• Title/Summary/Keyword: Energy basic unit

Search Result 155, Processing Time 0.026 seconds

Life Cycle Assessment for the Business Activities of Green Company -1. Analysis of Process Flow and Basic Unit (녹색기업의 사업활동 전 과정에 대한 환경성 평가 -1. 공정 흐름 및 원단위 분석)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.269-279
    • /
    • 2013
  • In this paper, an environmental assessment was carried out on the whole process of industrial business activities to establish a basic plan for climate change mitigation and energy independency. The whole process was divided into each discharge process in terms of water, air, solid waste, green house gases and refractory organic compounds. The flowcharts and basic unit of process were analysed for three years (2008-2010), being utilized as basic information for the life cycle assessment. It was found that the unit loading for the whole process significantly depends on changes in the operation rate change and highly concentrated wastewater inflow. About 35% of solid waste production was reduced by improving the incineration method with co-combustion in coal boiler, generating about 57% of electricity used for the whole process, and consequently reducing the energy costs. As the eco-efficiency index was found to be more than 1, compared to the previous years, it can be said that improvement in general has taken place.

A Study on the Calculation of Standard Data for Energy Use Plan of Industry Complex (산업단지 에너지사용계획을 위한 표준데이터 산정 연구)

  • Suh, Kwang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.101-109
    • /
    • 2014
  • The Consultation about Energy Use Plan is prescribed by the Energy Use Rationalization Act. This study calculated the Standard Data for Energy Use Plan of Industry Complex by the 9th Korean Standard Industrial Classification Divisions so that the energy demand reflecting the industrial technology change and characteristics of Manufacturing Divisions would predict. To achieve this aim, analysis on thousands of data in Energy Consumption Report Forms reported from industries which annual consumption of energy exceeds 2,000toe from 2009 to 2010 was carried out. The results showed that calculated overall mean fuel basic unit decrease, electricity basic unit increase and energy basic unit increase compared to that of the Notification No. 2002-130 of the Ministry of Commerce, Industry and Energy, therefore it means that heat source of energy facilities transferred from fuel to electricity. Also resultingly suggests that the related notification, code etc. are amended as soon as possible.

The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software (ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.

Reduction of Melting Energy by Customized Charging of Press Scrap (생압고철의 맞춤형 장입을 통한 용해에너지 절감)

  • Lee, Sang-Hwan
    • Journal of Korea Foundry Society
    • /
    • v.41 no.4
    • /
    • pp.342-348
    • /
    • 2021
  • Almost all ferrous foundries use press scrap as the main charge material. In this study, we tried to reduce the melting energy by optimizing the shape and size of press scrap. The experiment was conducted using 3t/h medium frequency induction melting furnaces at two foundries. In the case of the improved condition, customized press scrap was used for initial charging, and small press scrap was used for additional charging. The energy reduction effect of the improved condition was enhanced by reinforcing the cleaning process of the return scrap surface. The reduction ratios of the melting energy basic unit by the improved condition at the two foundries were almost the same (23.3 and 23.9%). The improved condition was very effective in both foundries with different basic unit levels. The reasons for energy reduction and the economic effects of the improved condition were described.

Rapid and Low-Energy Melting of Cast Iron using Small Scrap Steel as a Charge Material - Part II. Application of Small Scrap Steel in Low-Frequency Induction Melting Furnace and Energy Characteristics (소형 고철 장입재를 활용한 신속 저에너지 주철 용해 - Part II. 저주파 용해로 적용 및 에너지 측면 특징)

  • Lee, Sang-Hwan
    • Journal of Korea Foundry Society
    • /
    • v.41 no.2
    • /
    • pp.132-138
    • /
    • 2021
  • In this study, the power basic units to produce cast iron by using the press and shredded scrap are compared in 16t/h low-frequency induction melting furnace. Charging the shredded scrap instead of the press scrap was confirmed that the power basic unit is improved by about 5%. The energy characteristics according to the shape and size of scrap steel and the effect of the furnace size were investigated. Finally, the strategy to improve the utilization of this technology was proposed.

A study on the Energy Consumption and the Greenhouse gas Emission intensity of Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Ju-Young;Kim, Yu-Lan;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to provide a fundamental data for reducing energy consumption and greenhouse gas emission of detached houses by investigating the energy consumption characteristic of detached houses in Daegu. Although the ratio of the detached houses decreases, the detached houses are common dwelling form next to apartments. Nevertheless the study about the energy consumption of detached houses has been insufficient compared apartments. There is a necessity which will investigate the energy consumption characteristic of detached houses. Because that with the building quality which is various form is different from apartments. This study investigate construction and equipment conditions and analyzing effective factors on energy consumption of detached houses. And this study draw up the energy consumption unit and emission factors unit for greenhouse gas of detached houses. This study represent a basic report for energy consumption reduction and helps effective use of energy.

  • PDF

A Study on Energy Consumption and Estimation of CO2 from Re-bar Production (철근 생산과정의 에너지 사용량 및 CO2배출량 산출에 관한 연구)

  • Choi, Jae-Hwi;Lee, Dong-Hoon;Kwon, Gi-Deoc;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.101-109
    • /
    • 2010
  • As global warming progresses, nations around the world are trying to reduce emission of $CO_2$ that accounts for the greatest portion of greenhouse gases. To reduce $CO_2$ emission, it is first necessary to estimate $CO_2$ emission of each industry. Government authorities estimate basic unit of $CO_2$ emission from re-bar that is one of the key materials of construction industry with LCA technique (Life Cycle Assessment). However, basic unit of $CO_2$ emission varies from organization to organization. The Ministry of Land, Transport and Maritime Affairs (2004) publishes it 3.48($TCO_2/ton$) and 0.30($TCO_2/ton$) with input-output analysis while the Korea Environmental Industry & Technology Institute (2008) defines it as 0.34($TCO_2/ton$) with process analysis, which indicates ambiguity in application of basic unit of $CO_2$emission. Based on the analysis of conventional methods used for estimating the $CO_2$ emission, therefore, this research suggests existing problems on the methods and focuses on proposing an strategy to effectively estimate the basic unit of $CO_2$ emission according to the energy consumption limited to the re-bar production in steel mill in order to overcome the problems. The result of this research is expected to be helpful in calculating and reducing $CO_2$ emission.

Analysis of City Gas Consumption by Borough and Usage in Busan (부산시 구별 용도별 도시가스 소비 특성 분석)

  • Park, Yool;Park, Jong-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.65-71
    • /
    • 2011
  • Recently, central and local governments of Korea have established and implemented various energy policies such as making energy map of city level and establishment of environment friendly city plan to materialize low carbon green city. To implement effectively these policies, however, conditions of energy consumption by each administrative district and each usage have to be verified exactly. This study is aimed to suggest a basic data for planing energy policy and energy demand prediction of city level by analyzing energy consumption unit and conditions of city gas by borough and usage in Busan.

A Study on the Greenhouse Gas Intensity of Building Groups and Regional in Korea (국내 에너지다소비건물의 용도별.지역별 온실가스 배출원단위분석 연구)

  • Lee, Chung-Kook;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • Our country set the mid-term reduction goal of greenhouse gases up to 2020 in accordance with Bali roadmap agreed in 2007 through the negotiation with UNFCCC in 2009 and specified the proper goal as by the Basic Act on Green Growth that went into effect at April, 2010. First of all the enlargement of green building construction has been suggested as a worldwide strategy to achieve the green house gas reduction. Building area is one of most important sectors for the countermeasure of climate change agreement and the achievement of national green house gas reduction goal and the need to reduce its green house gases has been increased accordingly. The objective of the study is to examine the status and characterization of mass energy consumption local governmental buildings' green house gas emissions depending on usage (hotel, school, apartment, hospital) through the green house gas emission source unit analysis. The result indicated that the energy source unit was proportional to green house gas source unit and hotel showed the highest green house gas emission source unit per open area of construction unit, followed by hospital, apartment, and then school. In case of apartment, green house gas emission source unit per open area of construction unit decreased as year went on. Meanwhile school building showed a striking increase in the annual energy source unit.

Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight (경량화용 박육부재의 형상비가 압궤특성에 미치는 영향)

  • 정종안;김정호;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF