• 제목/요약/키워드: Energy performance analysis

검색결과 4,219건 처리시간 0.031초

회귀 모델을 활용한 철강 기업의 에너지 소비 예측 (Forecasting Energy Consumption of Steel Industry Using Regression Model)

  • Sung-Ho KANG;Hyun-Ki KIM
    • Journal of Korea Artificial Intelligence Association
    • /
    • 제1권2호
    • /
    • pp.21-25
    • /
    • 2023
  • The purpose of this study was to compare the performance using multiple regression models to predict the energy consumption of steel industry. Specific independent variables were selected in consideration of correlation among various attributes such as CO2 concentration, NSM, Week Status, Day of week, and Load Type, and preprocessing was performed to solve the multicollinearity problem. In data preprocessing, we evaluated linear and nonlinear relationships between each attribute through correlation analysis. In particular, we decided to select variables with high correlation and include appropriate variables in the final model to prevent multicollinearity problems. Among the many regression models learned, Boosted Decision Tree Regression showed the best predictive performance. Ensemble learning in this model was able to effectively learn complex patterns while preventing overfitting by combining multiple decision trees. Consequently, these predictive models are expected to provide important information for improving energy efficiency and management decision-making at steel industry. In the future, we plan to improve the performance of the model by collecting more data and extending variables, and the application of the model considering interactions with external factors will also be considered.

5ESS-2000 통신장비실의 열환경특성과에너지성능 개선방안에 관한 연구 (A Study on the Characteristics of Thermal Environment and Improvement of Energy Performance in 5ESS-2000 Telecommunication Equipment Room)

  • 이승복;조춘식
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.19-26
    • /
    • 2004
  • The purpose of this study was to evaluate the thermal environment of present state and energy consumption and to verify the improvement of energy performance applying free cooling in 5ESS-2000 telecommunication equipment room. Analysis program is used the DOE-2.1E and commercial CFD code, Star-CD. The results of the simulation show that free cooling could reduce 42.1% of cooling energy, increase 48.5% of heating energy because introduced outdoor air must heating and humidification. Therefore free cooling could reduce yearly 34,609.9 kWh of heating and cooling energy and this is reaching to 21.6% of total energy.

Prediction of TBM performance based on specific energy

  • Kim, Kyoung-Yul;Jo, Seon-Ah;Ryu, Hee-Hwan;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • 제22권6호
    • /
    • pp.489-496
    • /
    • 2020
  • This study proposes a new empirical model to effectively predict the excavation performance of a shield tunnel boring machine (TBM). The TBM performance is affected by the geological and geotechnical characteristics as well as the machine parameters of TBM. Field penetration index (FPI) is correlated with rock mass parameters to analyze the effective geotechnical parameters influencing the TBM performance. The result shows that RMR has a more dominant impact on the TBM performance than UCS and RQD. RMR also shows a significant relationship with the specific energy, which is defined as the energy required for excavating the unit volume of rock. Therefore, the specific energy can be used as an indicator of the mechanical efficiency of TBM. Based on these relationships with RMR, this study suggests an empirical performance prediction model to predict FPI, which can be derived from the correlation between the specific energy and RMR.

주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가 (Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building)

  • 김용식;김중헌;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구 (Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses)

  • 이충국;이정철;김상수;서승직
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

일체형 순수유압식 브레이커의 민감도해석에 의한 성능 향상 (Performance Improvement of an Integrated-type Fully-Hydraulic Breaker by Sensitivity Analysis)

  • 최석;장효환
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.17-24
    • /
    • 2009
  • The performance improvement of a small-size integrated-type fully hydraulic breaker is studied in this paper. Mathematical modeling of the breaker is established and verified by experiment. Through sensitivity analysis using AMESim, the key design parameters are selected and nearly optimized to maximize the impact energy as well as to improve the dynamic characteristics such as the piston upper chamber pressure, piston and valve displacements. As a result, the impact energy, blows per minute(bpm) and output power are increased by 52.9%, 1%, and 55.6%, respectively compared with the current design. The dynamic characteristics of the piston upper chamber pressure, piston and valve displacements are also improved by the design change.

  • PDF

Zero Energy School(ZES) 에너지절감 성과 검증을 위한 방법론 연구 (A methodology for verification of energy saving performance of Zero Energy School (ZES))

  • 이항주;안종욱;김인수
    • 에너지공학
    • /
    • 제28권1호
    • /
    • pp.37-44
    • /
    • 2019
  • 국내 건축물은 국가 온실가스 배출의 25%, 에너지소비의 20%를 차지하고 있어 건축물의 에너지 효율향상이 국가 에너지수요관리의 주 대상으로 인식되고 있다. 건축물의 에너지효율향상을 위해 "제로에너지건축물 국가 로드맵"을 작성하여 정책들을 시행하고 있으며, 제로에너지건축물 의무화 확대의 따라 조기 활성화를 통한 국가 건물에너지 수요관리 효율성을 제고 하고 있다. 또한 건축물이 완공되고 그 후 에너지절감량에 대한 성과검증에 대한 필요성 또한 높아지고 있다. 이에 따라 건축물의 에너지 성능을 평가하기 위한 방법들이 제시되어야 할 것이다. 본 논문은 국제표준 및 가이던스 분석과 동시에 국내 학교를 현장 방문하여 각종 변수 등에 대한 조사 분석을 통하여 국제적으로 적용 가능한 제로에너지스쿨의 에너지성과검증 방법을 개발, 제시하고자 한다.

분류층 가스화기 특징 및 공정모사 분석 (Characteristics and Modeling Analysis of Entrained Flow Gasifiers)

  • 유정석;김유석;백민수
    • 신재생에너지
    • /
    • 제9권3호
    • /
    • pp.20-28
    • /
    • 2013
  • The gasification process has developed to convert coal into the more useful energy and material since decades. Despite the numberous design of ones, entrained flow gasifier of the major companies has had an advantage on the market. Because it has a merit of full-scale and high performance plant. In this paper, the gasification technologies of GE energy, Phillips, Siemens and Shell have been reviewed to compare their characteristics and a high performance gasification process was suggested. And the simulation model of gasifiers using Aspen Plus offered the quantitative comparison data for difference designs. The simulation results revealed the poor performance of the slurry feed than dry design. The corresponding cold gas efficiency of 77% is much lower than the 80.3% for the dry feed cases. The exergy analysis of the difference syngas quenching system showed that chemical quenching is superior to another. The results of analysis recommend the two stage gasifier with dry multi-feeder as the energy effective design.

에너지 생산성 분석 기반 양면발전형 수직 태양전지의 활용 가능성 탐색 (A Study on the Applicability of Double-Sided Vertical Photovoltaic Panels Based on Energy Productivity Analysis)

  • 최승주;한승훈
    • 신재생에너지
    • /
    • 제19권4호
    • /
    • pp.84-97
    • /
    • 2023
  • This study aimed to investigate the feasibility and potential applications of utilizing bifacial photovoltaic (PV) panels from an architectural perspective. It also aimed to establish a foundational dataset for installation and operational guidelines for bifacial PV panels through a comparative analysis of energy production performance with single PV panels. The research encompassed several key steps, including a comprehensive literature review, calculation of solar surface radiation values, development of datasets for bifacial and single PV energy production, and a performance comparison between both approaches. The results of the study show that bifacial PV panels exhibit optimized energy production capabilities within the range of 40 to 80 degrees, contingent upon the specific installation location. Consequently, it is recommended that the installation of bifacial PV panels in Korea should primarily focus on southwest-to-west orientation. Furthermore, it was concluded that bifacial PV panels could contribute an equivalent or even superior level of energy production compared to single PV panels, even if their performance exhibited a marginally lower efficiency of 2% to 5% with an 18% power generation efficiency.

무선 센서네트워크 환경에서 Duty Cycle 기반 동기식 및 비동기식 MAC 프로토콜의 에너지 성능과 지연시간에 대한 상호 분석 (The Energy Performance Analysis Between Synchronous and Asynchronous Duty Cycle based MAC Protocols in Wireless Sensor Networks)

  • 이재호;엄두섭
    • 한국IT서비스학회지
    • /
    • 제10권3호
    • /
    • pp.237-250
    • /
    • 2011
  • Recently, Wireless Sensor Networks (WSN) require energy performance and guaranteed delivery delay time, contrarily with previous MAC protocols that aim to high throughput mostly. In order to satisfy the new significant requirements, many MAC protocols of WSN employ and try to enhance the duty cycle mechanism which is energy efficient technique in MAC layer. This duty cycle mechanism is oriented by toggling the transceiver conditions composed of wakeup and sleep states. The synchronous MAC protocols perform the period synchronization process. Hence, these are energy efficient in periodic monitoring environment, but are inefficient in where an event is incurred rarely and infrequently. Otherwise, the performance of asynchronous MAC protocols are contrarily with synchronous protocols. In this paper, we design two models consisting Always-busy and Always-idle ti simplify the general network congestion conditions. Through these models, moreover, we analyze two types MAC protocols in terms of energy efficiency and delay performance by analytical results. Additionally, we also evaluate two MAC protocols with two gongestion models that we designed. By the analytical and simulated results, we provide the general and efficient decision method in which protocols are more appropriate in a certain WSN environment.