• Title/Summary/Keyword: Energy of Life

Search Result 4,044, Processing Time 0.033 seconds

Numerical Life Prediction Method for Fatigue Failure of Rubber-Like Material Under Repeated Loading Condition

  • Kim Ho;Kim Heon-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.473-481
    • /
    • 2006
  • Predicting fatigue life by numerical methods was almost impossible in the field of rubber materials. One of the reasons is that there is not obvious fracture criteria caused by nonstandardization of material and excessively various way of mixing process. But, tearing energy as fracture factor can be applied to a rubber-like material regardless of different types of fillers, relative to other fracture factors and the crack growth process of rubber could be considered as the whole fatigue failure process by the existence of potential defects in industrial rubber components. This characteristic of fatigue failure could make it possible to predict the fatigue life of rubber components in theoretical way. FESEM photographs of the surface of industrial rubber components were analyzed for verifying the existence and distribution of potential defects. For the prediction of fatigue life, theoretical way of evaluating tearing energy for the general shape of test-piece was proposed. Also, algebraic expression for the prediction of fatigue life was derived from the rough cut growth rate equation and verified by comparing with experimental fatigue lives of dumbbell fatigue specimen in various loading condition.

Content Analysis of New & Renewable Energy Education in Elementary School Textbooks and Development of Workbook for New & Renewable Energy Education (초등학교 교과서의 신.재생 에너지 교육 내용 분석 및 교재 개발)

  • Chun, Eun-Ju;Choi, Don-Hyung
    • Hwankyungkyoyuk
    • /
    • v.21 no.1
    • /
    • pp.70-81
    • /
    • 2008
  • The purpose of this study is to analyze the status of new & renewable energy education in elementary school textbooks and to develop workbook related new & renewable energy education for elementary school students. The results of this study are as follows. First, in the result of contents analysis energy education and new & renewable energy education through textbooks on 7th elementary school curriculum, subjects including contents related energy are Disciplined Life, Intelligent Life, Moral Education, Social Studies, Science, and Practical Arts. Contents related new & renewable energy are taught $4{\sim}6th$ grades but the quantity and quality of contents are very poor. Second, this study developed workbook related new & renewable energy education for 5th and 6th grades. The workbook is organized with 5 themes that are the need of new & renewable energy, the definition and kinds of new & renewable energy, strengths and weakness of new & renewable energy development, a case of new & renewable energy, and the application of new & renewable energy to practical life. Third, to improve workbook developed, it was applied to 6th grade and then more appropriately modified. Based on the results, it suggests the following for new & renewable energy education. Energy education in elementary school must equally be taught through the all scope of energy education. To solve the energy problem, the content related new & renewable energy education should be included much more both quantity and quality. New & renewable energy education workbook developed in this study is expected to reinforce current textbooks that is being taught a little content of new & renewable energy education.

  • PDF

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

Optimal unidirectional grid tied hybrid power system for peak demand management

  • Vineetha, C.P.;Babu, C.A.
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.47-68
    • /
    • 2016
  • A well designed hybrid power system (HPS) can deliver electrical energy in a cost effective way. In this paper, model for HPS consisting of photo voltaic (PV) module and wind mill as renewable energy sources (RES) and solar lead acid battery as storage device connected to unidirectional grid is developed for peak demand reduction. Life time energy cost of the system is evaluated. One year hourly site condition and load pattern are taken into account for analysing the HPS. The optimal HPS is determined for least life time energy cost subject to the constraints like state of charge of the battery bank, dump load, renewable energy (RE) generation etc. Optimal solutions are also found out individually for PV module and wind mill. These three systems are compared to find out the most feasible combination. The results show that the HPS can deliver energy in an acceptable cost with reduced peak consumption from the grid. The proposed optimization algorithm is suitable for determining optimal HPS for desired location and load with least energy cost.

A Study on the Various Characteristics of Ultrasonic-Energy-Added W/O Type Emulsified Fuel (II) - attaching importance to micro-explosion of single droplet and chemical characteristics - (초음파에너지 조사 W/O type 유화연료의 제반특성에 관한 연구(II) - 단일액적 미소폭발 및 화학적 특성을 중심으로 -)

  • Kim, Yong-Cheol;Han, Keun-Hee;Ryu, Jeong-In
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.29-34
    • /
    • 2004
  • To investigate characteristics and micro-explosion of single-droplets of emulsified fuel, water is mixed with diesel oil by using ultrasonic energy fuel feeding system. The fuel characteristics is analysed through H-NMR spectrum and micro-explosion phenomena of the emulsified fuel is also investigated. The life times of droplets of conventional diesel fuel, ultrasonic energy added diesel fuel and emulsified fuel we obtained additionally. According to this study, the micro-explosion phenomena of single-droplets happen in atmospheric pressure condition, a curve form of emulsified fuel's life tim is different from diesel fuel's one and the change of chemical structures is a cause of ultrasonic-energy-added diesel fuel effect.

  • PDF

Life Cycle Assessment (LCA) and Energy Efficiency Analysis of Fuel Cell Based Energy Storage System (ESS) (연료전지 기반 에너지저장 시스템의 환경 전과정평가 및 에너지 효율성 분석)

  • KIM, HYOUNGSEOK;HONG, SEOKJIN;HUR, TAK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.156-165
    • /
    • 2017
  • This study quantitatively assessed the environmental impacts of fuel cell (FC) systems by performing life cycle assessment (LCA) and analyzed their energy efficiencies based on energy return on investment (EROI) and electrical energy stored on investment (ESOI). Molten carbonate fuel cell (MCFC) system and polymer electrolyte membrane fuel cell (PEMFC) system were selected as the fuel cell systems. Five different paths to produce hydrogen ($H_2$) as fuel such as natural gas steam reforming (NGSR), centralized naptha SR (NSR(C)), NSR station (NSR(S)), liquified petroleum gas SR (LPGSR), water electrolysis (WE) were each applied to the FCs. The environmental impacts and the energy efficiencies of the FCs were compared with rechargeable batteries such as $LiFePO_4$ (LFP) and Nickel-metal hydride (Ni-MH). The LCA results show that MCFC_NSR(C) and PEMFC_NSR(C) have the lowest global warming potential (GWP) with 6.23E-02 kg $CO_2$ eq./MJ electricity and 6.84E-02 kg $CO_2$ eq./MJ electricity, respectively. For the impact category of abiotic resource depletion potential (ADP), MCFC_NGSR(S) and PEMFC_NGSR(S) show the lowest impacts of 7.42E-01 g Sb eq./MJ electricity and 7.19E-01 g Sb eq./MJ electricity, respectively. And, the energy efficiencies of the FCs are higher than those of the rechargeable batteries except for the case of hydrogen produced by WE.

Estimation of Carbon Emissions and Energy Self-Sufficiency in Sewage Treatment plant's Improvement by using Life Cycle Management Tool (LCM 기법을 이용한 하수처리장 개선에 따른 탄소배출량 및 에너지 자립율 평가)

  • Moon, Jin-Young;Park, Ji-Hyoung;Hwang, Yong-Woo;Park, Kwang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.223-232
    • /
    • 2013
  • In this study, carbon emissions and energy consumption were evaluated to establish a design strategy which has low energy consumption and carbon emission production, by using life cycle energy (LCE) and life cycle $CO_2(LCCO_2)$ calculation methods in life cycle management(LCM) tools. After improvement design projects, the energy consumption and $CO_2$ emission were calculated and compared in three sewage treatment plants (STPs), which are A STP, B STP, and C STP. The reduction of carbon emissions was 28,020.1 ton $CO_{2-}e/yr$, 37,399.6 ton $CO_{2-}e/yr$ and 8,788.3 ton $CO_{2-}e/yr$, respectively. Production of energy was 792 TOE/yr, 1,235 TOE/yr and 1,023 TOE/yr, respectively. As a result, the estimation of energy and energy self-sufficiency was 5.1 %, 14.5 % and 23.5 %, respectively. The result of this study shows the LCM can be contributed to establish strategy for energy and carbon emission reduction in sewage treatment plants.

Prediction of Low Cycle Fatigue Life for Inconel 617 using Strain Energy Method (변형률 에너지법을 이용한 Inconel 617의 저주기피로 수명 예측)

  • Kim, Duck-Hoi;Kim, Ki-Gwang;Kim, Jae-Hoon;Lee, Young-Shin;Park, Won-Sik
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.285-290
    • /
    • 2004
  • Low cycle fatigue tests are performed on the Inconel 617 that be used for a hot gas casing. The relation between strain energy density and numbers of cycles to failure is examined in order to predict the low cycle fatigue life of Inconel 617. The life predicted by the strain energy method is found to coincide with experimental data and results obtained from the Coffin-Manson method. Also the cyclic behavior of Inconel 617 is characterized by cyclic hardening with increasing number of cycle at room temperature.

  • PDF

A Comparison of Embodied Energy and Environmental Impact on the New Building and Remodelling of Construction Types in Apartment Housing (공동주택의 신축공사와 리모델링 공사에 공종별 에너지 소비량 및 환경영향 비교 연구)

  • 이강희
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.65-74
    • /
    • 2003
  • Recently, the environmental conservation has been emphasized over the world. Building industry should carefully reflected the development focused on the economic aspect as well as the environmental considerations. Therefore, it requires the technology development to mitigate the environmental pollution through the reducement of the energy and resources usage amount over the building life cycle. For these, it should be required to set up the analysis methodology to grasp the amount of the environmental pollution and energy and resources in each step of building life cycle. In this paper, it aimed at preparing the analysis process and analyzing the embodied energy and $CO_2$ and $SO_x$ emission according to the building work, field work, mechanical and electrical work on the new building and remodelling, utilizing the inventory analysis which is one of the LCA process.