• Title/Summary/Keyword: Energy Values

Search Result 4,829, Processing Time 0.035 seconds

Experimental study on Effects of Spacers on Natural Convection from a Horizontal Annulus (수평환상공간(水萍環狀空間)의 자연대류(自然對流)에서 격판(隔板)의 영향에 관한 실험적(實驗的) 연구(硏究))

  • Chung, T.H.;Kim, S.J.;Lee, B.C.;Kwon, S.S.
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.66-72
    • /
    • 1988
  • Natural convection in a horizontal annulus with spacers has been studied on the effects of diameter ratio and Rayleigh numbers and position of spacers by experimental method. In case of vertical spacers, the local spacer Nusselt numbers show positive values on the lower spacer, but negative values on the upper spacer. In case of horizontal spacers, the local spacer Nusselt numbers show positive values on the upward surface of spacer, but negative values on the downward surface of spacer. The mean tube Nusselt numbers and mean cylinder Nusselt numbers with vertical spacer are increased 10% and 2.1%, respectively by those of horizontal spacer.

  • PDF

Potential Feeding Value of Deoiled Rice Bran by Japanese Quails. 1. The Metabolisable Energy Content

  • Bhanja, S.K.;Verma, S.V.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.5
    • /
    • pp.680-683
    • /
    • 2001
  • The apparent metabolisable energy (AME) and N-corrected ME (AMEn) of deoiled rice bran (DORB) were determined with adult quails at 6 and 10- week of age. The DORB obtained from two types of extraction process, Batch (DORB-B) and the Continuous (DORB-C), was each included in a practical type of the reference diet at 20 or 40% level. The analysed crude protein, ether extract, total ash, calcium, phosphorus, glucose and starch content of DORB-B and DORB-C were found at 19.0, 0.79, 17.05, 0.11, 1.92, 2.3, 11.22, and 15.02, 1.56, 13.0, 0.40, 2.76, 2.16, 19.0, respectively. The level of inclusion of DORB in diet appeared to exert a significant effect on the AME and AMEn values. When bioassayed at 20% inclusion level the DORB was found to have a significantly (p<0.01) lower value than that obtained at 40% inclusion level. However, no significant effect of age of quails on the AME values of DORB was evident. The ME bioassays with quails gave significantly (p<0.01) higher AME values for DORB-C than DORB-B thereby indicating that the continuous system of solvent extraction of rice bran is superior to the batch system from this point of view. The AME value of DORB predicted from its chemical composition also revealed that the DORB-C contained approximately 15% more energy than that in DORB-B.

Loss Analysis by Impeller Blade Angle in the S-Curve Region of Low Specific Speed Pump Turbine

  • Ujjwal Shrestha;Young-Do Choi
    • New & Renewable Energy
    • /
    • v.20 no.2
    • /
    • pp.35-43
    • /
    • 2024
  • A pump turbine is a technically matured option for energy production and storage systems. At the off-design operating range, the pump turbine succumbed to flow instabilities, which correlated with the pump turbine geometry. A low specific speed pump turbine was designed and modified according to the impeller blade angle. Reynolds-Average Navier-Stokes is carried out with a shear stress transport turbulence model to evaluate the detailed flow characteristics in the pump turbine. The impeller blade inlet angle (𝛽1) and outlet angle (𝛽2) are used to evaluate hydraulic loss in the pump turbine. When 𝛽1 changed from low to high value, the maximum efficiency is increased by 4.75% in turbine mode. The S-Curve inclination is reduced by 8% and 42% for changes in 𝛽1 and 𝛽2 from low to high values, respectively. At α = 21°, the shock loss coefficient (𝜁s) is reduced by 16% and 19% with increases of 𝛽1 and 𝛽2 from low to high values, respectively. When 𝛽1 and 𝛽2 values increased from low to high, the impeller friction coefficient (𝜁f) increased and decreased by 20% and 8%, respectively. Hence, the high 𝛽2 effectively reduced the loss coefficient and S-Curve inclination.

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

Effect of dietary β-mannanase on productive performance, egg quality, and utilization of dietary energy and nutrients in aged laying hens raised under hot climatic conditions

  • Kim, Moon Chan;Kim, Jong Hyuk;Pitargue, Franco Martinez;Koo, Do Yoon;Choi, Hyeon Seok;Kil, Dong Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1450-1455
    • /
    • 2017
  • Objective: The objective of this experiment was to investigate the effect of dietary ${\beta}-mannanase$ on productive performance, egg quality, and utilization of dietary energy and nutrients in aged laying hens raised under hot climatic conditions. Methods: A total of 320 84-wk-old Hy-line Brown aged laying hens were allotted to one of four treatments with eight replicates in a completely randomized design. Two dietary treatments with high energy (HE; 2,800 kcal/kg nitrogen-corrected apparent metabolizable energy [$AME_n$]) and low energy (LE; 2,700 kcal/kg $AME_n$) were formulated. Two additional diets were prepared by adding 0.04% (MN4) or 0.08% ${\beta}-mannanase$ (MN8) to LE treatment diets. The feeding trial was conducted for 28 d, covering a period from July to August in South Korea. The average daily room temperature and relative humidity were $29.2^{\circ}C$ and 83%, respectively. Results: Productive performance, egg quality, and cloacal temperature were not influenced by dietary treatments. The measured $AME_n$ values for MN8 diets were similar to those for HE diets, which were greater (p<0.05) than those for LE and MN4 diets. However, the $AME_n$ values for MN8 diets did not differ from those for LE and MN4 diets. Conclusion: The addition of ${\beta}-mannanase$ to low energy diets increases energy values for diets fed to aged laying hens. However, this increase has little positive impacts on performance and egg quality. These results indicate that dietary ${\beta}-mannanase$ does not mitigate the heat stress of aged laying hens raised under hot climatic conditions.

Effect of Working Fluids on the Thermal Behavior of a Bi-directional Solar Thermal Diode (작동유체가 양방향성 태양열 열다이오드의 열성능 변화에 미치는 영향 분석)

  • Ko, Yung-Joo;Lee, Heon-Ju;Chun, Won-Gee;Chen, Kuan;Lim, Sang-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.9-17
    • /
    • 2008
  • An experimental investigation has been carried out to study the effects of different working fluids on the behavior and thermal performance of a hi-directional thermodiode. The thermodiode was made up of two rectangular loops mounted between a collector plate and a radiator plate. Rotatable joints between the horizontal and inclined segments of the loops enable easy alteration of the direction of heat transfer. The loops and the tank were filled with a working fluid for effective heat transfer when the thermodiode was forwarded biased. Six different working fluids were tested with thermal conductivity values ranging from 0.1 to $0.56W/m-^{\circ}C$, thermal expansion coefficient values ranging from $1.8\;{\times}10^{-4}$ to $1.3\;{\times}\;10^{-3}\;K^{-1}$, and kinematic viscosity values ranging from $0.65\;{\times}\;10^{-6}$ to $100\;{\times}\;10^{-6}\;m^2/s$. Especially, mixtures of $Al_2O_3$ (30nm Particle) in deionized water have been tested for the volumetric ratios of 0.01, 0.02, 0.03, 0.1, 0.2%. Each experiment was carried out after the loop was filled with a working fluid for effective heat transfer and the thermodiode was forwarded biased. The solar thermodiode was heated by a radiant heater consisting of 20 halogen lamps that generated a heat flux of about $1000\;W/m^2$ on the collector surface. Results are given in terms of temperature development in different parts of the loop as heat is delivered from its hot end to the surrounding atmosphere by the radiator made of copper plates.

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

Assessment of Basal Energy Expenditure in Normal Healthy Volunteers and Patients Receiving TPN by Bioelectrical Impedance Analysis (Bioelectrical Impedance Analysis를 통한 건강한 성인과 TPN환자의 기초대사량 산출)

  • Son, Eun Sun;Kim, Choong Bai;Suh, Okkyung;Shin, Hyun Taek;Lee, Suk Hyang
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.1
    • /
    • pp.19-26
    • /
    • 1999
  • Adequate nutrition is important in maintaining optimal health. Malnutrition can expose individual to increased risks of morbidity and mortality. The purposes of this study were to determine the basal energy expenditure (BEE) of Korean healthy subjects and TPN patients using Bioelectrical Impedance Analysis (BIA) method and to compare these values with those predicted by Harris-Benedict equation (H-B). BEE values measured by BIA were compared with predicted BEE values by the H-B formula in 59 clinically stable TPN patients and 65 healthy volunteers. In healthy volunteers and TPN patients, statistically significant differences were not shown between the BEE values measured by BIA (1392.5 Kcal and 1325.9 Kcal) and those predicted by H-B formula (1384.1 Kcal and 1270.1 Kcal). In male volunteers, statistically significant differences were not shown between BEE values measured by BIA (1670.7 Kcal) and the H-B formula (1550.9 Kcal), but in female volunteers, statistically significant differences were shown between BEE values measured by BIA (1194.8 Kcal) and the H-B formula (1265.6 Kcal). In male TPN patients, statistically significant differences were shown between BEE values measured by BIA (1453.5 Kcal) and the H-B formula (1335.9 Kcal), but in female TPN patients, statistically significant differences were not shown between BEE values measured by BIA (1126.4 Kcal) and the H-B formula (1167.2 Kcal). In normal healthy volunteers, $90.8\%$ of BEE values measured by BIA and in TPN patients $89.8\%$ of BEE values measured by BIA were within $15\%$ of BEE values predicted by the H-B formula in non-obese subjects. In conclusion, BEE values predicted by H-B formula or measured by BIA can be applied to non-obese Koreans. However, these values should be confirmed with Indirect calorimetry for Koreans.

  • PDF

Influence of Protein and Energy Level in Finishing Diets for Feedlot Hair Lambs: Growth Performance, Dietary Energetics and Carcass Characteristics

  • Rios-Rincon, F.G.;Estrada-Angulo, A.;Plascencia, A.;Lopez-Soto, M.A.;Castro-Perez, B.I.;Portillo-Loera, J.J.;Robles-Estrada, J.C.;Calderon-Cortes, J.F.;Davila-Ramos, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2014
  • Forty-eight Pelibuey${\times}$Katahdin male intact lambs ($23.87{\pm}2.84$ kg) were used in an 84-d feeding trial, with six pens per treatment in a $2{\times}2$ factorial design arrangement. The aim of the study was to evaluate the interaction of two dietary energy levels (3.05 and 2.83 Mcal/kg ME) and two dietary protein levels (17.5% and 14.5%) on growth performance, dietary energetics and carcass traits. The dietary treatments used were: i) High protein-high energy (HP-HE); ii) High protein-low energy (HP-LE); iii) Low protein-high energy (LP-HE), and iv) Low protein-low energy (LP-LE). With a high-energy level, dry matter intake (DMI) values were 6.1% lower in the low-protein diets, while with low-energy, the DMI values did not differ between the dietary protein levels. Energy levels did not influence the final weight and average daily gain (ADG), but resulted in lower DMI values and higher gain efficiencies. No effects of protein level were detected on growth performance. The observed dietary net energy (NE) ratio and observed DMI were closer than expected in all treatments and were not affected by the different treatments. There was an interaction (p<0.03) between energy and protein level for kidney-pelvic and heart fat (KPH), KPH was higher in lambs fed high energy and high protein diet but not in high energy and low protein diet. The KPH was increased (20.2%, p = 0.01) in high-energy diets, while fat thickness was increased (21.7%, p = 0.02) in high-protein diets. Therefore, it is concluded that dietary energy levels play a more important role in feed efficiency than protein levels in finishing lambs with a high-energy diet (>2.80 Mcal/kg ME). Providing a level of protein above 14.5% does not improves growth-performance, dietary energetics or carcass dressing percentage.

Identification of In-Home Appliance Types Based on Analysis of Current Consumption Using Energy Metering Circuit

  • Tran, Tin Trung;Pham, Trung Xuan;Kim, Jong-Wook
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • One of the important applications of activity sensing in the home is energy monitoring. Many previous methodologies for detecting and recognizing household appliances have been proposed. This paper presents an approach that uses an energy metering circuit (EMC) to classify and identify the various electrical devices in home based on root-mean-square (RMS) consumed current value. EMC gathers the RMS current values created by appliance state transition (e.g., on to off) and apparatus operating process. In this paper, an identification algorithm is proposed to detect a change in current levels using the standard deviation of current signals and their average values. In addition, characteristic of the appliance is extracted concerning four feature parameters concerning the number of current levels, the minimum level, the maximum level, and signal-to-noise ratio (SNR) of them. Experiment results validate the reliable performance of the proposed identification method for 11 representative appliances.