• Title/Summary/Keyword: Energy calibration

Search Result 434, Processing Time 0.027 seconds

A Case Study on the Application of Systems Engineering to the Development of PHWR Core Management Support System (시스템엔지니어링 기법을 적용한 가압중수로 노심관리 지원시스템 개발 사례)

  • Yeom, Choong Sub;Kim, Jin Il;Song, Young Man
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.9 no.1
    • /
    • pp.33-45
    • /
    • 2013
  • Systems Engineering Approach was applied to the development of operator-support core management system based on the on-site operation experience and document of core management procedures, which is for enhancing operability and safety in PHWR (Pressurized Heavy Water Reactor) operation. The dissertation and definition of the system were given on th basis of investigating and analyzing the core management procedures. Fuel management, detector calibration, safety management, core power distribution monitoring, and integrated data management were defined as main user's requirements. From the requirements, 11 upper functional requirements were extracted by considering the on-site operation experience and investigating documents of core management procedures. Detailed requirements of the system which were produced by analyzing the upper functional requirements were identified by interviewing members who have responsibility of the core management procedures, which were written in SRS (Software Requirement Specification) document by using IEEE 830 template. The system was designed on the basis of the SRS and analysis in terms of nuclear engineering, and then tested by simulation using on-site data as a example. A model of core power monitoring related to the core management was suggested and a standard process for the core management was also suggested. And extraction, analysis, and documentation of the requirements were suggested as a case in terms of systems engineering.

Green Synthesis of Platinum Nanoparticles by Electroreduction of a K2PtCl6 Solid-State Precursor and Its Electrocatalytic Effects on H2O2 Reduction

  • Kim, Kyung Tae;Jin, Sung-Ho;Chang, Seung-Cheol;Park, Deog-Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3835-3839
    • /
    • 2013
  • A new synthesis route for Pt nanoparticles by direct electrochemical reduction of a solid-state Pt ion precursor ($K_2PtCl_6$) is demonstrated. Solid $K_2PtCl_6$-supported polyethyleneimine (PEI) coatings on the surface of glassy carbon electrode were prepared by simple mixing of solid $K_2PtCl_6$ into a 1.0% PEI solution. The potential cycling or a constant potential in a PBS (pH 7.4) medium were applied to reduce the solid $K_2PtCl_6$ precursor. The reduction of Pt(IV) began at around -0.2 V and the reduction potential was ca. -0.4 V. A steady state current was achieved after 10 potential cycling scans, indicating that continuous formation of Pt nanoparticles by electrochemical reduction occurred for up to 10 cycles. After applying the reduction potential of -0.6 V for 300 s, Pt nanoparticles with diameters ranging from $0.02-0.5{\mu}m$ were observed, with an even distribution over the entire glassy carbon electrode surface. Characteristics of the Pt nanoparticles, including their performance in electrochemical reduction of $H_2O_2$ are examined. A distinct reduction peak observed at about -0.20 V was due to the electrocatalytic reduction of $H_2O_2$ by Pt nanoparticles. From the calibration plot, the linear range for $H_2O_2$ detection was 0.1-2.0 mM and the detection limit for $H_2O_2$ was found to be 0.05 mM.

MASK: Multi-frequency AGN Survey with the KVN

  • Jung, Taehyun;Zhao, Guangyao;Kim, Minsun;Sohn, Bong Won;Byun, Do-Young;Wagner, Jan;Wajima, Kiyoaki;Cea, Christian Saez de;Kwon, Woojin;Lee, Jeong Ae;Cho, Ilje;Jeong, Dawoon;Kim, Dongjin;Ryu, Dongsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.32.3-32.3
    • /
    • 2016
  • Available VLBI sources at high frequencies (e.g. >22GHz) are very limited - mainly due to atmospheric fluctuations that degrade coherence time and a power-law energy distribution of particles in case of AGNs. However, simultaneous multi-frequency VLBI receiving system of the Korean VLBI Network (KVN) and its powerful VLBI phase calibration technique offer benefits in finding more weak sources at millimeter wavelengths. Based on this aspect, multi-frequency AGN survey with the KVN (MASK) project, which aims to densify an existing a VLBI catalog of extragalactic radio sources at 22/43/86/129GHz is proposed as a KVN legacy program. We selected 1220 sources of AGNs that include known VLBI sources and new fringe-detected sources using the KVN at K-band (22GHz). Among them, 138 sources were observed as pilot experiments at 22/43/86/129GHz simultaneously and excellent VLBI detection results are achieved. Therefore, we expect that MASK will open a new era in VLBI science at millimeter wavelengths by providing unprecedented number of available sources in the Universe.

  • PDF

Characterization of A Catalystic Gas Sensor for Measuring Heat Content of Natural Gas (천연가스의 열용량을 측정하기 위한 촉매가스센서의 특징)

  • Lee K. Y.;Maclay G. J.;Stetter J. R.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • A low power (below than 300 mW) catalytic bead combusible gas sensor is developed and utilized with a computer controlled sampling system for measuring heat content of natural gas. The heat content of gas is proportional to the change in the energy required to exposure to the sample of combustible gas. The heat content of natural gas samples ranging 36.30 - 39.88 $MJ/m^3$ is measured in the range of approximately $1\%$ error, which is comparable to its nominal heat content. Each gas represents a slightly different curve of sensitivity to sensor temperature. Thus all of the sensitivities are not equal to every temperature. In calibration process the choice of a optimum operating temperature is an important factor that influences the overall performance of the measurement system.

  • PDF

A Fabrication and Properties of Ionization Chamber Using Madium Exposure Rate (중준위 조사선량율 측정용 전리함의 설계 및 특성)

  • Woo, Hong;Kim, Sung-Hwan;Kang, Hee-Dong
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.29-40
    • /
    • 1996
  • We had designed and made the cylindrical ionization chamber which operated above 5 mR/h. Using commercial electrometer, we investigated the characterictic of charge collection in the ion chamber. The active volume was 190.4㎤ and overall length and diameter in the chamber was 15.5cm, 5.22cm, respectively. The chamber had three electrodes(inner, central, wall electrode). And background current was 8.39${\times}$10$\^$-14/${\pm}$1.5${\times}$10$\^$-15/A to arrange the electrodes which were coaxial in chamber axis. The collection efficiency of chamber for Cs$\^$137/ was 99.7% when the opreating voltage was applied 400V. Comparing with the commertial dosimetry system, the exposure calibration constant was 4.531${\times}$19$\^$7/R/C. By normalizing to CS$\_$137/ the relative energy response of the chamber was 1.30 for Am$\_$24/, 1.05 for C0$\_$60/, respectively. When the irrarition tranversed to the chamber axis, the isotropic effect of the chamber was not considerable.

  • PDF

Properties of Water Substitute Solid Phantoms for Electron Dosimetry

  • Saitoh, Hidetoshi;Tomaru, Teizo;Fujisaki, Tatsuya;Abe, Shinji;Myojoyama, Atsushi;Fukuda, Kenichi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.255-259
    • /
    • 2002
  • To reduce the uncertainty in the calibration of radiation beams, absorbed dose to water for high energy electrons is recommended as the standards and reference absorbed dose by AAPM Report no.51 and IAEA Technical Reports no.398. In these recommendations, water is, defined as the reference medium, however, the water substitute solid phantoms are discouraged. Nevertheless, when accurate chamber positioning in water is not possible, or when no waterproof chamber is available, their use is permitted at beam qualities R$\_$50/ < 4 g/cm$^2$ (E$\_$0/ < 10 MeV). For the electron dosimetry using solid phantom, a depth-scaling factor is used for the conversion of depth in solid phantoms to depth in water, and a fluence-scaling factor is used for the conversion of ionization chamber reading in plastic phantom to reading in water. In this work, the properties, especially depth-scaling factors c$\_$p1/ and fluence-scaling factors h$\_$pl/ of several commercially available water substitute solid phantoms were determined, and the electron dosimetry using these scaling method was evaluated. As a result, it is obviously that dose-distribution in solid phantom can be converted to appropriate dose-distribution in water by means of IAEA depth-scaling.

  • PDF

Method for the Measurement of Dissolved Oxygen in a Cell Culture Microchannel Using Oxygen-Sensitive Luminescence (산소 민감 발광 염료를 이용한 마이크로 채널 내에서 배양되는 세포 주변의 산소 농도 측정)

  • Lee, Seung-Youl;Jin, Song-Wan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.533-538
    • /
    • 2012
  • In this study, we used an $O_2$-sensitive luminescent dye to measure the $O_2$ concentration of culture media around HeLa cells cultured in a microchannel. $[Ru(bpy)_3]^{2+}$, which dissolves easily in water and which has no phototoxic effect, was used as the $O_2$-sensitive dye. The ratiometric sensing method was applied by introducing calcein as the $O_2$-insensitive dye, in order to overcome the disadvantages of intensity-based sensing. By performing calibration with an amperometric $O_2$ sensor, we could calculate the exact concentration of $O_2$ in the culture media. We applied this technique to measure the $O_2$ concentration around the cultured cells in the microchannel. As expected, the $O_2$ concentration gradually decreased as the cells moved farther away from the channel. This method is expected to be applicable to the investigation of hypoxia, which occurs commonly in scaffolds.

Cable-pulley brace to improve story drift distribution of MRFs with large openings

  • Zahrai, Seyed Mehdi;Mousavi, Seyed Amin
    • Steel and Composite Structures
    • /
    • v.21 no.4
    • /
    • pp.863-882
    • /
    • 2016
  • This study aims to introduce a new bracing system by which even super-wide frames with large openings can be braced. The proposed system, hereafter called Cable-Pulley Brace (CPB), is a tension-only bracing system with a rectilinear configuration. In CPB, a wire rope passes through a rectilinear path around the opening(s) and connects the lower corner of the frame to its opposite upper one. CPB is a secondary load resisting system with a nonlinear-elastic hysteretic behavior due to its initial pre-tension load. As a result, the required energy dissipation would be provided by the MRF itself, and the main intention of using CPB is to contribute to the initial and post-yield stiffness of the whole system. Using a stiffness calibration technique, optimum placement of the CPBs is discussed to yield a uniform displacement demand along the height of the structure. A displacement-based design procedure is proposed by which the MRF with CPB can be designed to achieve a uniform distribution of inter-story drifts with predefined values. Obtained results indicated that CPB leads to significant reductions in maximum and residual deformations of the MRF at the expense of minor increase in the maximum base shear and developed axial force demands in the columns. In the case of a typical 5-story residential building, compared to SMRF system, CPB system reduces maximum amounts of inter-story and residual drifts by 35% and 70%, respectively. Moreover, openings of the frame are not interrupted by the CPB. This is the most appealing feature of the proposed bracing system from architectural point of view.

Applicability Evaluation to Grid-based Rainfall-Runoff-Sediment Model for Sediment Discharge Estimation (격자기반 강우-유출-유사 모형의 유사량 산정에 관한 적용성 평가)

  • Choi, Hyun Gu;Park, Jun Hyung;Han, Kun Yeun
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.132-143
    • /
    • 2017
  • It is essential to obtain periodic sediment discharge data in a river in order to minimize problems that may arise from the erosion, transport, and deposition of sediment. However, it is difficult to estimate sediment discharge by the sediment discharge measurement plan in Korea at present, and empirical fomulas or numerical models are used to replace them. This paper has applied the K-DRUM model, a grid-based rainfall-runoff-sediment model, to estimate sediment discharge and ensure the continuity of the data in the watershed. Discharge and sediment load in 17 watersheds were estimated and the applicability of the model was analyzed through comparisons with measured data. For quantitative evaluation, NSE, PBIAS and RSR items were used, and discharge results reflected the tendency of rainfall and showed high statistical value. In case of sediment discharge, the soil erosion process of the watershed is physically well reflected. When the calibration was performed using the measure data, the applicability seems to be excellent in estimating the continuous sediment discharge data in the real watershed.

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.