• 제목/요약/키워드: Energy efficiency evaluation

검색결과 867건 처리시간 0.03초

확산필름 부착 위치에 따른 광선반 성능개선 연구 (Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position)

  • 박은수;이행우;송석재;김용성
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.

5kW 급 주택용 고분자 연료전지 시스템 (Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation)

  • 양태현;박구곤;윤영기;이원용;윤왕래;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

p-type HPGe 검출기 특성에 따른 밀도 보정인자 의존도 평가 (Dependence Evaluation of the Self-Absorption Correction Factor for p-type High Purity Germanium Detector Characteristics)

  • 장미;지영용;김창종;이완로;강문자
    • 방사성폐기물학회지
    • /
    • 제13권4호
    • /
    • pp.295-300
    • /
    • 2015
  • HPGe 검출기를 이용하여 밀도가 다양한 환경시료에 대한 정밀 분석시 정확한 분석을 위해서는 밀도보정인자가 필요하다. 밀도에 대한 보정인자를 구하기 위해서 본 연구에서는 몬테카를로 코드인 MCNPX 코드를 사용하여 크리스털의 높이, 지름 및 코어의 크기와 같은 특성이 다른 세 대의 p-type HPGe 검출기를 모사하고 밀도 $1g/m^3$의 교정용 표준시료를 이용하여 모델링을 검증하였다. 검증을 통하여 모델링을 확정한 후 0.3, 0.6, 0.9, 1.0, 1.2, $1.5g/m^3$ 밀도를 가진 샘플에 대한 효율을 시뮬레이션하고 밀도보정인자를 도출하였다. 도출된 각 검출기에 대한 밀도보정인자를 비교하였을 때 전 에너지 범위에서 그 차이가 거의 없음을 확인하였으며 이는 검출기의 크리스털과 같은 주요 특성에 대해 밀도보정인자가 독립적임을 의미한다.

Efficiency Index Diagram for Wake Region Evaluation of Artificial Reefs Facilitated for Marine Forest Creation

  • Kim, Dongha;Jung, Somi;Na, Won-Bae
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제2권4호
    • /
    • pp.169-178
    • /
    • 2016
  • Recently, artificial reefs (ARs) have been frequently used primarily owing to the development in AR materials and projects for relatively complicated, large ARs. Among several engineering issues of ARs, wake region of an AR has been characterized because these regions have a high probability of recruiting seaweed spores, providing an energy saving zone, and facilitating deposition of sediments, nutrients, and bio-deposits. To characterize an efficiency index of an AR wake region and its dependency on the prevailing water flow directions, this study proposes a so-called efficiency index diagram. This characterization is done by normalizing the wake volumes with respect to the real AR volume and illustrating how efficiency indices vary with respect to the inlet flow directions. As a result, according to the diagram characteristics such as an averaged efficiency index, fundamental symmetric angle, secure angles, and principal directions, we can easily figure out how a target AR should be aligned along the main water flows to maximize the wake region around the AR. In addition, six ARs are considered and their efficiency index diagrams are illustrated to pinpoint the physical characteristics.

EnergyPlus 해석용 수랭식 VRF 히트펌프의 냉·난방 능력 및 소비전력 예측식 산출 기법 (Capacity and Power Input Performance Curves Creation of Water-cooled VRF Heat Pump for EnergyPlus)

  • 김민지;권혁주;이광호
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권3호
    • /
    • pp.1-8
    • /
    • 2017
  • Variable refrigerant flow (VRF) systems have recently attracted attention in many countries due to a variety of advantages over conventional system. Especially, the water-cooled VRF heat pump, including geothermal heat pump, is a system that accurately controls the flow rate of refrigerant for the improved efficiency under part load operation. This paper describe the process of generating the cooling and heating energy performance curve coefficients and performance expressions for modeling water cooled VRF system using EnergyPlus. Through this study, the process for generating performance curves can be implemented into EnergyPlus or other comparable building energy analysis tools for the long-term evaluation of heat pump under dynamic conditions.

지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가 (Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System)

  • 박시삼;나상민;박종헌;이건중;김태원;김승엽
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

공동주택 변압기용량 적정 산정을 위한 수용률 개선 및 사례 연구를 통한 경제성 평가 (The Study on Estimation of The Transformer Capacity of Housing and Economic Evaluation Using Case Studies)

  • 이윤상;서정열;신희상;조성민;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.142-149
    • /
    • 2010
  • Interest in energy efficiency and savings have been rising internationally. For this reason, the domestic housing construction in the area of power equipment is being actively studied. Currently approximately 400,000 per year of domestic housing is being built. Applies to housing construction during the current transformer capacity low utilization and load factor has been applied has been designed. In other words, excessively high reserve capacity has been applied. According to this problem, initial facility costs and power losses will cause because transformer low utilization be appropriated. Thus, the energy efficiency drops. In this paper, analysis of past utilization of the housing transformer, and applying an appropriate demand factor has been analyzing the energy loss reduction. this analysis of current domestic conditions for the proper housing transformer scheme is to calculate the capacity.

KS C 8562 평가를 통한 CIGS 태양광모듈의 출력 거동 분석 (Current-Voltage Measurement Behavior of the CIGS Solar Module through the Evaluation of KS C 8562 Standard)

  • 김경수
    • Current Photovoltaic Research
    • /
    • 제12권2호
    • /
    • pp.41-47
    • /
    • 2024
  • CIGS solar cells are thin film solar cells that have excellent light absorption coefficient and can be manufactured with high efficiency through the use of low materials. In Korea, they must pass KS certification for home and commercial installation. KS C 8562 is a standard for evaluating the durability of CIGS and thin film amorphous silicon solar modules and deals with contents such as light, temperature, humidity, and mechanical durability. Unlike general crystalline silicon solar modules, the CIGS solar module has a different behavior of output change through these environmental tests, so if it shows 90% or more of the rated output suggested by the manufacturer after the final test, it is judged to be a suitable product. In this paper, the output before and after individual tests was measured through the test method of KS C 8562 to observe the output change and to discover the vulnerabilities of the CIGS solar module when exposed to various environments. Through this, it was confirmed that humidity exposure was the most vulnerable and that it had output recovery characteristics for light (visible light and ultraviolet rays). This study attempted to present the output behavior characteristics and data of the CIGS module at the time when the high efficiency thin film photovoltaic module market is expected to be created in the future.

DEA 모형을 활용한 국내 발전회사의 효율성 평가 (An Efficiency Evaluation of Korea's Electric Power Generation Industries using DEA model)

  • 고승철;심광식;김재윤
    • 한국국방경영분석학회지
    • /
    • 제34권1호
    • /
    • pp.61-77
    • /
    • 2008
  • 본 연구에서는 의사결정기관의 상대적 효율성을 측정할 수 있는 유용한 기법으로 알려진 DEA 모형을 이용하여 국내 6개 발전회사의 효율성을 비교 분석하였다. 투입방향 CCR 및 BCC 모형에 의해서 분석된 연구 결과로는 첫째, 총 발전설비용량을 투입변수로 사용하였을 때와 각 발전원별로 설비용량을 구분하여 투입변수로 사용하였을 때와 서로 다른 연구결과를 얻었다. 이는 각 발전설비의 고정비(발전설비)와 변동비(연료비) 특성이 감안된 결과로 생각된다. 둘째, 본 연구에서 논의된 발전원별 투입변수가 중장기 발전설비용량 확장계획 기간의 효율성 평가에 사용되면 각 발전회사의 효율성은 현재 수준보다 높아질 것이다. 본 연구는 발전회사의 효과적인 경영활동을 위한 유익한 정보를 제공할 수 있을 것으로 기대된다.

IEEE 802.15.6 UWB WBAN에서 다중 홉 전송에 대한 성능 평가 (Performance Evaluation of Multi-Hop Transmissions in IEEE 802.15.6 UWB WBAN)

  • 김호성;황호영
    • 한국정보통신학회논문지
    • /
    • 제21권7호
    • /
    • pp.1313-1319
    • /
    • 2017
  • 본 논문에서는 IEEE 802.15.6 초광대역(Ultra Wide Band, UWB) 무선 인체 영역 네트워크(Wireless Body Area Networks, WBAN)에서 다중 홉 전송에 대한 성능을 평가한다. IEEE 802.15.6 UWB WBAN에 대한 물리 계층 패킷 구조와 인코딩, 디코딩 과정을 고려한다. 데이터 페이로드의 길이, 전송 전력 세기, 노드들간 거리에 따라 한 홉 전송, 두 홉 전송, 세 홉 전송에 대한 데이터 전송 성공률과 에너지 효율을 제안하고 분석한다. 시뮬레이션을 통해, 한 홉 전송, 두 홉 전송, 세 홉 전송에서 데이터 페이로드의 길이, 전송 전력 세기, 노드들간 거리의 변화에 따라 달라지는 데이터 전송 성공률과 에너지 효율에 대해 비교하고 평가한다. 최종적으로 다양한 변수와 상황에 따라 다중 홉 전송에 대한 에너지 효율을 파악하고, 에너지 효율이 가장 높은 전송 방법을 택하여 전송할 수 있음을 보인다.