• 제목/요약/키워드: Energy and Consumption

Search Result 6,389, Processing Time 0.398 seconds

Energy Saving Potential and Indoor Air Quality Benefits of Multiple Zone Dedicated Outdoor Air System

  • Lee, Soo-Jin;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제8권1호
    • /
    • pp.71-82
    • /
    • 2019
  • The purpose of this study is to evaluate the indoor air quality (IAQ) and energy benefits of a dedicated outdoor air system (DOAS) and compare them with a conventional variable air volume (VAV) system. The DOAS is a decoupled system that supplies only outdoor air, while reducing its consumption using an enthalpy wheel. The VAV system supplies air that is mixed outdoor and transferred indoor. The VAV has the issue of unbalanced ventilation in each room in multiple zones because it supplies mixing air. The DOAS does not have this problem because it supplies only outdoor air. That is, the DOAS is a 100% outdoor air system and the VAV is an air conditioning system. The transient simulations of carbon dioxide concentration and energy consumption were performed using a MATLAB program based on the thermal loads from the model predicted by the TRNSYS 18 program. The results indicated that when the air volume is large, such as in summer, the distribution of air is not appropriate in the VAV system. The DOAS however, supplies the outdoor air stably. Moreover, in terms of annual primary energy consumption, the DOAS consumed approximately 40% less energy than the VAV system.

서울 지역 대학생의 고카페인 에너지음료 소비 실태 조사 (Survey on the High-Caffeine Energy Drink Consumption Status of University Students in Seoul)

  • 유현숙;심기현
    • 동아시아식생활학회지
    • /
    • 제24권3호
    • /
    • pp.407-420
    • /
    • 2014
  • 본 연구는 대학생의 고카페인 에너지음료 실태 조사를 통해서 무분별한 고카페인 에너지음료 섭취에 대한 문제점을 해결하고자 서울 지역의 대학생 300명을 대상으로 고카페인 에너지음료 섭취 실태에 대해 조사하였으며, 조사 결과는 다음과 같다. 조사 대상자의 성별은 남성은 35%, 여성은 65%인 것으로 나타났고, 학년으로 대학생 4학년이 38.3% 가장 많았으며, 한 달 평균 용돈은 50만원 이상 55.0%로 가장 많았고, 한 달 음료 구입비 73.0% 가장 많았다. 고카페인 에너지음료 섭취 경험은 전체 학생의 68.7%가 에너지음료를 마셔본 경험이 있었으며, 여성(63.6%)에 비해 남성(78.1%)이 에너지음료를 섭취한 경험이 높은 것으로 나타났다(p<0.05). 고카페인 에너지음료는 주로 공부할 때 마시는 학생이 가장 많았으며, 성별에 상관없이 공부할 때에 가장 많이 마시는 것으로 나타났다(p<0.05). 고카페인 에너지음료의 섭취 횟수는 1~6회/년 미만이 가장 많았고, 여성은 남성에 비해 거의 마시지 않는다는 응답이 많았다(p<0.05). 고카페인 에너지음료 구입 장소로 편의점이 가장 많았으며, 고카페인 에너지음료에 대한 정보 경로는 TV나 라디오, 신문, 잡지 등의 광고를 통해 알게 된 학생이 가장 많았다. 고카페인 에너지음료 구매 시 영향 요인으로 '맛'이 가장 크게 영향을 미친다는 반응을 보였다. 고카페인 에너지음료 섭취 시 부작용과 문제점에서 에너지음료 섭취 후 심장 두근거림을 부작용으로 느낀 경우가 가장 많았고, 고카페인 에너지음료 섭취 시 문제점으로 중독 증상이라고 가장 많이 응답하였다. 이상의 본 연구 결과를 토대로 고카페인 에너지음료의 섭취에 다음과 같이 제안하고자 한다. 최근 들어 에너지음료 섭취가 늘어나고 있는 대학생들이 에너지음료가 고카페인 음료라는 것을 인지하고 있으면서도 공부를 위해서 이들 고카페인 에너지음료를 무분별하게 과량 섭취하는 것이 문제이므로 카페인 과량 섭취 시 부작용을 인식시키고, 올바른 에너지음료에 대한 구매와 구입법, 음용법 등을 알려서 계층별 카페인의 1일 섭취 허용량만큼만 섭취할 수 있도록 해야 한다. 또한 에너지음료의 카페인 함유량을 제한하고 효율적인 규제방안이 반드시 필요할 것으로 사료된다. 현재 정부에서는 카페인 과량 섭취의 위험성을 인식하고 '식품 표시법'을 개정하여 '카페인 함유'라는 문구와 함께 고카페인 음료에 대해서는 카페인 함유량 표시를 의무화하고 있으며, 올해 1월 말부터 '어린이 식생활 안전관리 특별법'을 개정하여 학교내 매점이나 어린이 기호 식품 우수 판매 업소에서 에너지음료를 판매하지 못하게 하고, 특정시간대의 방송광고도 제한하도록 하고 있지만, 소비자 단체와 전문가들을 중심으로 그 실효성에 대해서는 의문을 제기하고 있는 경우가 많으므로, 카페인 함유량 표시 의무화 외에도 정부 차원의 엄격한 규제 및 관리 방안을 통해서 고카페인 에너지음료의 카페인 함유량을 제한할 수 있도록 하는 효율적인 규제방안이 반드시 필요하다. 특히 고카페인 에너지음료의 소비층이 청소년에서 어린이와 대학생, 직장인으로 확대되고 있는 현실에서 일부 취약계층에 대한 에너지음료 판매 제한뿐만이 아니라, 대학생이나 성인들을 대상으로 한 술집 등에서의 판매 증가와 주류와 섞어 마시는 등의 잘못된 음용 방법 개선을 위해 판매 장소와 판매 품목 제한과 같은 정부 차원의 보다 효과적인 규제 및 관리 방안을 마련해야 할 것이다. 특히 한국소비자원의 조사 결과에서와 같이 에너지음료를 섭취한 적이 있는 대학생 중에 상당수가 알코올과 섞어서 마실 정도로 이러한 잘못된 음주 습관이 대학가의 음주 문화로 자립잡고 있으므로, 잘못된 음주 습관으로 인한 위험성을 적극적으로 알릴 필요가 있다. 또한 에너지음료와 같은 기호식품의 소비에 있어서는 소비자의 알 권리를 인식하고, 합리적으로 제품을 선택할 수 있도록 대학생들을 대상으로 한 식생활 교육이 자연스럽게 이루어져야 할 필요성도 있겠다.

관광호텔의 호텔특성 및 입지특성에 따른 에너지사용량 분석 (Analysis of the Energy Consumption of Tourism Hotels in Relation to Individual and Locational Characteristics)

  • 박혜란;김현수;최열
    • 대한토목학회논문집
    • /
    • 제42권4호
    • /
    • pp.571-579
    • /
    • 2022
  • 본 연구는 부산·울산·경남 지역의 관광호텔을 대상으로 에너지사용량과 이들의 개별적인 호텔특성 및 입지특성 간의 관계를 실증분석하였다. 복합적인 관계식 도출을 위해 다중회귀모형에서부터 다수준회귀분석(multi-level regression analysis)으로 모형을 확장하였고, 이를 통해 건축물의 개별적인 특성만을 고려한 대부분의 선행연구에서 나아가 호텔이 위치한 지역의 입지적 특성과 호텔-지역 간 위계적 구조를 고려하여 좀 더 개선된 모형을 도출하였다. 분석결과에 따르면, 호텔의 규모, 연한, 서비스 등급과 같은 개별적인 특성은 에너지사용량을 설명하는 주요 변수이고, 그들의 영향은 지역적으로 유의한 차이를 보이는 것으로 나타났다. 또한, 중심상업지에 인접하거나 다수의 관광호텔이 밀집한 지역에 위치할수록 에너지사용량은 달라지는 것으로 나타났으며, 이러한 입지특성 또한 개별호텔의 에너지사용량을 설명함에 있어 주요한 요인임을 확인하였다. 이와 같은 결과는 건축물단위의 에너지정책과 소비수준이 높고 에너지 집약시설이 밀집한 지역에 대한 지역단위의 에너지정책이 함께 고려될 필요성을 시사하며, 관광산업의 지속가능성을 높이기 위한 지역적 책임을 제언한다.

정량화 시뮬레이션 모델을 활용한 단계적인 건축물에너지효율등급 향상 방안 (Stepwise Technique for Improving Building Energy Efficiency Rating Utilizing Quantified Simulation Model)

  • 김기석;김유민;김종성;오세규
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.65-73
    • /
    • 2014
  • Due to the Climate change and resource shortage by global warming, various problems are rising and getting worse around the world. Many countries are doing the considerable efforts to reduce greenhouse gas emissions. The government of South Korea also plans to decrease greenhouse gas emission, the various pilot projects are underway, which includes obligation of energy efficiency 1st rating and greenhouse gas target management system of public buildings. In particular, luxurious government office buildings and energy-wasting public building have issued and emerged as a social problem. Energy efficiency improvement of the existing public office buildings are becoming an important issue recently. This study is proposed the step-by-step energy improvement model according to the building energy efficiency rate in order to reduce the energy consumption. To attain this end, I set up a base model by analyzing the current architectural conditions of the existing public office buildings and grasped the specific properties of building energy consumption through energy simulations. Furthermore, I suggested phased reduction prototypes for the reduction target of energy consumption by applying the methods of the zero energy building plan. This study is expecting that prototypes would give directions when it comes to planning the implementation policy of phased building plan factors, according the building energy consumption reduction goal in the existing public office buildings which are the subject of building energy target management system.

실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가 (Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing)

  • 류성룡;정창헌;조현
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

복합열원 히트펌프 최적 제어를 위한 열원에 따른 히트펌프 성능 및 에너지 소요량 패턴 비교 (Comparison of Heat Pump Performance and Energy Consumption Patterns according to Heat Sources for Optimal Control of Multi-Source Heat Pumps)

  • 고유진;박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.31-38
    • /
    • 2020
  • The investment in the technology of using a combined heat source is insufficient, which utilizes the advantages of various heat sources to maximize the potential energy and at the same time increases the performance of the heat pump. In this study, as basic data for the development of a high-efficiency hybrid heat pump system that actively connects and uses various heat sources, simulations were conducted for the heat pumps in two cases where geothermal and hydrothermal heat were applied respectively. In May, COP increased by about 27.3% compared to geothermal heat. In February, the COP percentage decrease of hydrothermal heat compared to geothermal heat is -6.9%. In May, total energy consumption can be reduced by 21.1% when hydrothermal is applied compared to geothermal heat. In February, the total energy consumption increases by 3.4%.

An Energy-Efficient Multicast Algorithm with Maximum Network Throughput in Multi-hop Wireless Networks

  • Jiang, Dingde;Xu, Zhengzheng;Li, Wenpan;Yao, Chunping;Lv, Zhihan;Li, Tao
    • Journal of Communications and Networks
    • /
    • 제18권5호
    • /
    • pp.713-724
    • /
    • 2016
  • Energy consumption has become a main problem of sustainable development in communication networks and how to communicate with high energy efficiency is a significant topic that researchers and network operators commonly concern. In this paper, an energy-efficient multicast algorithm in multi-hop wireless networks is proposed aiming at new generation wireless communications. Traditional multi-hop wireless network design only considers either network efficiency or minimum energy consumption of networks, but rarely the maximum energy efficiency of networks. Different from previous methods, the paper targets maximizing energy efficiency of networks. In order to get optimal energy efficiency to build network multicast, our proposed method tries to maximize network throughput and minimize networks' energy consumption by exploiting network coding and sleeping scheme. Simulation results show that the proposed algorithm has better energy efficiency and performance improvements compared with existing methods.

마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Micro Form Admixture)

  • 박영신;김정호;전현규;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 최근 전세계는 급격한 기후조건과 환경변화에 의해 냉난방 에너지 사용이 증가되고 있으며 이는 화석 연료 사용량 증가와 함께 $CO_2$ 배출량 상승, 지구 온난화 등 환경과 에너지에 대한 수많은 문제를 유발하고 있어 세계 각국은 온실가스 배출 및 에너지 소비 감소를 위한 대응책을 마련하고 있다. 우리나라 또한 정부의 '저탄소 녹색 성장' 및 '친환경 주택 건설기준 및 성능' 등의 정책을 선포하는 등 건물 부분에 있어 환경과 에너지 관리에 대한 노력을 하고 있다. 우리나라의 총 에너지 소비량 중 건물 부문이 차지하는 비율은 약 25%에 달하며 다른 산업 분야에 비해 연간 에너지 소비 증가율이 높은 편이다. 건물에서 에너지 손실이 가장 큰 부위는 외피로서, 이 부분의 에너지 손실을 감소하기 위한 연구가 활발히 진행되고 있으나 이는 대부분 창호 및 단열재를 사용한 연구이며 건물 외피의 70% 이상을 차지하고 있는 콘크리트에 대한 연구는 미미한 실정이다. 따라서 건물의 에너지 손실을 최소화하기 위해서는 콘크리트 자체에서 단열성능을 확보할 수 있어야 하며 이에 대한 연구가 필요하다. 따라서 본 연구는 콘크리트의 단열성능을 확보하면서 구조용으로 사용이 가능한 콘크리트를 개발하기 위한 실험을 진행하였다. Test 1의 실험결과로써, Micro Foam Admixture (MFA)를 사용한 콘크리트는 슬럼프 경시변화가 개선되었으며, MFA의 혼입율을 증가할 경우 압축강도는 감소되고 열전도율은 증가되는 결과를 나타내었다. Test 2의 실험결과에서는 물시멘트비 변화시 물시멘트비 증가에 따라 압축강도는 감소하였고 열전도율은 증가하였다. 그러나 잔골재율 변화에 대한 물성 및 열적 특성은 큰 차이를 나타내지 않았다.

멀티프로세서 시스템을 위한 동적 전압 조절 기반의 효율적인 스케줄링 기법 (An Efficient Scheduling Method based on Dynamic Voltage Scaling for Multiprocessor System)

  • 노경우;박창우;김석윤
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.421-428
    • /
    • 2008
  • The DVS(Dynamic Voltage Scaling) technique is the method to reduce the dynamic energy consumption. As using slack times, it extends the execution time of the big load operations by changing the frequency and the voltage of variable voltage processors. Researches, that controlling the energy consumption of the processors and the data transmission among processors by controlling the bandwidth to reduce the energy consumption of the entire system, have been going on. Since operations in multiprocessor systems have the data dependency between processors, however, the DVS techniques devised for single processors are not suitable to improve the energy efficiency of multiprocessor systems. We propose the new scheduling algorithm based on DVS for increasing energy efficiency of multiprocessor systems. The proposed DVS algorithm can improve the energy efficiency of the entire system because it controls frequency and voltages having the data dependency among processors.

남부지역 주거건물의 외피단열변화에 따른 에너지소비량 예측 (Prediction of the Amount of Energy Consumption by Variation in Envelope Insulation on a Detached House in Southern Part of Korea)

  • 문진우;한승훈;오세규
    • 한국주거학회논문집
    • /
    • 제22권1호
    • /
    • pp.115-122
    • /
    • 2011
  • This study aimed at quantifying the impact of envelope insulation on energy consumption for thermal controls in residential buildings in southern part of Korea. A series of parametric simulations for a range of R-values of walls, roof, floor, and windows were computationally conducted for a prototypical Korean detached house. Analysis revealed that the total amount of heat gain was larger than that of heat loss, while the amount of energy for cooling was smaller than that for heating due to the difference of system efficiency; the envelope heat transfer was more significant for the heat loss, thus, the increase of the envelope insulation was more effective to reduce heating load; and there were certain levels of envelope insulation after which the energy saving effect was not significant. These findings are expected to be a fundamental database for the decision of proper insulation level in Korean residential buildings.