• 제목/요약/키워드: Energy Value

검색결과 6,223건 처리시간 0.034초

계측기기 측정을 통한 생활폐기물 소각시설의 에너지 회수효율 산정 연구 (Estimation of Energy Recovery Rate of Municipal Waste Incineration Facilities through Measuring Instruments)

  • 권영현;강준구;고영재;유하녕;권준화;박호연;전태완;이영기
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.770-776
    • /
    • 2018
  • This study measured the energy recovery rate of each municipal waste incineration facility according to the revised energy recovery rate estimation method, which targeted four municipal waste incineration facilities (Unit No. 7). The results calculated by the measuring instruments were used for each factor to estimate the recovery rate, and the available potential of available energy was examined by analyzing the energy production and valid consumption. As a result of the low heating value, 2,540 kcal/kg was calculated on average when the LHVw formula was applied, which is approximately 116 kcal/kg higher than the average design standard of 2,424 kcal/kg. The energy recovery rate was calculated as 96.9% on average based on production and 67.5% based on effective consumption, and the analysis shows that approximately 29.4% energy can be used.

Synchronization and identification of ship shaft power and speed for energy efficiency design index verification

  • Lee, Donchool;Barro, Ronald Dela Cruz;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.123-132
    • /
    • 2014
  • The maritime sector is advancing with dedicated endeavor to reduce greenhouse gas in addressing issues with regards to global warming. Since 01 January 2013, the International Maritime Organization (IMO) regulation mandatory requirement for Energy Efficiency Design Index (EEDI) has been in place and should be satisfied by newly-built ships of more than 400 gross tonnage and the Ship Energy Efficiency Management Plan (SEEMP) for all ships type. Therefore, compliance to this necessitates planning during the design stage whereas verification can be carried-out through an acceptable method during sea trial. The MEPC-approved 2013 guidance, ISO 15016 and ISO 19019 on EEDI serves the purpose for calculation and verification of attained EEDI value. Individual ships EEDI value should be lower than the required value set by these regulations. The key factors for EEDI verification are power and speed assessment and their synchronization. The shaft power can be measured by telemeter system using strain gage during sea trial. However, calibration of shaft power onboard condition is complicated. Hence, it relies only on proficient technology that operates within the permitted ISO allowance. On the other hand, the ship speed can be measured and calibrated by differential ground positioning system (DGPS). An actual test on a newly-built vessel was carried out to assess the correlation of power and speed. The Energy-efficiency Design Index or Operational Indicator Monitoring System (EDiMS) software developed by the Dynamics Laboratory-Mokpo Maritime University (DL-MMU) and Green Marine Equipment RIS Center (GMERC) of Mokpo Maritime University was utilized for this investigation. In addition, the software can continuously monitor air emission and is a useful tool for inventory and ship energy management plan. This paper introduces the synchronization and identification method between shaft power and ship speed for EEDI verification in accordance with the ISO guidance.

우드칩 바이오매스를 이용한 열병합발전 운영 사례 분석 (Case Study and Evaluation of Economic Feasibility of Combined Heat and Power System using Woodchip Biomass)

  • 서길영;김성현
    • 신재생에너지
    • /
    • 제8권4호
    • /
    • pp.21-29
    • /
    • 2012
  • The extensible supply of New & Renewable energy resources desperately needs to counter the high dependence on imported energy, recent high oil prices and the Climate Change Conference, and the government has operated the 'Renewable Portfolio Standard' (RPS) as one of the renewable energy policy from 2012. By analyzing the operation case of combined heat and power plant using the woodchip biomass, we drew the price of wood chip fuel, plant capacity factor, electricity selling price, heat selling price and LCOE value. After analyzing the economic feasibility of 3MWe combined heat and power plant based on the operating performance, the minimum of economic feasibility has appeared to be secured according to the internal rate of return (IRR) is 6.34% and the net present value (NPV) is 3.6 billion won as of 20 years life time after installation, and after analyzing the cases of the economic feasibility of the price of wood chip, plant capacity factor, electricity and heat selling price are changed, the economic feasibility is valuable when the price of wood chip is over 64,000 won/ton, NPV is minus, and the capacity factor is above 46.9%, the electricity selling price is 116 won/kWh and the heat selling price is above 75,600 won/Gcal. When going over the new installation hereafter, we need the detailed review of the woodchip storage and woodchip feeding system rather than the steam-turbine and boiler which have been inspected many times, the reason why is it's hard to secure the suitable quality (constant size) of woodchip by the lack of understanding about it as a fuel because of the domestic poor condition and the calorific value of woodchip is seriously volatile compared with other fuels.

CT X-선 빔들의 유효에너지 결정 (Determination of Effective Energy of CT X-ray beams)

  • 김종언
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.517-522
    • /
    • 2019
  • 이 연구의 목적은 AAPM CT 성능 팬텀 안에 있는 CT 수 교정 삽입부의 CT 슬라이스 영상들을 사용하여 CT X-선 빔들의 유효에너지를 결정하는데 있다. AAPM CT 성능 팬텀의 CT 수 교정 삽입부는 80, 100, 120 kVp X-선 빔에 대하여 CT 스캐너로 5번 스캔되었다. 각 핀의 CT 수는 각각의 CT 슬라이스 영상에 대하여 측정되었다. 상관계수들은 각 핀에서 측정된 CT 수의 평균값과 미국표준기술연구소의 자료로부터 계산된 다른 광자에너지 하에 선감약계수를 선형정합하여 얻었다. 얻어진 상관계수의 최대값에 대응하는 광자에너지는 유효에너지로 결정하였다. 결과로서, 유효에너지는 80, 100, 120 kVp X-선 빔들에 대하여 각각 56, 62, 66~67 keV이다.

Energy-Efficient Routing Protocol for Wireless Sensor Networks Based on Improved Grey Wolf Optimizer

  • Zhao, Xiaoqiang;Zhu, Hui;Aleksic, Slavisa;Gao, Qiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권6호
    • /
    • pp.2644-2657
    • /
    • 2018
  • To utilize the energy of sensor nodes efficiently and extend the network lifetime maximally is one of the primary goals in wireless sensor networks (WSNs). Thus, designing an energy-efficient protocol to optimize the determination of cluster heads (CHs) in WSNs has become increasingly important. In this paper, we propose a novel energy-efficient protocol based on an improved Grey Wolf Optimizer (GWO), which we refer to as Fitness value based Improved GWO (FIGWO). It considers a fitness value to improve the finding of the optimal solution in GWO, which ensures a better distribution of CHs and a more balanced cluster structure. According to the distance to the CHs and the BS, sensor nodes' transmission distance are recalculated to reduce the energy consumption. Simulation results demonstrate that the proposed approach can prolong the stability period of the network in comparison to other algorithms, namely by 31.5% in comparison to SEP, and even by 57.8% when compared with LEACH protocol. The results also show that the proposed protocol performs well over the above comparative protocols in terms of energy consumption and network throughput.

점용접된 판에서의 동적 파괴 거동 (Dynamic Fracture Behavior at the Spot Welding Plate)

  • 조재웅
    • 한국산학기술학회논문지
    • /
    • 제7권3호
    • /
    • pp.314-318
    • /
    • 2006
  • 본 연구에서는 점 용접된 박판이 파괴되어 가는 동적 과정을 시뮬레이션 함으로서 그 점용접부의 강도를 해석하는데 있다. 위판이 아래의 판에 대하여 늘어난 후 0.64 ms가 경과된 시점에서 서로 점 용접된 위판 및 아래 판이 떨어져 나감을 알 수 있다. 비교적 위판 및 아래 판 가운데의 용접 부위에서 최대의 von Mises 응력을 나타내고 있다. 용접이 깨어지는 시점인 0.64 ms 부근에서는 그 내부에너지가 상당히 감소되고 운동에너지는 급격히 증가됨을 알 수 있다. 미끄럼 에너지는 시간이 경과됨에 따라 계단형으로 감소되어 경과 시간이 0.2 ms 부근에서 0이 되다가 그 후로는 미끄럼 에너지가 음수의 값이 되어 두 판들은 오히려 고착이 되는 것을 알 수 있다.

  • PDF

태양광발전단지 건설을 위한 태양광자원 정밀조사 (A Detailed Survey on the Solar Availability for the Construction of Photovoltaic Power Generation Sites)

  • 조덕기;강용혁;이의준;오정무
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.83-88
    • /
    • 2004
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar photovoltaic system users as well as by research institutes From the results, we can conclude that 1) The yearly averaged horizontal global insolation of Korea was turned out $3.57kWh/m^2.day$ in the periods of $1982\sim2001$. 2) Horizontal global insolation of spring and summer was respectively 24 % and 21 % higher than the yearly average value, and that of fall and winter was respectively 12 % and 34 % lower than the yearly average value.

바이오에탄올 생산을 위한 바이오매스 자원으로서 버섯골목의 이용 가능성 평가 (Evaluation on the utilization possibility of waste mushroom logs as biomass resource for bioethanol production)

  • 이재원;구본욱;최준원;최돈하;최인규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.485-488
    • /
    • 2006
  • In order to investigate the possibility of waste mushroom logs as biomass resource chemical and physical characteristics of normal woods and waste mushroom logs such as crystallinity value, energy consumption, total sugar yield after hydrolysis chemical compounds and molecular weight distribution after acid hydrolysis, were examined. In the results, crystallinity of waste mushroom logs which were three year passed after the inoculation was decreased drastically from 49% to 33% during the cultivation. Lignin contents as chemical compounds of normal woods and waste mushroom logs were 21.07% and 18.78%, respectively. By the results of measurement of energy consumption, the size reduction of normal woods required a significantly higher energy than that of waste mushroom logs. In the hydrolysis, total sugar yield by enzyme and acid hydrolysis were high in waste mushroom logs(53% 57.5%) than in normal woods(42.9%, 47.17%). According to the molecular weight distribution using GPC, low molecular weight compounds were distributed in waste mushroom logs. Based on these results, waste mushroom logs have enough potential as material for developing alternative energy because of easily conversion to sugar by various hydrolysis methods and requirement of low energy consumption during size reduction.

  • PDF

풍력발전단지의 후류손실 및 터빈 재배치에 관한 연구 (Wake Losses and Repositioning of Wind Turbines at Wind Farm)

  • 박근성;유기완;김현구
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.17-25
    • /
    • 2015
  • The main objective of this study is to predict the wind power generation at the wind farm using various wake models. Modeling of wind farm is a prerequisite for prediction of annual energy production at the wind farm. In this study, we modeled 20 MW class Seongsan wind farm which has 10 wind turbines located at the eastern part of Jeju Island. WindSim based on the computational fluid dynamics was adopted for the estimation of power generation. The power curve and thrust coefficient with meteorology file were prepared for wind farm modelling. The meteorology file was produced based on the measured data of the Korea Wind Atlas provided by Korea Institute of Energy Research. Three types of wake models such as Jensen, Larsen, and Ishihara et al. wake models were applied to investigate the wake effects. From the result, Jensen and Ishihara wake models show nearly the same value of power generation whereas the Larsen wake model shows the largest value. New positions of wind turbines are proposed to reduce the wake loss, and to increase the annual energy production of the wind farm.

STPV의 건물 에너지 성능에 대한 파라메트릭 분석 (Parametric Analysis of Building Energy Impact of Semi-transparent PV)

  • 곽인규;문선혜;허정호
    • 대한건축학회논문집:구조계
    • /
    • 제34권7호
    • /
    • pp.35-42
    • /
    • 2018
  • Semi-transparent Photovoltaics (STPV) works as an exterior material replacing windows as well as functioning as a electricity generator. As a result, it also affects the building's heating, cooling and lighting loads. In this study, we used the concept of Net Electricity Benefit(NEB) to conduct a parametric analysis of building energy impact of STPV. The NEB of STPV is from $-1kWh/m^2$ to $6kWh/m^2$. Since NEB represents the amount of energy increase or decrease when STPV is applied compared to the standard window, a value of 0 or less means that the demand for building energy can be increased rather than applying a general window having high thermal performance and high visible light transmittance value. Therefore, it is necessary to perform a comprehensive performance evaluation considering both the performance evaluation based on the existing power generation performance and the influence on the building energy.