• Title/Summary/Keyword: Energy efficiency potential

Search Result 668, Processing Time 0.026 seconds

A Study on Establishing Infrastructure Plans to Introduce an Energy Efficiency Resource Standards - Based on the Energy Demand Side Management and Energy Efficiency Potential - (에너지효율향상의무화제도의 국내 도입을 위한 기반구축 연구 - 에너지수요관리제도 및 절감률 산정 중심으로 -)

  • Hong, Sung-Jun;Choi, Bong-Ha;Lee, Deok-Ki;Park, Soo-Uk;Won, Jong-Ryul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.241-247
    • /
    • 2010
  • An Energy Efficiency Resource Standards (EERS) is a simple, market-based mechanism to encourage more efficient generation, transmission, and use of electricity, natural gas and heat. An EERS consists of electric, gas and/or heating energy savings targets for utilities, often with flexibility to achieve the target through a market-based trading system. In this paper, we make persons acquainted with EERS programs of foreign countries in these days. And we analyze domestic energy demand side management (DSM) programs in order to introduce an EERS program into the country successfully. Energy efficiency potential calculated in 2007 is one of the important factors for establishing an EERS program domestically. This study may provide basic data to set the amount of energy saving when an EERS program would be phased in.

Analysis of standby power for enhancing the energy efficiency of a hotel guestroom - Focusing on check-out status - (호텔 객실의 에너지 효율화를 위한 대기전력 분석 - 체크아웃 상태를 중심으로 -)

  • Lee, Junsoo;Koo, Choongwan
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2022
  • The issue of hotel energy use is growing more significant as the hotel industry expands. It is important to take into account the electrical installation and space-specific features in a room unit in order to comprehend the energy consumption of a hotel guestroom. In light of this, this study aimed to analyze standby power for enhancing the energy efficiency of a hotel guestroom during check-out status. This study was conducted in three steps: (i) data collection; (ii) analysis of energy consumption patterns; and (iii) analysis of energy efficiency improvement plan. The main findings of this study can be summarized as follows. First, 32.24% of energy was used in fan coil unit) during check-out status. Second, a hotel guestroom had a 4.30% energy saving potential, based on energy consumption patterns during check-out status. This study can contribute to support hotel management to operate guestrooms differently by helping them identify patterns in energy use and realize potential savings.

Mobile application to evaluate existing university buildings using building information

  • Chung, Min-Hee
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.13-20
    • /
    • 2016
  • Purpose: The purpose of this study is to provide information on building's energy consumption and efficiency for general building users through a mobile application. Method: This paper presents a mobile application process and building energy assessment models for general users to understand easily. There are two assessment models, one is based on the energy consumption. The other is based on the architectural planning factors of a building. The assessment models are proposed to understand buildings' energy efficiency and to compare the energy consumption level for general users. The applicability of proposed application has been evaluated by conducting a case study. The case study is targeting university buildings. Result: Energy efficiency potentials were proposed using weighting factor which was calculated by the impact on energy consumption of a building according to parameters. The mobile application used the simple energy assessment model by energy efficiency potentials and was developed for a smartphone By using the mobile application, numerous general users of smartphones can easily and conveniently access information pertaining to buildings, energy consumption, and reductions in energy consumption. The proposed application enables user to find more energy efficient buildings by comparing energy status and energy efficiency potential by given information.

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

Estimating Potential Energy Consumption and Carbon Emission Reduction in South Korea Using Non-radial Data Envelopment Analysis Approach (Non-radial Data Envelopment Analysis를 적용한 지역별 에너지 및 이산화탄소 저감가능성 추정)

  • Kim, Kwang-Uk;Kang, Sang-Mok
    • Environmental and Resource Economics Review
    • /
    • v.25 no.2
    • /
    • pp.299-320
    • /
    • 2016
  • This study estimates an energy efficiency of 16 metropolitans and provinces in Korea, and measures potential energy-saving and carbon emission reduction using a non-radial data envelopment analysis method. Based on energy mix scenarios, this study also evaluates the impact of changes in energy structural adjustment on a regional environmental performance. The empirical results show that, on average, 12.70% of energy consumption and 13.73% of carbon emission can be reduced by improvement in energy efficiency, and low efficiency of oil usage in metropolitan cities is a major source of the inefficiency. Furthermore, it is found that energy mix policy should be considered to achieve an extra energy-saving and carbon reduction.

Fluctuation in operational energy efficiency of ships and its implications for performance appraisal

  • Zhang, Shuang;Yuan, Haichao;Sun, Deping
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.367-378
    • /
    • 2021
  • This paper develops a dynamic regression model to quantify the contribution of key external factors to operational energy efficiency of ships. On this basis, kernel density estimation is applied to explore distribution patterns of fluctuations in operational performance. An empirical analysis based on these methods show that distribution of fluctuations in Energy Efficiency Operational Indicator (EEOI) is leptokurtic and fat tailed, rather than a normal one. Around 85% of fluctuations in EEOI can be jointly explained by capacity utilization and sailing speed, while the rest depend on other external factors largely beyond control. The variations in capacity utilization and sailing speed cannot be fully passed on to the energy efficiency performance of ships, due to complex interactions between various external factors. The application of the methods is demonstrated, showing a potential approach to develop a rating mechanism for use in the legally binding framework on operational energy efficiency of ships.

A study of energy consumption and savings potential in wired network equipment (유선 네트워크 장비의 에너지 소모량과 절약 잠재성 연구)

  • Kim, Ki-Young;Suh, Yu-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6469-6477
    • /
    • 2013
  • As the Internet has grown, energy consumption and GHG emission from internet use have become issues in recent years. On the other hand, such interest in greening the Internet has focused on edge devices, and there is a lack of deeper related studies of the energy wasted by excessive network-connectivity and the savings potential in wired network equipment. This study presents the background and reasonability of studies on the energy efficiency of wired networks in terms of the environment, economy and energy resources. The energy consumption and savings potential of network equipment were also estimated and the major factors of energy consumption was analyzed based on the data, and future studies for the Internet are presented.

A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy (Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구)

  • Hwang, Yong Ha
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF

Determination of Tool Orientation in 5-Axis Milling Using Potential Energy Method (포텐셜 에너지를 이용한 5축 NC 밀링의 공구방향 결정)

  • Cho, Inhaeng;Lee, Kunwoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.161-167
    • /
    • 1996
  • In five-axis milling, optimal CL-data (cutter location data) should be generated to have advantages over three-axis milling in terms of accuracy and efficiency. This paper presents an algorithm for generating collision-free CL-data for five-axis milling using potential energy method. By virtually charging the cutter and part surfaces with static electricity, global collision as wells as local interference is eliminated. Additionally, machining efficiency is improved by minimizing the curvature difference between the part surface and tool swept surface at a CC-point (cutter contact point) simultaneously.

  • PDF

Preliminary hydrodynamic assessments of a new hybrid wind wave energy conversion concept

  • Allan C de Oliveira
    • Ocean Systems Engineering
    • /
    • v.13 no.1
    • /
    • pp.21-41
    • /
    • 2023
  • Decarbonization and energy transition can be considered as a main concern even for the oil industry. One of the initiatives to reduce emissions under studies considers the use of renewable energy as a complimentary supply of electric energy of the production platforms. Wind energy has a higher TRL (Technology Readiness Level) than other types of energy converters and has been considered in these studies. However, other types of renewable energy have potential to be used and hybrid concepts considering wind platforms can help to push the technological development of other types of energy converters and improve their efficiency. In this article, a preliminary hydrodynamic assessment of a new concept of hybrid wind and wave energy conversion platform was performed, in order to evaluate the potential of wave power extraction. A multiple OWCs (Oscillating Water Column) WEC (Wave Energy Converter) design was adopted for the analysis and some simplifications were adopted to permit using a frequency domain approach to evaluate the mean wave power estimation for the location. Other strategies were used in the OWC design to create resonance in the sea energy range to try to maximize the potential power to be extracted, with good results.