• Title/Summary/Keyword: Energy linearity

Search Result 251, Processing Time 0.028 seconds

Mechanical Properties of Synthetic Fabrics Dyed with Persimmon juice (감즙 염색에 의한 합성직물의 역학적 특성)

  • Bae, Jung-Sook;Huh, Man-Woo
    • Textile Coloration and Finishing
    • /
    • v.28 no.2
    • /
    • pp.109-117
    • /
    • 2016
  • Synthetic fabrics, such as nylon and polyester, were dyed with persimmon juice by using a padding mangle repeatedly. The mechanical properties of these synthetic fabrics were analyzed using the Kawabata evaluation system. The following findings were obtained from this investigation. As the number of repetitions of padding dyeing increased, the tensile energy per unit area and the tensile resilience of synthetic fabric remained almost unchanged, whereas the linearity of the load-extension curve of the synthetic fabrics increased. As the number of padding repetitions increased, the synthetic fabrics dyed with persimmon juice exhibited increases in thickness and weight. As the number of repetitions of padding treatment with persimmon juice increased, the values of stiffness, anti-drape stiffness, fullness, and softness also increased, whereas the flexibility with soft feeling, crispness, and scrooping sensation significantly decreased. The amount of coated persimmon juice on the surface of the fabrics increased after three repetitions of padding treatment with persimmon juice. Nylon and polyester fabrics were dyed evenly with persimmon juice treated using a padding mangle.

Design of a CMOS D/A Converter for advanced wireless transceiver of high speed and high resolution (고속 고해상도의 무선통신 송 $\cdot$ 수신기용 CMOS D/A 변환기 설계)

  • Cho Hyun-Ho;Park Cheong-Yong;Yune Gun-Shik;Ha Sung-Min;Yoon Kwang-Sub
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.549-552
    • /
    • 2004
  • The thesis describes the design of 12bit digital-to-analog converter (DAC) which shows the conversion rate of 500MHz and the power supply of 3.3V with 0.35${\mu}m$ CMOS 1-poly 4-metal process for advanced wireless transceiver of high speed and high resolution. The proposed DAC employes segmented structure which consists of 6bit MSB, 3bit mSB, 3bit LSB for area efficiency Also, using a optimized aspect ratio of process and new triple diagonal symmetric centroid sequence for high yield and high linearity. The proposed 12bit current mode DAC was employs new deglitch circuit for the decrement of the glitch energy. Simulation results show the conversion rate of 500MHz, and the power dissipation of 85mW at single 3.3V supply voltage. Both DNL and INL are found to be smaller than ${\pm}0.65LSB/{\pm}0.8LSB$.

  • PDF

Determination of Iodide in Sulfuric Acid Aqueous Solution by the Ion Chromatography with UV Detection (이온 크로마토그래피와 자외선 검출을 이용한 황산수용액 중의 요오드 음이온 정량)

  • Park, Yang-Soon
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.306-310
    • /
    • 2001
  • Ion chromatography was applied to determine iodide remained in sulfuric acid aqueous solution after adsorption procedure. Iodide was determined in 0.25 M, 0.5 M and 1 M sulfuric acid solution on time variation. Because sulfuric acid in solution plays as an oxidizer, the concentration of iodide decreased with increasing concentration or sulfuric acid. Thereafter, sulfuric acid was neutralized with sodium hydroxide. Good linearity(r=0.99999) was obtained at the range of 0-20 mg/L 1 in 0.5 M sodium sulfate matrix.

  • PDF

The Construction of Solid State Detector System Using Commercially Available Diode and Its Application (정류기형 다이오드를 이용한 반도체 방사선 검출 장치의 제작과 그 응용에 관한 연구)

  • 신동오;홍성언;이병용;이명자
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.91-95
    • /
    • 1990
  • The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy

  • PDF

Design of High-efficiency Power Amplifier System for High-directional Speaker (고지향성 스피커를 위한 새로운 전력 증폭기 설계)

  • Kim, Jin-Young;Kim, In-Dong;Moon, Wonkyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1215-1221
    • /
    • 2017
  • Parametric array transducers are used for highly directional speaker in an air environments. Piezoelectric micromachined ultrasonic transducers for parametric array transducers need DC-biased voltage driving signals in order to get high-directional quality-sound features. The existing power amplifier such as class A amplifiers has low efficiency and require large volume heatsinks. To overcome the above-mentioned disadvantages of the conventional amplifier, this paper proposes a new power amplifier system. The proposed power amplifier system ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier. Furthermore, the proposed power amplifier system gets high efficiency because it contains the DC-DC converter-type power supply which can perform energy recovery and envelope tracking function. Also the paper suggests the detailed circuit topology. Its characteristics are verified by the detailed experimental results.

A Study on the Improvement of Flow Characteristics of the Glove Valve for Compressible Fluid (압축성 유체용 글로브 밸브의 유량특성 향상에 관한 연구)

  • Bae, Ji Won;Chung, Woo Young;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.32-37
    • /
    • 2019
  • Glove valves are used for various purposes in the process control field because such valves enable easy control of temperature and pressure. However, such valves are associated with significant loss of pressure and also have the disadvantage of complicating the shape of the cage or plug to facilitate linear flow rate change. In this paper, the shape of the plug, one of the valve flow control elements, was designed to improve the flow characteristics of the glove valve, and then CFD analysis was performed using compressible fluid. The numerical analysis results of the glove valve were analyzed according to the opening ratio and the pressure ratio of the valve. From these results, it was found that the proper notch on the side of the plug contributed to reducing the energy loss of the fluid through the valve and improving the linearity of the valve.

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

The Evaluation of Multiplane-Parallel Chamber Using Crystal Plate as Ionization Medium for Therapeutic Radiation Beams

  • Young W. Vahc;Park, Kyung R.;Kim, Sookil;Chul W. Joh;Kim, Tae H.
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • There has been necessity of an air free ionization chamber using the gold-crystal-aluminium plates, henceforth called the crystal chamber. The crystal chamber formed of parallel plates is very small in size and has more response for absorbed dose of therapeutic radiation beams. The gold plate on the crystal facing the photon and electron beam acts as an intensifier of signals and crystal plate as an ionization medium respectively. Both the copper guard ring and the aluminum collecting electrode are connected to an electrometer. Using high energy photon (6, 15 MV) and electron (9, 12, 15, 18 MeV) beams, the responses of the crystal chamber are evaluated against a PTW Farmer-type chamber at a field size of 10${\times}$10cm$^2$ and 100 cm SSD. The responses of crystal chamber for therapeutic radiation electron and photon beams are greater in magnitude by several order than Farmer. The crystal chamber has good linearity without correction factor C$\_$t,p/ with respect to the signals, a reading reproduction with good accuracy and precision less than 0.5%, and has other useful functions in measuring radiation beams.

  • PDF

Effect of Cellulase Treatment on Mechanical Properties and Hand of Tencel Fabrics (효소처리에 의한 텐셀직물의 역학적 성질 및 태의 변화)

  • 손경희;신윤숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1141-1149
    • /
    • 1998
  • Tencel fabrics were treated with NaOH, mechanically prefibrillated, and hydrolyzed by cellulase. Softner was applied to improve hand of the treated Tencel fabrics after prefibrillation and cellulase treatment. Kawabata's Evaluation System for Fabrics(KES-FB) was used to evaluate effects of NaOH pretreatment, prebifrillation, and cellulase and softner treatments on fabric hand of the treated fabrics. Primary hand values of women's medium thick fabrics such as KOSHI, NUMERI, FUKURAMI, and SOFUTOSA, and total hand values were evaluation parameters. As the treatments of prefibrillation, cellulase, and softner progressed, values in bending and shearing properties decreased and softness and elasticity were imparted to the treated fabrics. Specifically, compressional linearity, compressional energy, and thickness of the treated fabrics increased by prefibrillation, providing bulkiness to the treated fabrics. Values indicating surface properties increased owing to fibrils formed by prefibrillation treatment, but removal of fibrils by cellulase treatment enhanced smoothness. As the fabrics were exposed to various treatments such as NaOH pretreatments, prefibrillation, and cellulase and softner treatments, NUMERI, FUKURAMI, SOFUTOSA, and total hand values increased with the exception of KOSHI, Consequently, the treated fabrics became softer, smoother, and more elastic. Especially, the NaOH pretreatment provided superior SOFUTOSA to Tencel fabrics.

  • PDF

Investigation of Characteristics of Waves Generated in Two-Dimensional Wave Channel (2차원 조파수조에서의 파 생성 특성 조사)

  • Ahn, Jae-Youl;Choi, Jung-Kyu;Kim, Hyoung-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.68-75
    • /
    • 2013
  • This paper investigates the characteristics of waves generated by a flap-type wave maker in a two-dimensional wave channel. Measurements are carried out for various water depths, wave heights, periods, and lengths capacitance-type wave height gages. The experimental results are shown to satisfy the dispersion relation of the linear wave theory. For waves with a small height and long period, the wave profiles agree well with those of the linear wave theory. However, as the wave height and period become higher and shorter, respectively, it is shown that the wave profiles measured in the present experiments are different from the linear wave profiles, and the measured wave heights are smaller than the target wave heights, which may be due to the non-linearity of the waves. As the wave progresses toward the channel end, the wave height gradually decreases. This reduction in the wave height along the wave channel is explained by the wave energy dissipation due to the friction of the side walls of the channel. The performance of the wave absorber in the channel is found to be acceptable from the results of the wave reflection tests.