• Title/Summary/Keyword: Energy system analysis

Search Result 6,740, Processing Time 0.037 seconds

The Feasibility Analysis of Organic Waste Bioenergy System in Apartment Complex (유기성 폐자원 바이오에너지 시스템의 공동주택 적용 타당성 평가에 관한 연구)

  • Ko, Myeong-Jin;Choi, Mi-Young;Choi, Doo-Sung;Kim, Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.474-481
    • /
    • 2010
  • Because international environmental and energy problems such as global warming and ozone depletion, exhausting of fossil energy sources are more serious than before, renewable energy system is attracting people's attention more and more. Organic waste bioenergy system among a variety of renewable energy system is expected to have an effect on building a society which is eco-friendly and recycles resources owing to carbon neutral effects. So this is considered as the role of an energy source of the building. Previous studies on the organic waste bioenergy are mainly bioenergy technology and activation plan of the bioenergy supply. But the performance evaluation studies of bioenergy systems installed in buildings are rarely. This study is to evaluate applicability of the organic waste bioenergy system as the building energy supply system by energy and environmental, economical analysis.

Analysis of Economics through Control Method of Heat Source Equipment in Seasonal Air conditioning Building

  • Park, Yool;Kim, Samuel;Jung, Soon-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2003
  • The term “energy saving is economical” is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing a system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning systems. For this reason, this research can provide the economic operating number control method as basic design data. The data obtained through analysis of life cycle cost based on amount of yearly energy use, are produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating$.$cooling systems based on seasonal air conditioning system, which is widely used for medium and large size office buildings in Busan.

A Study on Complexity Analysis of Extensible Profile Verification Software for Energy Storage System (에너지저장장치용 확장성 프로파일 검증 소프트웨어 복잡도 분석에 관한 연구)

  • Kwon, Hyeokyoung;Ryu, Youngsu;Park, Jaehong;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.17 no.5
    • /
    • pp.59-65
    • /
    • 2016
  • Recently, a study has been progressed about the energy storage system for resolving energy shortage problems in the world. The energy storage system can maximize energy storage system's energy usage by monitoring and controlling about all energy infrastructures on energy network. However, compatibility problems among main components or devices of the energy storage system are obstacles to development of energy storage system products. An extensible profile and extensible profile verification software being able to verify the extensible profile have been required in order to resolve compatibility problems. In this paper, the study on complexity analysis for the extensible profile verification software for the energy storage system is performed. A XML based profile and C language structure based profile are used for analysis of the profile verification software. The complexity of complex verification structure that parses the XML based profile several times and simple verification structure that parses the C language structure based profile are analyzed and compared. Time complexity, space complexity, and cyclomatic complexity are used for complexity analysis. By using these complexity analysis, the study result that compares and analyzes the complexity of XML based and C language structure based profile verification software is presented.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

Shaking table test and numerical analysis of a combined energy dissipation system with metallic yield dampers and oil dampers

  • Zhou, Qiang;Lu, Xilin
    • Structural Engineering and Mechanics
    • /
    • v.17 no.2
    • /
    • pp.187-201
    • /
    • 2004
  • A shaking table test on a three-story one-bay steel frame model with metallic yield dampers and their parallel connection with oil dampers is carried out to study the dynamic characteristics and seismic performance of the energy dissipation system. It is found from the test that the combined energy dissipation system has favorable reducing vibration effects on structural displacement, and the structural peak acceleration can not evidently be reduced under small intensity seismic excitations, but in most cases the vibration reduction effect is very good under large intensity seismic excitations. Test results also show that stiffness of the energy dissipation devices should match their damping. Dynamic analysis method and mechanics models of these two dampers are proposed. In the analysis method, the force-displacement relationship of the metallic yield damper is represented by an elastic perfectly plastic model, and the behavior of the oil damper is simulated by a velocity and displacement relative model in which the contributions of the oil damper to the damping force and stiffness of the system are considered. Validity of the analytical model and the method is verified through comparison between the results of the shaking table test and numerical analysis.

Investigation of Vibration Characteristics using Experimental Statistical Energy Analysis(ESEA) (시험적인 통계적 에너지 기법(ESEA)을 적용한 진동 전달 특성 연구)

  • 이화수;우관제;김종년;이태욱
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.113-118
    • /
    • 2002
  • Vibrational characteristics of coupled beam & plate system are considered on simple system, which consists of plates(2-subsystem) and beams(4-subsystem), using experimental statistical energy analysis(ESEA). First, damping and coupling loss factors of the system are determined by power injection method (PIM). Then, energy distribution of all the subsystem is estimated from the power balance equation. Finally, these quantities are compared with measured energy. The correlation of measured and estimated results for the sample problem is reasonably good.

  • PDF

Voltage and Transient State Analysis of Distribution Line connected to Wind Power Generation (풍력발전이 연계된 배전선로 전압 및 과도상태 해석)

  • Kim, Se-Ho;Na, Kyoung-Yoon;Kim, Gun-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.61-67
    • /
    • 2006
  • The use of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and therefore, it is important to respect and to deal with the impact of wind power generation system. From the view of an electric grid utility, there is a major problem with the impact of the wind system on the voltage of the electric grid, to which a turbine is connected. In this paper, it is investigated the voltage impact and transient state analysis on distribution line, with which wind power generation system is connected. Connections of wind power system usually occur to voltage drop due to reactive power absorption and sometime result in higher than nominal voltage.

Forced Convection heated and cooled SMA(Shape Memory Alloy) Actuator (강제대류 열전달을 이용한 형상기억합금 작동기)

  • Jun Hyoung Yoll;Kim Jung-Hoon;Park Eung Sik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.100-103
    • /
    • 2005
  • This work discusses the numerical analysis, the design and experimental test of the SMA (Shape Memory Alloy) actuator along with its capabilities and limitations. Convection heating and cooling using water actuate the SMA element of the actuator. The fuel such as propane, having a high energy density, is used as the energy source for the SMA actuator in order to increase power and energy density of the system, and thus in order to obviate the need for electrical power supplies such as batteries. The system is composed of a pump, valves, bellows, a heater (burner), control unit and a displacement amplification device. The actuation frequency is compared with the prediction obtained from numerical analysis. For the designed SMA actuator system, the results of numerical analysis were utilized in determining design parameters and operating conditions.

  • PDF

Integrity of the Reactor Vessel Support System for a Postulated Reactor Vessel Closure Head Drop Event

  • Kim, Tae-Wan;Lee, Ki-Young;Lee, Dae-Hee;Kim, Kang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.576-582
    • /
    • 1996
  • The integrity of reactor vessel support system of the Korean Standard Nuclear Power Plant (KSNPP) is investigated for a postulated reactor vessel closure head drop event. The closure head is disassembled from the reactor vessel during refueling process or general inspection of reactor vessel and internal structures, and carried to proposed location by the head lift rig. A postulated closure head drop event could be anticipated during closure head handling process. The drop event may cause an impact load on the reactor vessel and supporting system. The integrity of the supporting system is directly relevant to that of reactor vessel and reactor internals including fuels. Results derived by elastic impact analysis, linear and non-linear buckling analysis and elasto-plastic stress analysis of the supporting system implied that the integrity of the reactor vessel supporting system is intact for a postulated reactor vessel closure head drop event.

  • PDF

Definition and calculation method of modal effective mass of asymmetric fluid-structure interaction system for seismic analysis

  • Yong-Hwa Heo;Jong-Oh Sun;Gyeong Ho Kim;Yeonseok Choo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4307-4316
    • /
    • 2023
  • In this paper, modal effective mass for asymmetric fluid-structure interaction system is defined and equations for its calculation is derived. To establish consistency, modal effective mass in symmetric structure only system is briefly reviewed, followed by a definition of the modal effective mass in asymmetric system. The equations for calculating modal effective mass in asymmetric system are derived by utilizing the properties of left and right eigenvectors. To simplify the equations, the assumption is made that the mass matrix is only affected by the fluid. The simplified equation is then compared to the equation already used in ANSYS. Finally, the validity of the modal effective mass definition and derivation in this paper is demonstrated through a simple example.