• Title/Summary/Keyword: Energy meter

Search Result 362, Processing Time 0.031 seconds

Performance Analysis of Electricity Demand Forecasting by Detail Level of Building Energy Models Based on the Measured Submetering Electricity Data (서브미터링 전력데이터 기반 건물에너지모델의 입력수준별 전력수요 예측 성능분석)

  • Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.627-640
    • /
    • 2018
  • Submetering electricity consumption data enables more detail input of end use components, such as lighting, plug, HVAC, and occupancy in building energy modeling. However, such an modeling efforts and results are rarely tried and published in terms of the estimation accuracy of electricity demand. In this research, actual submetering data obtained from a university building is analyzed and provided for building energy modeling practice. As alternative modeling cases, conventional modeling method (Case-1), using reference schedule per building usage, and main metering data based modeling method (Case-2) are established. Detail efforts are added to derive prototypical schedules from the metered data by introducing variability index. The simulation results revealed that Case-1 showed the largest error as we can expect. And Case-2 showed comparative error relative to Case-3 in terms of total electricity estimation. But Case-2 showed about two times larger error in CV (RMSE) in lighting energy demand due to lack of End Use consumption information.

Near-infrared Laser Energy Transmission through Teeth with Crack Lines: An In-vitro Study

  • Sapra, Ashita;Darbar, Arun;George, Roy
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.214-219
    • /
    • 2021
  • Background and Objectives To evaluate the difference in near-infrared (810 nm) laser energy transmission through teeth with and without cracks. Materials and Methods Extracted teeth were sectioned and examined visually for the presence of cracks with the aid of photographs and a trans-illuminator. Fourteen sections, each with cracks (Group A) and no cracks (Group B) were identified and placed 15 mm from the tip of a 300 micron fiber, prior to activation with an 810 nm diode laser (0.1W, 50 ms interval,100 ms duration). A power meter positioned behind the tooth recorded the average energy that was transmitted through the samples. Unpaired t-test analysis was used to determine if the tooth sections with cracks allowed higher power passage compared to sound teeth. Results The mean power recording for the cracked teeth (Group A) was significantly greater (p = 0.0005) than that for the non-cracked teeth (Group B). Conclusion Within the limitations of this study, it is evident that significantly higher laser energy passes through teeth with cracks in comparison to teeth without cracks. A recent clinical study has also shown that lasers could be used to assess symptomatic cracked teeth. Hence, further research is required to determine the relative increase in energy required to identify symptomatic cracked teeth.

An Improved Estimation Model of Server Power Consumption for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 향상된 서버 전력 소비 추정 모델)

  • Kim, Dong-Jun;Kwak, Hu-Keun;Kwon, Hui-Ung;Kim, Young-Jong;Chung, Kyu-Sik
    • The KIPS Transactions:PartA
    • /
    • v.19A no.3
    • /
    • pp.139-146
    • /
    • 2012
  • In the server cluster environment, one of the ways saving energy is to control server's power according to traffic conditions. This is to determine the ON/OFF state of servers according to energy usage of data center and each server. To do this, we need a way to estimate each server's energy. In this paper, we use a software-based power consumption estimation model because it is more efficient than the hardware model using power meter in terms of energy and cost. The traditional software-based power consumption estimation model has a drawback in that it doesn't know well the computing status of servers because it uses only the idle status field of CPU. Therefore it doesn't estimate consumption power effectively. In this paper, we present a CPU field based power consumption estimation model to estimate more accurate than the two traditional models (CPU/Disk/Memory utilization based power consumption estimation model and CPU idle utilization based power consumption estimation model) by using the various status fields of CPU to get the CPU status of servers and the overall status of system. We performed experiments using 2 PCs and compared the power consumption estimated by the power consumption model (software) with that measured by the power meter (hardware). The experimental results show that the traditional model has about 8-15% average error rate but our proposed model has about 2% average error rate.

The Valuation of HSA Business Using Broadband over Power Line (전력선통신망을 이용한 HSA사업의 경제적 타당성 분석)

  • Lyoo, Tae-Ho;Kim, Chang-Seob
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.202-214
    • /
    • 2007
  • The concept of HSA (Home Service Aggregator) is derived from performing the energy IT business efficiently as well as successfully launcing a new service based on BPL (Broadband over Power Line). The HSA business using a BPL can extend the field of energy industry and an give a chance to create a new demand by consumer-oriented services. This study focuses on the exact evaluation of HSA business using BPL, and reasonable trusty evaluation should be the first step to launch the HSA business. In this study, the categories of cost are comprised of equipment (mainly RSM and MGW) cost, instalation cost, and maintenance cost. AMR (Automatic Meter Reading), internet integration billing service, integration charging service, internet service, sorority service, and electricity safety are listed for benefit. In this study, the ROI of HSA business is 0.9594, which is less than 1. However, that value does not consider the electricity safety benefit which is classified as a social benefit. Therefore, the value can be above 1 if it includes social and private benefits.

Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis - (맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 -)

  • Kim, Gyeong-Cheal;Lee, Jeong-Won;Ryu, Kyeong-Ho;Park, Dong-Il;Shin, Woo-Jin;Kang, Hee-Jung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.

Smart Information Monitoring Technology (스마트 정보 모니터링 기술)

  • Kang, Man-Mo;Lee, Dong-Hyung;Koo, Ja-Rok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.225-233
    • /
    • 2010
  • Recently, in the field of Smart Grid, Smart Home Network, Ubiquitous Computing, etc. we have continued to study Smart Information Monitoring Technology(SIMT) which exchange, control and monitor information collected and processed by need in real-time and two-way. In this paper, we understand application products or recent trends of SIMT for Energy, U-Farm, Vehicle Information and Home Network. Specially, we explain Google PowerMeter which exchange information with Smart Meter of core part of the smart grid at real-time, Real-time Monitoring System(RMS) for U-Farm, RMS for vehicle status Information. we subscribe Smart Information Monitoring Technology application based on ZigBee of low price, low power or related work. Finally we subscribe actual proof construction situation of Jesu for smart grid.

A Real-Time Demand Response Management Using Smart Box (스마트 박스를 활용한 실시간 수요관리)

  • Ko, Dong-Kwan;Bea, Jun-Cheol;Min, Kyoung-Chon;Lee, Jae-Kyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • The Demand Response Market is a nation-wide power and energy management program of electric power demand response operated by KPX (Korea Power eXchange). Therefore, any savings could be determined by KEPCO's AMR(Automatic Meter Reading) data. However, the customers and the service providers participating in the market could not know the real time value due to the 15 minute or even more delayed AMR data communicated. Here, a new concept of a smart box has been introduced and demonstrated to provide the real time saving values compared to the current KEPCO's AMR data approach.

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

An Efficient AMI Simulator Design adapted in Smart Grid (스마트그리드에서의 효율적인 AMI 구현을 위한 통합 시뮬레이터 설계)

  • Yang, Il-Kwon;Choi, Seung-Hwan;Lee, Sang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1368-1375
    • /
    • 2013
  • The Smart Grid, which can monitor or diagnose the power grid in real time to operate efficiently, has been pushed ahead systematically as one of alternatives to solve these issues by combining the advanced Information Communication Technology and the electrical network. Hence, the electric company which introduces smart grid technology can read remotely the electrical meter readings by means of two-way communication between the meter and the central system. This enabled the customer and the utility to take part in reasonable electrical energy utilization. AMI became one of the core foundations in realizing the Smart Grid. It is hard to test the entire process of AMI system before the full deployment because it covers the broad objects from the customer to the utility operation system and requires mass data handling and management. Therefore, we design an efficient AMI network model and a simulator for performance evaluation required to simulate the network model similar to the real environment. This tool supports to evaluate the efficiency of the AMI network equipments and deployment. Additionally, it estimates the appropriate number of deployments and the proper capabilities.

Attacks, Vulnerabilities and Security Requirements in Smart Metering Networks

  • Hafiz Abdullah, Muhammad Daniel;Hanapi, Zurina Mohd;Zukarnain, Zuriati Ahmad;Mohamed, Mohamad Afendee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.4
    • /
    • pp.1493-1515
    • /
    • 2015
  • A smart meter is one of the core components in Advanced Metering Infrastructure (AMI) that is responsible for providing effective control and monitor of electrical energy consumptions. The multifunction tasks that a smart meter carries out such as facilitating two-way communication between utility providers and consumers, managing metering data, delivering anomalies reports, analyzing fault and power quality, simply show that there are huge amount of data exchange in smart metering networks (SMNs). These data are prone to security threats due to high dependability of SMNs on Internet-based communication, which is highly insecure. Therefore, there is a need to identify all possible security threats over this network and propose suitable countermeasures for securing the communication between smart meters and utility provider office. This paper studies the architecture of the smart grid communication networks, focuses on smart metering networks and discusses how such networks can be vulnerable to security attacks. This paper also presents current mechanisms that have been used to secure the smart metering networks from specific type of attacks in SMNs. Moreover, we highlight several open issues related to the security and privacy of SMNs which we anticipate could serve as baseline for future research directions.