구조단열패널 적용 저에너지주택의 총에너지사용량 평가 (Evaluation on Total Energy Consumption of Low-Energy House with Structural Insulated Panels)

  • 이현주;나환선;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제4권2호
    • /
    • pp.15-24
    • /
    • 2013
  • This project is mainly related to evaluation of total energy consumption of low energy house, the exterior envelope of which was wholly composed of structural insulated panels(SIP). The U-value of applied SIP was in the range of 0.189 to $0.269W/m^2{\cdot}K$ and the U-value of pair glass from 0.78 to $1.298W/m^2{\cdot}K$ was applied for window dependent to its function respectively. For comparison of total energy performance, the energy simulation for pilot house was performed to compare with the control house having insulation criteria of Korean building regulation in 2009. Based on simulation of dynamic energy performance, the pilot house saved 48.3% of annual energy consumption while the control house in 2009 consumed as 85.7GJ/y. In case of heating, the result showed that the energy saving ratio amounted to 76.7%. For $CO_2$ emission, the pilot house diminished approximately 35.4% from $6,208.4kgCO_2$ to $4,009.2kgCO_2$. In payback period to early investment, it was analyzed the pilot house took 7.8 years, when the low energy house built by other insulation method with same thermal perfusion took 11.5 years. From this result, it is considered that the SIP is more effective, economic to Green Home application.

농어촌 주택 표준모델의 냉난방에너지요구량 분석 (Heating and Cooling Energy Demand Analysis of Standard Rural House Models)

  • 이찬규;김우태
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3307-3314
    • /
    • 2012
  • 농어촌 주택 표준모델에 대한 연간 건물에너지요구량을 DesignBuilder를 사용하여 계산하였다. 실내설정온도, 외벽의 열관류율, 창호타입, 환기량을 변화시키며 건물의 설계/운영 변수들이 에너지요구량에 미치는 영향을 분석하였다. 건물의 크기와 상관없이 난방에너지요구량이 냉방에너지요구량보다 더 큰 것으로 나타났다. 단열재 두께를 증가시켜 외벽의 열관류율을 감소시키면 단열효과의 증가로 난방에너지요구량은 감소하지만 냉방에너지요구량이 증가한다. 하지만 외벽의 열관류율 조절을 통한 난방에너지요구량의 절감에는 한계가 있으므로 외부에 직접 노출된 외벽의 면적을 최소화하는 것이 더 효과적인 것으로 판단된다. 계산에 사용된 4가지 창호 중 일반 이중창호가 난방에너지요구량 측면에서 가장 유리한 것으로 나타났다. 침기량은 일정하게 유지하고 단위시간당 환기량을 증가시킨 경우 냉방에너지요구량은 큰 변화가 없었으나 난방에너지요구량이 증가하였다. 실내의 공기질이 만족되는 범위 내에서 환기량을 최소화하는 것이 연간 건물에너지요구량을 줄이는데 유리한 것으로 판단된다.

머신러닝 기법을 활용한 에너지 데이터 분석에 관한 연구 (A Research on the Energy Data Analysis using Machine Learning)

  • 김동주;권성철;문종희;심기도;배문성
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.301-307
    • /
    • 2021
  • After the spread of the data collection devices such as smart meters, energy data is increasingly collected in a variety of ways, and its importance continues to grow. However, due to technical or practical limitations, errors such as missing or outliers in the data occur during data collection process. Especially in the case of customer-related data, billing problems may occur, so energy companies are conducting various research to process such data. In addition, efforts are being made to create added value from data, which makes it difficult to provide such services unless reliability of data is guaranteed. In order to solve these challenges, this research analyzes prior research related to bad data processing specifically in the energy field, and propose new missing value processing methods to improve the reliability and field utilization of energy data.

NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가 (Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201)

  • 임재한;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

Experimental Determination of Concrete Fracture Properties with Modified S-FPZ Model

  • Yon, Jung-Heum;Kim, Tai-Hoon
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.213-219
    • /
    • 2006
  • Modified singular fracture process zone(S-FPZ) model is proposed in this paper to determine a fracture criterion for continuous crack propagation in concrete. The investigated fracture properties of the proposed fracture model are strain energy release rate at a micro-crack tip and the relationship between crack closure stress(CCS) and crack opening displacement(COD) in the FPZ. The proposed model can simulate the actual fracture energy of experimental results fairly well. The results of the experimental data analysis show that specimen geometry and loading condition did not affect the CCS-COD relation. However, the strain energy release rate is a function of not only specimen geometry but also crack extension. The strain energy release rate remained constantly at the minimum value up to the crack extension of 25 mm, and then it increased linearly to the maximum value. The maximum fracture criterion occurred at the peak load for specimens of large size. The fracture criterion remained at the maximum value after the peak load. The variation of the fracture criterion is caused by micro-cracking and micro-crack localization. The fracture criterion of strain energy release rate can simply be the size effect of concrete fracture, and it can be used to quantify the micro-cracking and micro-crack localizing behavior of concrete.

Stabilization Characteristics of Upgraded Coal using Palm Acid Oil

  • Rifella, Archi;Chun, Dong Hyuk;Kim, Sang Do;Lee, Sihyun;Rhee, Youngwoo
    • 청정기술
    • /
    • 제22권4호
    • /
    • pp.299-307
    • /
    • 2016
  • These days, coal is one of the most important energy resources used for transportation, industry, and electricity. There are two types of coal: high-rank and low-rank. Low-rank coal has a low calorific value and contains large amounts of useless moisture. The quality of low-rank coal can be increased by simple drying technology and it needs to be stabilized by hydrocarbons (e.g. palm acid oil, PAO) to prevent spontaneous combustion and moisture re-adsorption. Spontaneous combustion becomes a major problem during coal mining, storage, and transportation. It can involve the loss of life, property, and economic value; reduce the quality of the coal; and increase greenhouse gas emissions. Besides spontaneous combustion, moisture re-adsorption also leads to a decrease in quality of the coal due to its lower heating value. In this work, PAO was used for additive to stabilize the upgraded coal. The objectives of the experiments were to determine the stabilization characteristic of coal by analyzing the behavior of upgraded coal by drying and PAO addition regarding crossing-point temperature of coal, the moisture behavior of briquette coal, and thermal decomposition behavior of coal.

Investigation of gamma radiation shielding properties of polyethylene glycol in the energy range from 8.67 to 23.19 keV

  • Akhdar, H.;Marashdeh, M.W.;AlAqeel, M.
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.701-708
    • /
    • 2022
  • The mass attenuation coefficients (μm) of polyethylene glycol (PEG) of different molecular weights (1000-200,000) were measured using single-beam photon transmission. The X-ray fluorescent (XRF) photons from Zinc (Zn), Zirconium (Zr), Molybdenum (Mo), Silver (Ag) and Cadmium (Cd) targets were used to determine the attenuation of gamma radiation of energy range between 8.67 and 23.19 keV in PEG samples. The results were compared to theoretical values using XCOM and Monte Carlo simulation using Geant4 toolkit which was developed to validate the experiment at those certain energies. The mass attenuation coefficients were then used to compute the effective atomic numbers, electron density and half value layers for the studied samples. The outcomes showed good agreement between experimental and simulated results with those calculated theoretically by XCOM within 5% deviation. The PEG 1000 sample showed slightly higher μm value compared with the other samples. The dependence of the photon energy and PEG composition on the values of μm and HVL were investigated and discussed. In addition, the values of Zeff and Neff for all PEG samples behaved similarly in the given photon energy range, and they decreased as the photon energy increased.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

소규모 전력계통에서 풍력발전의 가치 분석 (Value Analysis Of Windpower Resource in Small Scale Grid)

  • 박민혁;이재걸;윤용범
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.273-276
    • /
    • 2006
  • 신재생에너지의 효율 향상을 위한 시스템 개발과 병행하여 검토되어야 할 부문이 경제성 분석이다. 본 논문은 제주도 전력계통에 연계하여 운영중인 풍력발전의 자원과 발전량을 모의하기 위하여 제주도의 전력수요와 발전설비 특성, HDVC 수전 데이터, 풍속 등의 자료를 기반으로 가격예측을 위한 범용 소프트웨어들을 사용하여 에너지 시장 측면에서 풍력발전이 갖는 경제적 가치를 분석하였다.

  • PDF

Stability and Constant Boundary-Value Problems of f-Harmonic Maps with Potential

  • Kacimi, Bouazza;Cherif, Ahmed Mohammed
    • Kyungpook Mathematical Journal
    • /
    • 제58권3호
    • /
    • pp.559-571
    • /
    • 2018
  • In this paper, we give some results on the stability of f-harmonic maps with potential from or into spheres and any Riemannian manifold. We study the constant boundary-value problems of such maps defined on a specific Cartan-Hadamard manifolds, and obtain a Liouville-type theorem. It can also be applied to the static Landau-Lifshitz equations. We also prove a Liouville theorem for f-harmonic maps with finite f-energy or slowly divergent f-energy.