• 제목/요약/키워드: Energy efficiency evaluation

검색결과 868건 처리시간 0.03초

열풍과 원적외선 겸용 연속식 백삼 건조기의 개발 (Development of a Prototype Continuous Flow Dryer using For Infrared Ray and Heated -air for White Ginseng)

  • 박승제;김성민;김명호;김철수;이종호
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.115-122
    • /
    • 2000
  • This study was performed to develop a prototype continuous flow ginseng dryer with which better product quality and lower drying energy consumption could be achieved compared with conventional ginseng dryers. A dryer having both far infrared ray (IR) and heated-air as the drying energy sources was designed and fabricated . Dryer performance was studied by examining energy efficiencies and dryer performance evaluation indices (DPEI) during the drying tests of medium-sized four year ginseng roots with IR radiating plate temperature and drying air temperature in the range of 80-12$0^{\circ}C$ and 22-5$0^{\circ}C$, respectively. The DPEI of IR /heated -air combined drying was 1/3 of that of the conventional heated-air drying when ginseng were dried to the same final moisture ratio. When ginsengs were dried for 12 hours in the prototype IR/heated-air combination dryer, a linear relationship was found to exist between final moisture ratio and ginseng temperature. As the drying progressed, drying air temperature inside the dryer was nearly constant but ginseng temperature was drastically increased during the first two hours and gradually increased thereafter until the end of drying. With the prototype Ir/heated-air combination dryer, the drying rate changed little but the energy efficiency increased proportionally when the amount of ginseng to be dried increased. Drying capacity, energy efficiency, and DPEI of the prototype IR/heated-air combination ginseng dryer were estimated to 1.500 roots, 65% and 3.800kJ/kg-water , respectively.

  • PDF

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

무선 채널의 에너지 소비를 줄이기 위한 공평 큐잉 알고리즘 (A Fair Queuing Algorithm to Reduce Energy Consumption in Wireless Channels)

  • 김태준
    • 한국멀티미디어학회논문지
    • /
    • 제10권7호
    • /
    • pp.893-901
    • /
    • 2007
  • 품질 보장을 요구하는 실시간 멀티미디어 서비스가 이동 무선 네트워크로 확산됨에 따라 무선 채널에서 에너지 효율의 중요성이 더욱 강조되고 있으며, DMS(Dynamic Modulation Scaling)의 도입으로 스케줄러의 출력 링크의 속도를 낮춤으로서 무선 채널의 에너지 소비를 줄일 수 있게 되었다. 본 연구에서는 WFQ(Weighted Fair Queuing)의 대역폭 이용도 저하 문제를 해결한 LOFQ(Latency-Optimized Fair Queuing)를 확장하여 출력 링크의 속도를 줄일 수 있는 공평 큐잉 알고리즘인 REFQ(Rate Efficient Fair Queuing)를 제안하고 성능을 평가한다. 평가결과 WFQ에 비해서 35%의 링크 속도 절감 효과를 얻었고, DMS 무선 모뎀에 적용 시 에너지 소비를 최대 90% 정도 줄일 수 있었다.

  • PDF

에너지 흡수효율에 의한 구조물간 내진 성능 비교 (Comparative Seismic Evaluation of Structures by Energy Absorption Efficiency)

  • 김장훈
    • 한국지진공학회논문집
    • /
    • 제5권3호
    • /
    • pp.37-43
    • /
    • 2001
  • 다양한 구조시스템간 반복하중에 대한 거동 성능을 비교하고자 에너지 개념을 확장하였다. 이로부터 에너지 흡수효율이 정의되었는데 이는 구조체의 누적에너지 흡수능력을 기준이 되는 탄성-완전소성시스템의 누적에너지 흠수량으로 나누어 무차원화한 것이다. 이를 위하여 반복하중실험으로부터 구한 실험결과들을 정리하여 에너지곡선의 형태로 표현하여야 한다. 제안된 방법을 이용하여 기하학적으로, 재료적으로 또한 구법이 서로 상이한 구조체간의 내진 성능에 대한 상대적이며 객관적인 비교가 가능해진다. 또한 이 방법의 가장 큰 장점 중의 하나는 구조물의 파괴형태와 관계없이 반복하중에 의한 힘-변위 관계만 주어지면 충분하다는 것이다. 제안된 방법을 두 시험체의 실험결과에 적용하여 그 타당성을 입증하여 보았다.

  • PDF

Recognition of Occupants' Cold Discomfort-Related Actions for Energy-Efficient Buildings

  • Song, Kwonsik;Kang, Kyubyung;Min, Byung-Cheol
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.426-432
    • /
    • 2022
  • HVAC systems play a critical role in reducing energy consumption in buildings. Integrating occupants' thermal comfort evaluation into HVAC control strategies is believed to reduce building energy consumption while minimizing their thermal discomfort. Advanced technologies, such as visual sensors and deep learning, enable the recognition of occupants' discomfort-related actions, thus making it possible to estimate their thermal discomfort. Unfortunately, it remains unclear how accurate a deep learning-based classifier is to recognize occupants' discomfort-related actions in a working environment. Therefore, this research evaluates the classification performance of occupants' discomfort-related actions while sitting at a computer desk. To achieve this objective, this study collected RGB video data on nine college students' cold discomfort-related actions and then trained a deep learning-based classifier using the collected data. The classification results are threefold. First, the trained classifier has an average accuracy of 93.9% for classifying six cold discomfort-related actions. Second, each discomfort-related action is recognized with more than 85% accuracy. Third, classification errors are mostly observed among similar discomfort-related actions. These results indicate that using human action data will enable facility managers to estimate occupants' thermal discomfort and, in turn, adjust the operational settings of HVAC systems to improve the energy efficiency of buildings in conjunction with their thermal comfort levels.

  • PDF

Evaluation of the MgO Protective Layer Deposited by Oxygen Ion-Beam-Assisted-Deposition Method in ac PDPs

  • Li, Zhao-Hui;Cho, Eou-Sik;Hong, Seong-Jae;Kwon, Sang-Jik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1372-1375
    • /
    • 2007
  • MgO thin films were deposited by $O^+$ IBAD method and results showed assisting oxygen ion beam energy plays a significant role in characteristics of MgO thin films. The lowest firing inception voltage, the highest brightness and the highest luminous efficiency were obtained when oxygen ion beam energy was 300 eV.

  • PDF

풍력-기상자원지도에 기반한 제주 행원 풍력발전단지 효율성 평가 (Evaluation of Wind Turbine Efficiency of Haengwon Wind Farm in Jeju Island based on Korean Wind Map)

  • 변재영;강미선;정현숙
    • 한국지구과학회지
    • /
    • 제34권7호
    • /
    • pp.633-644
    • /
    • 2013
  • 풍력 발전단지의 효율성 평가를 위하여 풍력-기상자원지도로부터 이론적 잠재량을 계산하고 행원 발전단지 발전량과 비교하였다. 풍력-기상자원지도는 기상청 국립기상연구소에서 개발된 1 km 해상도 자료를 이용하였다. 풍력-기상자원지도와 AWS(구좌) 풍속의 비교 검증 결과는 풍속이 과대 모의되었으며, 행원 발전단지 풍속의 일 변동성은 해륙풍의 영향으로 오후에 최대가 되는 일 변동 특성을 보였다. 풍력-기상자원지도로부터 산출된 발전량과 행원 발전단지 발전량의 비율은 24.8%이나, 발전량 빈도수 분포 형태는 유사하였다. 발전량 차이의 원인은 터빈의 기계적 오류, 풍력-기상자원지도 풍속의 과대 모의에 기인한 것으로 생각된다. 본 연구는 향후의 발전단지 효율성 증가를 위한 터빈의 재배치에 기여 할 것이다.

치어기 황복(Takifugu obscurus) 사료 내 에너지에 대한 적정 단백질 비 평가 (Evaluation of the Optimum Dietary Protein to Energy Ratio in Juvenile River Puffer Takifugu obscurus)

  • 유광열;배승철
    • 수산해양교육연구
    • /
    • 제26권4호
    • /
    • pp.868-876
    • /
    • 2014
  • This study was conducted to estimate the optimum dietary protein to energy (P/E) ratio in juvenile river puffer. Nine experimental diets were formulated with three energy levels and three protein levels at each energy levels. Three energy levels of 3000, 3750 and 4500 kcal diets were included at 45, 50 and 55% crude protein (CP) levels, respectively (45P3000, 45P3750, 45P4500, 50P3000, 50P3750, 50P4500, 55P3000, 55P3750 and 55P4500). Fish averaging $3.43{\pm}0.02$ g randomly were fed the experimental diets in triplicate groups for 8 weeks. Weight gain of fish fed the 50P4500 diet were significantly higher than that of fish fed the 45P3000, 45P3750, 45P4500, 50P3000 and 50P3750 diets (P<0.05), but there was not significantly different from that of fish fed the 50P4500, 55P3750 and 55P4500 diets. Feed efficiency of fish fed the 50P4500 diet were significantly higher than that of fish fed the 45P3000, 45P3750, 45P4500, 50P3000 and 50P3750 diets (P<0.05), but there was not significantly different from that of fish fed the 50P4500, 55P3000, 55P3750 and 55P4500 diets. Protein efficiency ratio of fish fed the 45P3000 and 45P3750 diets was higher than that of fish fed 50P4500 and 55P4500, but there was not significantly different from that of fish fed the 45P3000, 45P3750, 45P4500, 50P3000, 50P3750, 55P3000 and 55P3750 diets. Based on weight gain, feed efficiency and specific growth rate, diets containing energy levels 4500 kcal/kg diet had an optimum P/E ratio of approximately 111 mg protein/kcal (50% crude protein) in juvenile river puffer.

공공하수처리장의 에너지 소비현황 및 효율성 평가 (Energy Efficiency Evaluation of Publicly Owned Wastewater Utilities)

  • 조을생;한대호;하종식
    • 환경정책연구
    • /
    • 제11권4호
    • /
    • pp.85-105
    • /
    • 2012
  • 국내 공공하수처리시설의 운영적 측면의 에너지 절감을 위한 방안을 모색하기 위해 에너지 효율성을 평가하였다. 하수처리시설의 에너지 사용에 영향을 미치는 변수를 통계적(유의수준 5%)으로 분석한 결과 유입하수량, 유입 COD, 유입 BOD, 고도처리비율, 유입 TN, 유입 TP, 실제 처리용량/설계용량 비율(가동률)로 나타나 국내 하수처리시설의 에너지 사용은 주로 하수 유입수의 성상 및 하수처리시설 가동률에 영향을 받는 것으로 분석되었다. 또한 회귀분석결과, 에너지 효율성이 평균(50 백분위수) 이상인 하수처리장 비율을 공법별로 살펴보면, A2O 공법을 적용하고 있는 하수처리시설이 상대적으로 에너지 효율성이 높게 운영된 것으로 평가되었으며 반면에 고도처리 공법에서는 분리막 고도처리, 2차 처리공법에서는 접촉산화법을 적용하고 있는 하수처리시설의 에너지 효율성 개선 노력이 상대적으로 더 많이 요구되는 것으로 나타났다. 그러나 보다 정확한 하수처리시설의 에너지 소비산정 및 분석을 위해서는 처리시설의 에너지 사용 모니터링 시스템 구축 및 에너지 소비시설의 정확한 DB 구축이 시급한 실정이다. 특히, 기존 하수도 통계자료에 i) 중계펌프 사용 전력량, ii) 단위공정별 전력량, iii) 처리수 장거리 방류시 펌프 전력사용량, iv) 대체에너지 생산량 및 활용현황 등에 대한 정확한 자료가 보완되어야 한다. 기초자료가 제대로 구축될 경우 유사한 하수처리시설의 에너지 소비 형태에 대해 구체적으로 비교 분석이 가능하며 분석결과를 활용하여 벤치마킹을 통한 각 하수처리장들의 특성에 따른 맞춤형 에너지 절감 방안이 수립될 수 있을 것이다.

  • PDF

Conformational Dependent Energy Migration on Cyclic Porphyrin Arrays

  • Song, Suwhan;Han, Minwoo;Sim, Eunji
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.163-166
    • /
    • 2015
  • Intramolecular energy migration in a cyclic porphyrin array is spontaneous transfer of energy from one excited site to another. Since the efficiency of energy migration is inversely proportional to distance, the energy migration is occurred on their adjacent sites more often than distant ones. Therefore, the energy migration in the cyclic porphyrin array is largely dependent on their conformational characters. However, evaluation of conformational information by means of experimental tools is ambiguous since their limited resolution. In this work, we calculate the internal angle and distance distributions of cyclic porphyrin arrays using molecular dynamics simulations to obtain conformational information. To evaluate the angle and distance distributions respect to molecular size, we constructed molecules with n porphyrin dimers (n=1,3,7) in implicit solvent environment. Performing molecular dynamics simulations, we modulated alkyl groups to investigate additional conformational effects of the system.

  • PDF