• Title/Summary/Keyword: Energy of combustibles

Search Result 17, Processing Time 0.022 seconds

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron (전기다리미의 발화원인 판정에 관한 현상학적 고찰)

  • Mun, Yong-Soo;Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

Comparative Study on the Estimation Method of Fire Load for Residential Combustibles (주거공간 가연물의 화재하중 산정방법의 비교연구)

  • Choi, Su-Young;Kim, Jung-Yong;Nam, Dong-Gun;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.38-43
    • /
    • 2013
  • As a preliminary study to evaluate the reliability of the calculation method of fire load for residential furniture combustibles, the present study estimates the fire load considering the volume data obtained by the 3D geometrical information of combustibles and material properties based on the literature survey and sample burning test. A kitchen sink cabinet, couch and workstation were investigated for estimating its fire load and real fire test have been performed to measure total energy released from the combustibles. Based on total energy measured from real fire test, the relative error of the estimated fire load due to literature survey and measured material properties showed 6~120% and less than 20%, respectively. It shows that the estimation error of fire load are greatly affected by its material properties as well as geometrical information of combustibles and the present study will be able to contribute to accurate estimation of fire load.

Reclaimed Products to Recycling and Energy Recovery for Sustainable Use of Closed Non Sanitary Landfills through Reclamation Works (사용종료(使用終了) 비위생매립지(非衛生埋立地)의 순환적(循環的) 사용(使用)을 위한 선별물질(選別物質)의 활용(活用) 가능성(可能性) 평가(評價))

  • Lee, Byung-Sun;Na, Kyung-Duk;Han, Sang-Kuk;Phae, Chae-Gun;Oh, Sae-Eun
    • Resources Recycling
    • /
    • v.21 no.1
    • /
    • pp.17-29
    • /
    • 2012
  • potential assessment of converting closed non sanitary landfills into sustainable landfill through the reclamation works(= landfill mining project) of illegal landfill discovered in land development site using Sustainable Landfill Reclamation system(SLR-system) was investigated. The SLR system had treatment capacity of 91.4 $m^3/hr$ (130.61 ton/hr) in condition of 28.0% of water content. Recovery ratio and purity of sorted soil were 98.9% and 99.66%, respectively. Sorted combustibles were 91.8% and 92.0%, respectively. Especially, high heating value (HHV) and low heating value(LHV) of combustibles were 4,282kcal/kg and 3,636 kcal/kg, respectively, in considering the energy content and recovery ratio of combustibles. Therefore, combustibles separated from landfill site have higher value than Fluff RDF standard value(3,500kcal/kg) of MOE. RDF can be produced with combustibles by 84.43%. Averaged size and organic foreign matter content of the sorted soil were less than 035mm and 0.31 %(VN), respectively. In addition, concentration of all contents of hazardous matters containing soils met safety standards. Therefore, it is possible to be recycled as refilling and cover materials to rebuild Sustainable landfills by 98.42%.

Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content (현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험)

  • Moon, Min-Ho;Yang, So-Yeon;Han, Kuk-Il;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, the fire patterns, heat emissions, and smoke generated by means of fire tests developed for representative combustibles in residential facilities were analyzed from among seven fire types. These combustibles were selected in a previous study to simulate real-world situations and professionalism required while dealing with these types of fires and develop the field commander training content. Consequently, the maximum heat dissipation was recorded as 728.6 kW, followed by the dissipation measured from the combination of a mattress and electric blanket, desk and chair, and TV and mattress. The total heat emission of sofas (226.2 MJ) and the combination of mattress and electric blanket (2,259.5 ㎡) was recorded. In this study, the scope of the tests was limited to the fire characteristics and characteristics of the combustibles, and it is expected that a simulation using various data acquisition methods and FDS would be performed and evaluated at a later stage.

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

Combustion Characteristics of Hydrogen by the Thermodynamic Properties Analysis

  • Han, Sung Bin
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.84-90
    • /
    • 2015
  • Hydrogen has some remarkably high values of the key properties for transport processes, such as kinematic viscosity, thermal conductivity and diffusion coefficient. Hydrogen, as an energy medium, has some distinct benefits for its high efficiency and convenience in storage, transportation and conversion. Hydrogen has much wider limits of flammability in air than methane, propane or gasoline and the minimum ignition energy is about an order of magnitude lower than for other combustibles. Statistical thermodynamics provides the relationships that we need in order to bridge this gap between the macro and the micro. Our most important application will involve the calculation of the thermodynamic properties of the ideal gas.

A Numerical Study of Flame Spread of A Surface Forest Fire (지표화 산불의 화염전파 수치해석)

  • Kim, Dong-Hyun;Lee, Myung-Bo;Kim, Kwang-Il
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.80-83
    • /
    • 2008
  • The characteristics of the spread of a forest fire are generally related to the attributes of combustibles, geographical features, and meteorological conditions, such as wind conditions. The most common methodology used to create a prediction model for the spread of forest fires, based on the numerical analysis of the development stages of a forest fire, is an analysis of heat energy transmission by the stage of heat transmission. When a forest fire breaks out, the analysis of the transmission velocity of heat energy is quantifiable by the spread velocity of flame movement through a physical and chemical analysis at every stage of the fire development from flame production and heat transmission to its termination. In this study, the formula used for the 1-dimensional surface forest fire behavior prediction model, derived from a numerical analysis of the surface flame spread rate of solid combustibles, is introduced. The formula for the 1-dimensional surface forest fire behavior prediction model is the estimated equation of the flame spread velocity, depending on the condition of wind velocity on the ground. Experimental and theoretical equations on flame duration, flame height, flame temperature, ignition temperature of surface fuels, etc., has been applied to the device of this formula. As a result of a comparison between the ROS(rate of spread) from this formula and ROSs from various equations of other models or experimental values, a trend suggesting an increasing curved line of the exponent function under 3m/s or less wind velocity condition was identified. As a result of a comparison between experimental values and numerically analyzed values for fallen pine tree leaves, the flame spread velocity reveals has a error of less than 20%.

  • PDF

A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities (환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구)

  • Jeon, Yong-Han;Han, Sang-Pil
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

A Study of the Suppression System based on the Fire Protection System the Korea Cultural Property due to the Forest Fire -About Water Mist System- (산림화재로부터 문화재를 보호하는 소방시설에 관한 연구 -미분무수설비를 중심으로-)

  • Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.44-51
    • /
    • 2007
  • Most of the Korea temples of cultural property are wooden buildings and easy combusted. They are often located in mountain area far away from the city. It is very difficult to approach the fight area. The putting out is very difficult in the initial fire time. And for protecting the cultural property in the long-term continuous fire source there are some restrictions in water source and suppression system. In this paper the initial putting out fire due to the forest fire and the protection of cultural property in the long-term continuous fire source were researched. The improved project about fire control facilities of the Korea cultural property was proposed. In the proposed project the facilities using Water mist which can reduce more loss than existing facilities using water are applied. In view of the topographic position the method of eliminating the energy of combustibles and wall for cutting off the heat in the fire control facilities are also mentioned.

Fire Identification based on Physical Properties of Bean Oil (대두유의 물리적 특성에 따른 화재감식)

  • Jin, Bog-Kwon;Jung, Soo-Il
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.246-251
    • /
    • 2008
  • Oil Fire easily generates fire in the pressure of the atmosphere and below the normal temperature. Because these discharge flammable gas and ignite within the combustibles limit in conditioning to be assisted air and an invariable density. But Kitchen Fire shows very specific properties of matter and energy Qualification in most cases even though the same oil fires occured. In this Paper, around these specific character that Kitchen Fire have Properties of matter or energy Qualification studied on the genetic mechanism and counter measure scheme.