• 제목/요약/키워드: Energy efficiency performance

검색결과 3,516건 처리시간 0.032초

The Energy Efficiency of Improved Routing Technique Based on The LEACH

  • Gauta, Ganesh;Cho, Seongsoo;Jung, Kyedong;Lee, Jong-Yong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권1호
    • /
    • pp.49-56
    • /
    • 2015
  • As WSN is energy constraint so energy efficiency of nodes is important. Because avoiding long distance communication, clustering operating in rounds is an efficient algorithm for prolonging the lifetime of WSN and its performance depends on duration of a round. A short round time leads to frequent re-clustering while a long round time increases energy consume of cluster heads more. So existing clustering schemes determine proper round time, based on the parameters of initial WSN. But it is not appropriate to apply the round time according to initial value throughout the whole network time because WSN is very dynamic networks nodes can be added or vanished. In this paper we propose a new algorithm which calculates the round time relying on the alive node number to adapt the dynamic WSN. Simulation results validate the proposed algorithm has better performance in terms of energy consumption of nodes and loss rate of data.

다이나믹 MPPT를 적용한 최대전력지점추종 알고리즘 (The New MPPT Algorithm for the Dynamic MPPT Efficiency)

  • 고석환;정영석;소정훈;황혜미;주영철
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.1-10
    • /
    • 2014
  • The efficiency of the maximum power point tracking(MPPT) of inverter which is used in grid-connected photovoltaic systems is changed according to dynamic environment conditions. Hence, this paper evaluates the performance of the proposed method and other MPPT algorithm on the basis of European Efficiency Test(EN50530). The modeling of MPPT algorithm is made by the Matlab & Simulink. In the result of simulation, the more control period is shorter, the more MPPT efficiency is higher. Also, the Proposed MPPT algorithm has higher performance than other MPPT algorithm with no regard to control period.

터빈 추기를 이용한 재생 유기랭킨사이클의 열역학적 성능 해석 (Thermodynamic Performance Analysis of Regenerative Organic Rankine Cycle using Turbine Bleeding)

  • 김경훈;황선;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.377-385
    • /
    • 2015
  • This paper presents a thermodynamic performance analysis of regenerative organic Rankine cycle (ORC) using turbine bleeding to utilize low-grade finite thermal energy. Refrigerant R245fa was selected as the working fluid. Special attention is paid to the effects of the turbine bleeding pressure and the turbine bleed fraction on the thermodynamic performance of the system such as net power production and thermal efficiency. Results show that the thermal efficiency has an optimum value with respect to the turbine bleeding pressure and the net power production is lower than the basic ORC while the thermal efficiency is higher.

로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구 (A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing)

  • 이나은;안병립;장철용;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

Performance Analysis of Energy-Efficient Secure Transmission for Wireless Powered Cooperative Networks with Imperfect CSI

  • Yajun Zhang;Jun Wu;Bing Wang;Hongkai Wang;Xiaohui Shang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권9호
    • /
    • pp.2399-2418
    • /
    • 2023
  • The paper focuses on investigating secure transmission in wireless powered communication networks (WPCN) that involve multiple energy-constrained relays and one energy-constrained source. The energy is harvested from a power beacon (PB) while operating in the presence of a passive eavesdropper. The study primarily aims to achieve energy-efficient secure communications by examining the impact of channel estimation on the secrecy performance of WPCN under both perfect and imperfect CSI scenarios. To obtain practical insights on improving security and energy efficiency, we propose closed-form expressions for secrecy outage probability (SOP) under the linear energy harvesting (LEH) model of WPCN. Furthermore, we suggest a search method to optimize the secure energy efficiency (SEE) with limited power from PB. The research emphasizes the significance of channel estimation in maintaining the desired performance levels in WPCN in real-world applications. The theoretical results are validated through simulations to ensure their accuracy and reliability.

An experimental performance analysis of a cold region stationary photovoltaic system

  • Choi, Wongyu;Warren, Ryan D.;Pate, Michael B.
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.1-28
    • /
    • 2016
  • A grid-connected photovoltaic (PV) system comprised of multicrystalline silicon (mc-Si) modules was installed in a cold climate region in the U.S. This roof-mounted stationary PV system is a real-world application of PV for building energy generation in International Energy Conservation Code (IECC) Climate Zone 5 (and possibly similar climate zones such as 6, 7 and 8), and it served the purposes of research, demonstration, and education. The importance of this work is highlighted by the fact that there has been less emphasis on solar PV system in this region of the U.S. because of climate and latitude challenges. The system is equipped with an extensive data acquisition system capable of collecting performance and meteorological data while visually displaying real-time and historical data through an interactive online interface. Experimental data was collected and analyzed for the system over a one-year period with the focus of the study being on measurements of power production, energy generation, and efficiency. The annual average daily solar insolation incident upon the array was found to be $4.37kWh/m^2$. During the first year of operation, the PV system provided 5,801 kWh (1,264 kWh/kWp) of usable AC electrical energy, and it was found to operate at an annual average conversion efficiency and PR of 10.6 percent and 0.79, respectively. The annual average DC to AC conversion efficiency of the inverter was found to be 94 percent.

현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가 (Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test)

  • 이효문;윤종호;김현일;이건환
    • 한국태양에너지학회 논문집
    • /
    • 제40권5호
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.

열전모듈 냉장고의 에너지 효율에 미치는 설계인자의 영향 (The Effect of Design Parameters on the Energy Efficiency of a TEM Refrigerator)

  • 이태희;김진호
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권3호
    • /
    • pp.29-34
    • /
    • 2018
  • To present the design direction of the thermoelectric module (TEM) refrigerator, analysis of the effect of the design parameters on the energy efficiency and performance of the refrigerator is performed. The design parameters considered are the cooling capacity of the TEM and the heat transfer performance of the heating and cooling surface of the TEM. The heat transfer performance is the most effective design parameter for improving cooling power. The smaller ΔT and cooling capacity of the TEM make the higher efficiency of the refrigerator.

A minimum energy control of a load-sensing hydraulic servo system

  • Kim, S.D.;Cho, H.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.747-752
    • /
    • 1987
  • The dynamic characteristics of a load-sensing hydraulic servo system are complex and highly unstable. Another property of the system is that the setting value of pump compensator is closely related to energy efficiency as well as control performance of the system. This necessitates the development of an effective control algorithm which guarantees good control performance, stability and energy efficiency. This paper considers a suboptimal PID control for the velocity control problem of the load-sensing hydraulic servo system. The results of simulations studies and experiments show that the proposed suboptimal controller can produce much better control performance than nonoptimal controllers and give effective energy efficiency.

  • PDF

Sensitive analysis of design factor for the optimum design of PVT system

  • Jeong, Yong-Dae;Nam, Yujin
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2015
  • Purpose: Recently, renewable energy system has been widely used to reduce the energy consumption and CO2 emission of building. A photovoltaic/thermal(PVT) system is a kind of efficient energy uses, which is combined with photovoltaic module and solar thermal collector. PVT system removes heat from PV module by through thermal fluid to raise the performance efficiency of the PV system. However, though PVT system has the merit of the improved efficiency in theoretical approach, there have been few performance analysis for PVT system using the dynamic energy simulation. In this study, in order to establish the optimum design method of this system, simulation was conducted by using individual system modules. Method: For the dynamic simulation, TRNSYS17 was used and local weather data was utilized. Furthermore, the system performance in various installation condition was calculated by case studies. Result: As a result, the amount of electric generation and heat production in each case was found by the simulation. The gap of system performance was also evident according to the installation condition.