• 제목/요약/키워드: Energy Window

검색결과 693건 처리시간 0.021초

공동주택의 에너지 자립을 위한 핵심요소기술의 에너지 성능평가 (Energy Performance Evaluation of Zero Energy Technologies for Zero Energy Multi-House)

  • 윤종호;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.161-167
    • /
    • 2007
  • Zero Energy Multi-House(ZeMH) signifies a residential building which can be self sufficient with just new and renewable energy resources without the aid of any existing fossil fuel. For success of ZeMH, various innovative energy technologies Including passive and active systems should be well integrated with a systematic design approach. The first step for ZeMH is definitely to minimize the conventional heating and cooling loads over 50% with major energy conservation measure and passive solar features which are mainly related to building design components such as super-insulation, super window, including infiltration and ventilation issues. The purpose of this study is to analyze the thermal effect of various building design components in the early design of ZeMH. The process of the study is presented in the following. 1) selection reference model for simulation 2) verification of reference model with computer simulation program(ESP-r 9.0). 3) analysis of effect according to insulation-thickness, kinds of windows, rate of infiltration. and The simulation results indicate that almost 50% savings of conventional heating load in multi-house can be achieved with the optimum design of building components such as super insulation, super window, infiltration, ventilation.

기존 노후건축물의 최적 리모델링 개선안 연구 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;오세민
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.207-216
    • /
    • 2014
  • 에너지손실을 분석해 보면 열전달에 의한 손실과 공기유동에 의한 손실로 구분할수 있다. 열전달은 외벽, 지붕, 바닥의 열관류율에 의한 손실로 기존건축물의 가장 취약한 부분의 한 요소이다. 이런 손실을 방지 하려면 창을 포함한 외벽 전체의 평균 열관류율을 지역 기준값 이상으로 올리고 창의 기밀성을 확보함에 따라 방지 할수 있다. 노후건축물의 가장 취약한 부분이 외벽과 창호 이지만 출입문을 통한 침기량은 연돌효과에 의해 층계단을 타고 올라감과 동시에 각층의 공기를 흡입하여 더큰 유동을 잃으켜 층의 단열성 까지 취약하게 만드는 구조로 되어 있다. 현장 조사를 통한 진단과 에너지 개선처방이 제시될 때 반드시 건물전체에 대한 진단과 각층 부분에 대한 개선안이 함께 제출되어 단순히 창 교체만 하면 에너지절감을 이룰수 있다는 착각에서 벗어나야 할 것이다.

창호일체형 태양열 집열기 (Window Integrated Solar Collectors)

  • 박성배;임성환;박만귀
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구 (A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types)

  • 최태환;김태연;이승복
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향 (Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions)

  • 술타나 아즈미리;김정태
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.

소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측 (Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office)

  • Gu, Renyan
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.79-89
    • /
    • 2021
  • 본 연구는 다른 창가 방향에 따라 소규모 개인 사무실의 바닥과 천장의 수평 일광 분포를 분석하였다. 시뮬레이션에는 블라인드를 추가하여 다양한 일광 조도를 분석하고 비교할 수 있는 세 가지 음영 조건을 설정했다. 일광 조도 시뮬레이션을 위한 소프트웨어는 Relux였다. 실험 결과 창가에서 1m 떨어진 곳에서 조도 값이 가장 높았고 거리가 가까울수록 조도 값이 높았다. 바닥과 천장에서는 조도 차이가 12월과 6월에 각각 가장 크고 작았다. 실내 조도 값은 블라인드가 없을 때 가장 높았고, 남향 조건에서는 조도의 45°와 수평 블라인드의 차이가 가장 컸다. 북쪽 조건에서는 45°와 무 블라인드가 실내 조도에 가장 적은 영향을 미치며, 조도가 더 고르게 분배되었다.

박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구 (An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System)

  • 김빛나;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

공동주택 벽체 반사율에 따른 PV창호시스템 발전효율 분석 (Analysis of Generating Efficiency in PV Window System consequent on Apartment House Wall Reflectivity)

  • 최두성;안준호;전흥찬;도진석
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.31-39
    • /
    • 2016
  • This study did quantitative comparative evaluation of changes in generation consequent on reflectivity of the protruding wall near the widow in case of application of PV window system to an apartment house. To be concrete, this study did comparative analysis of the generation of (B) through the process of composing Mock-up (A)comprising the protruding window near the window and Mock-up(B) free of nearby wall interference, and giving change to the reflectivity of the wall (Case_1~3). The analysis result showed that the difference in generation was slight in case solar radiation was less than 10,000Wh in all three conditions. On the contrary, in case solar radiation was more than 10,000 Wh, the generation as against Module(B), was analyzed to be 87~91% in Case_1(5% reflectivity), 18~60% in Case_2(85% reflectivity), and 16~71% in case_3(93% reflectivity), respectively.

실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석 (A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds)

  • 현인탁;이재호;윤여범;이광호
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

DEA를 이용한 기업의 Business Intelligence 시스템 도입 효율성에 대한 비교 평가 연구 (The Efficiency Analysis of Firms Having Established a Business Intelligence System Using DEA/Time-Window Analysis)

  • 백성현;박광호;김태영
    • 경영정보학연구
    • /
    • 제17권3호
    • /
    • pp.113-133
    • /
    • 2015
  • 본 논문은 BI 시스템을 도입하여 사용하고 있는 기업들을 'IT통신 업종', '전기전자 업종', '에너지 화학 업종', '자동차 기계 장비 업종', '식품 소비재 업종' 과 같이 5개 산업 업종으로 구분 하여 BI 시스템을 도입한 기업의 효율성을 DEA 기법의 CCR 모형과 BCC 모형을 활용하여 평가하였으며, 특히 Time-Window 기법을 적용하여 BI 도입 후 기간별로 효율성의 변화 추이를 분석하였다. 즉 BI 시스템을 도입한 기업들의 상대적인 효율성을 비교하여 순위를 매기고, 분석 시 BI 도입 시점으로부터 시간이 흐른 것을 토대로 비교 평가하는 Time Window 기법을 활용하여 BI를 도입한 지 오래된 기업과 그렇지 않은 기업을 차별화하여 의미 분석하였다. 분석 결과는 에너지 화학 산업에서 BI 도입 후 효율성 제고가 두드러졌고 전기 전자 산업의 효율성이 꾸준히 안정화되어 가고 있는 것으로 분석되었다.