• 제목/요약/키워드: Energy estimation

검색결과 2,220건 처리시간 0.1초

Pre-filtering and Location Estimation of a Loose Part

  • Kim, Jung-Soo;Kim, Tae-Wan;Joon Lyou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.522-522
    • /
    • 2000
  • In this paper, two pre-filtering techniques are presented for accurately estimating the impact location of a loose part. The reason why a pre-filterng technique Is necessary in a Loose Part Monitoring System is that the effects of background noise on the signal to noise ratio (SNR) can be reduced considerably resulting in improved estimation accuracy. The first method is to take d moving average operation in the time domain. The second one is to adopt band-pass filters designed in the frequency domain such as a Butterworth filter, Chebyshev filter I & II and an Elliptic Filter. To show the effectiveness, the impact test data (signals) from the YGN3 power plant are first preprocessed and then used to estimate the loose pan impact position. Resultantly. we observed that SNR is much improved and the average estimation error is below 7.5%.

  • PDF

축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정 (Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships)

  • 정태영;정석권
    • 동력기계공학회지
    • /
    • 제14권1호
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.

국가바람지도에 의한 풍력자원 잠재량 산출방법 (Estimation Method of Wind Resource Potential Using a National Wind Map)

  • 김현구;장문석;김은일;이화운;이순환;김동혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.332-333
    • /
    • 2008
  • This paper presents an estimation method of national wind resource potential using a national and GIS(Geographical Information System). The wind resource potential is classified into theoretical, geographical and technical potentials and each category narrows down the previous definition by excluding impossible area to be developed as a wind farm using GIS datasets for onshore and offshore. As a basic unit of wind energy potential at a certain area, API(Average Power Intercepted) is calculated from WPD(Wind Power Density) given by a national wind map which is established by numerical wind simulation, so that a logical and relatively accurate potential estimation is possible comparing with other methods based on a field measurement interpolation which is inevitable to avoid critical assumptions.

  • PDF

Smart Air Condition Load Forecasting based on Thermal Dynamic Model and Finite Memory Estimation for Peak-energy Distribution

  • Choi, Hyun Duck;Lee, Soon Woo;Pae, Dong Sung;You, Sung Hyun;Lim, Myo Taeg
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.559-567
    • /
    • 2018
  • In this paper, we propose a new load forecasting method for smart air conditioning (A/C) based on the modified thermodynamics of indoor temperature and the unbiased finite memory estimator (UFME). Based on modified first-order thermodynamics, the dynamic behavior of indoor temperature can be described by the time-domain state-space model, and an accurate estimate of indoor temperature can be achieved by the proposed UFME. In addition, a reliable A/C load forecast can be obtained using the proposed method. Our study involves the experimental validation of the proposed A/C load forecasting method and communication construction between DR server and HEMS in a test bed. Through experimental data sets, the effectiveness of the proposed estimation method is validated.

우편집중국 수변전 설비 수용률 산정을 위한 새로운 부하 계산법 개발 (Development of a Novel Load Capacity Estimation Method for Demand Factor Calculation of a Mail Center)

  • 윤순만;정종찬;김광호
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.3-8
    • /
    • 2010
  • Recently, There have been many attempts to optimize energy usage in buildings and houses using Information Technology(IT) and the typical implementation can be found in Intelligent Building and Zero Energy Building. These kinds of buildings need to forecast the building loads, estimate the capacity requirement for power supply, and decide the capacity of the main transformer of the building. Currently, the capacity of the main transformer has been decided just using typical load estimation method not considering the load characteristics and patterns. In this paper, we propose a new load estimation method considering the load characteristics and patterns of the builiding. The proposed method was applied to actual mail center and verified the feasibility of application to actual design of buildings.

  • PDF

플라이애시와 고로슬래그를 조합 사용한 초지연 콘크리트의 강도증진 (Estimation of the Strength Development of the Super Retarding Concrete Incorporating Fly Ash and Blast Furnace Slag)

  • 한민철
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.119-125
    • /
    • 2008
  • In this paper, the estimation of super retarding concrete incorporating mineral admixtures at the same time including fly ash(FA), blast furnace slag(BS) are studied based on maturity method. The setting time was retarded, as super retarding agent contents increase and curing temperature decreases. In addition, apparent activation energy by Arrhenius function was ranged from $24\sim35$ KJ/mol with slightly difference along with mixture proportion. This value is smaller than existing value $30\sim50$ KJ/mol. Based on strength development estimation. it exhibited comparable relativity between prediction value and measurement value. Therefore, this study provided effective strength development prediction value with super retarding agent contents and mineral admixture combination. Strength development prediction equation provided herein is possibly valid for estimating accurate strength development of the super retarding concrete at the job site.

전력변환기에 대한 직류링크 커패시터의 고장진단을 위한 간단한 용량 추정 기법 (A Simple Capacitance Estimation Method for Failure Diagnosis of DC Link Electrolytic Capacitor in Power Converters)

  • 손진근;김동준
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.378-383
    • /
    • 2010
  • Due to the large capacity and low cost, DC link electrolytic capacitors with of energy storage and voltage regulation are used for almost all types of power converter as the DC/AC inverter or DC/DC converter. Electrolytic capacitor, which is the most of the time affected by the aging effect, plays very important role for the power converter system quality and reliability. Therefore, this paper proposes a simple method to estimate the capacitance variation of an electrolytic capacitor in order to analyze the internal characteristic decrease and worn-out state of an electrolytic capacitor. Simulation results by using capacitor storage energy computation show the validity of the proposed capacitance estimation method.

물-에너지 넥서스기반 국내 댐 가능최대 수열에너지 산정 (Estimation of the Probable Maximum Water Thermal Energy in Korean Dams based on the Water-Energy Nexus Concept)

  • 정영훈
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.45-53
    • /
    • 2018
  • Demand for essential resources including water, energy and food is rapidly increasing due to climate change, population growth and urbanization. To solve this problem, the concept of water-energy-food nexus has been introduced, and many countries have been trying to acquire the Nexus technology that can maximize the efficiency by analyzing the interconnection between resources. In this regard, this study attempted to estimate the probable maximum water thermal energy in the dam based on the water-energy nexus concept. The estimation of the probable maximum water thermal energy was implemented to monthly water storage of the largest dams in the four major river systems. As a result of analyzing the estimated monthly water thermal energy from 2000 to 2016, Soyang River dam has the largest probable maximum water thermal energy, and Sumjin River dam has the smallest. However, the probable maximum water thermal energy was small in common between March and April, between September and October due to the small temperature difference between the ambient air and the dam water. Also, according to the characteristics of the dam, Daecheong dam and Soyang River dam were beneficial for supplying water thermal energy for heating, and Sumjin River dam and Andong dam were advantageous for supplying water thermal energy for cooling. Our findings can be useful to realize the water-energy-food nexus by increasing the utilization and value of water resources as well as expanding the roles and functions of dams as a starting point to use dam water thermal energy.

계측기기 측정을 통한 생활폐기물 소각시설의 에너지 회수효율 산정 연구 (Estimation of Energy Recovery Rate of Municipal Waste Incineration Facilities through Measuring Instruments)

  • 권영현;강준구;고영재;유하녕;권준화;박호연;전태완;이영기
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.770-776
    • /
    • 2018
  • This study measured the energy recovery rate of each municipal waste incineration facility according to the revised energy recovery rate estimation method, which targeted four municipal waste incineration facilities (Unit No. 7). The results calculated by the measuring instruments were used for each factor to estimate the recovery rate, and the available potential of available energy was examined by analyzing the energy production and valid consumption. As a result of the low heating value, 2,540 kcal/kg was calculated on average when the LHVw formula was applied, which is approximately 116 kcal/kg higher than the average design standard of 2,424 kcal/kg. The energy recovery rate was calculated as 96.9% on average based on production and 67.5% based on effective consumption, and the analysis shows that approximately 29.4% energy can be used.

Estimation of Plastic Energy Dissipation Amount of Multi-bent Spatial structure by Equivalent Linear Analysis

  • 이승재
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.131-136
    • /
    • 2006
  • It is important to evaluate energy absorption capacity of frames required during a design earthquake. An inelastic computer analysis based on mathematical modelling of energy absorbing frames and elements makes it possible to evaluate required energy absorption capacity. But such an analysis sometimes consumes much computation time particularly in case of complicated structural system. This paper presents a proposal to predict energy absorption of multi-bent steel frames by simple equivalent linear method.

  • PDF