize. Consequently for this study that wearing the underwear which irradiates a space energy reduce menstrual pain, the fundamental data which relaxes the various complex condition will be able to provide and effectiveness of space energy will be able to reduce menstrual pain. Research result, when the underwear which irradiates a space energy wore, the menstrual pain was decreased, the underwear satisfaction increased.